11 research outputs found

    Clinical parameters and tools for home-based assessment of Parkinson’s disease: results from a Delphi study

    Get PDF
    © 2015 – IOS Press and the authors. All rights reserved. This article is published online with Open Access and distributed under the terms of the Creative Commons Attribution Non-Commercial License.Background: Parkinson's disease (PD) is a neurodegenerative disorder with fluctuating symptoms. To aid the development of a system to evaluate people with PD (PwP) at home (SENSE-PARK system) there was a need to define parameters and tools to be applied in the assessment of 6 domains: gait, bradykinesia/hypokinesia, tremor, sleep, balance and cognition. Objective: To identify relevant parameters and assessment tools of the 6 domains, from the perspective of PwP, caregivers and movement disorders specialists. Methods: A 2-round Delphi study was conducted to select a core of parameters and assessment tools to be applied. This process included PwP, caregivers and movement disorders specialists. Results: Two hundred and thirty-three PwP, caregivers and physicians completed the first round questionnaire, and 50 the second. Results allowed the identification of parameters and assessment tools to be added to the SENSE-PARK system. The most consensual parameters were: Falls and Near Falls; Capability to Perform Activities of Daily Living; Interference with Activities of Daily Living; Capability to Process Tasks; and Capability to Recall and Retrieve Information. The most cited assessment strategies included Walkers; the Evaluation of Performance Doing Fine Motor Movements; Capability to Eat; Assessment of Sleep Quality; Identification of Circumstances and Triggers for Loose of Balance and Memory Assessment. Conclusions: An agreed set of measuring parameters, tests, tools and devices was achieved to be part of a system to evaluate PwP at home. A pattern of different perspectives was identified for each stakeholder.info:eu-repo/semantics/publishedVersio

    Erratum to: A systematic review of the characteristics and validity of monitoring technologies to assess Parkinson’s disease

    Get PDF
    This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated."Background: There is growing interest in having objective assessment of health-related outcomes using technology-based devices that provide unbiased measurements which can be used in clinical practice and scientific research. Many studies have investigated the clinical manifestations of Parkinson’s disease using such devices. However, clinimetric properties and clinical validation vary among the different devices. Methods: Given such heterogeneity, we sought to perform a systematic review in order to (i) list, (ii) compare and (iii) classify technological-based devices used to measure motor function in individuals with Parkinson's disease into three groups, namely wearable, non-wearable and hybrid devices. A systematic literature search of the PubMed database resulted in the inclusion of 168 studies. These studies were grouped based on the type of device used. For each device we reviewed availability, use, reliability, validity, and sensitivity to change. The devices were then classified as (i) ‘recommended’, (ii) ‘suggested’ or (iii) ‘listed’ based on the following criteria: (1) used in the assessment of Parkinson’s disease (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). Results: Seventy-three devices were identified, 22 were wearable, 38 were non-wearable, and 13 were hybrid devices. In accordance with our classification method, 9 devices were ‘recommended’, 34 devices were ‘suggested’, and 30 devices were classified as ‘listed’. Within the wearable devices group, the Mobility Lab sensors from Ambulatory Parkinson’s Disease Monitoring (APDM), Physilog®, StepWatch 3, TriTrac RT3 Triaxial accelerometer, McRoberts DynaPort, and Axivity (AX3) were classified as ‘recommended’. Within the non-wearable devices group, the Nintendo Wii Balance Board and GAITRite® gait analysis system were classified as ‘recommended’. Within the hybrid devices group only the Kinesia® system was classified as ‘recommended’."The present research is part of the EU project SENSE-PARK, funded under the Seventh Framework Programme, Cooperation – ICT, Grant Agreement no. 288557

    The German National Registry of Primary Immunodeficiencies (2012-2017)

    Get PDF
    Introduction: The German PID-NET registry was founded in 2009, serving as the first national registry of patients with primary immunodeficiencies (PID) in Germany. It is part of the European Society for Immunodeficiencies (ESID) registry. The primary purpose of the registry is to gather data on the epidemiology, diagnostic delay, diagnosis, and treatment of PIDs. Methods: Clinical and laboratory data was collected from 2,453 patients from 36 German PID centres in an online registry. Data was analysed with the software Stata® and Excel. Results: The minimum prevalence of PID in Germany is 2.72 per 100,000 inhabitants. Among patients aged 1–25, there was a clear predominance of males. The median age of living patients ranged between 7 and 40 years, depending on the respective PID. Predominantly antibody disorders were the most prevalent group with 57% of all 2,453 PID patients (including 728 CVID patients). A gene defect was identified in 36% of patients. Familial cases were observed in 21% of patients. The age of onset for presenting symptoms ranged from birth to late adulthood (range 0–88 years). Presenting symptoms comprised infections (74%) and immune dysregulation (22%). Ninety-three patients were diagnosed without prior clinical symptoms. Regarding the general and clinical diagnostic delay, no PID had undergone a slight decrease within the last decade. However, both, SCID and hyper IgE- syndrome showed a substantial improvement in shortening the time between onset of symptoms and genetic diagnosis. Regarding treatment, 49% of all patients received immunoglobulin G (IgG) substitution (70%—subcutaneous; 29%—intravenous; 1%—unknown). Three-hundred patients underwent at least one hematopoietic stem cell transplantation (HSCT). Five patients had gene therapy. Conclusion: The German PID-NET registry is a precious tool for physicians, researchers, the pharmaceutical industry, politicians, and ultimately the patients, for whom the outcomes will eventually lead to a more timely diagnosis and better treatment

    Kalibrierung und Implementierung eines Laserprojektors als Autopointer

    Get PDF
    Die vorliegende Arbeit beschreibt die Kalibrierung und Implementierung eines Laserprojektors als Autopointer. Ziel ist es, mit Hilfe eines Pico Laserprojektors herkömmliche Augmented Reality Methoden durch Projektion in die reale Welt zu erweitern. Es soll ein “Autopointer“ implementiert werden, der Informationen auf bekannte Oberflächen projiziert. Dabei muss ständig die 6D-Lage des Autopointers gemessen werden. Die Projektion wird entgegen der erfassten Bewegung nachgeführt, so dass das Bild ortsfest auf dem Objekt verbleibt. Das System soll u.a. im medizintechnischen Bereich Verwendung finden, z.B. um präoperativ geplante Einstiche anzuzeigen. Um die Verzeichnungserscheinungen des Laserprojektors auszugleichen, wurden verschieden Projektionen mit Hilfe einer kalibrierten Messkamera aufgenommen und unter Verwendung des homographischen Zusammenhangs ausgewertet. Diese Vorgehensweise hat sich als sehr schnell und effektiv erwiesen und ergab eine subpixelgenaue Beschreibung des Abbildungsverhaltens. Die Untersuchung der Projektionseigenschaften des Autopointers liefert vielversprechende Ergebnisse

    Quantitative home-based assessment of Parkinson’s symptoms: The SENSE-PARK feasibility and usability study

    Get PDF
    Published version, also available at http://dx.doi.org/10.1186/s12883-015-0343-zBackground: Currently, assessment of symptoms associated with Parkinson’s disease is mainly performed in the clinic. However, these assessments have limitations because they provide only a snapshot of the condition. Methods: The feasibility and usability of an objective, continuous and relatively unobtrusive system (SENSE-PARK System), which consists of wearable sensors (three worn during the day and one worn at night), a smartphone-based App, a balance board and computer software, was tested 24/7 over 12 weeks in a study including 22 PD patients. During the first four weeks of the study, patients did not get feedback about their performance, during the last eight weeks they did. The study included seven clinical visits with standardized interviews, and regular phone contact. The primary outcome was the number of drop-outs during the study. As secondary outcomes, the Post-Study System Usability Questionnaire (PSSUQ), score and information obtained from the standardized interviews were used to evaluate the usability of the system. Results: All patients completed the study. The participants rated the usability of the SENSE-PARK System with a mean score of 2.67 (±0.49) on the PSSUQ. The interviews revealed that most participants liked using the system and appreciated that it signaled changes in their health condition. Conclusions: This 12 week controlled study demonstrates that the acceptance level of PD patients using the SENSE-PARK System as a home-based 24/7 assessment is very good. Particular emphasis should be given to a user-friendly design. Motivation to wear such a system can be increased by providing direct feedback about the individual health condition

    The effect of spironolactone on diastolic function in haemodialysis patients

    No full text
    Heart failure with preserved ejection fraction (HFpEF) is highly prevalent in patients on maintenance haemodialysis (HD) and lacks effective treatment. We investigated the effect of spironolactone on cardiac structure and function with a specific focus on diastolic function parameters. The MiREnDa trial examined the effect of 50 mg spironolactone once daily versus placebo on left ventricular mass index (LVMi) among 97 HD patients during 40 weeks of treatment. In this echocardiographic substudy, diastolic function was assessed using predefined structural and functional parameters including E/e'. Changes in the frequency of HFpEF were analysed using the comprehensive 'HFA-PEFF score'. Complete echocardiographic assessment was available in 65 individuals (59.5 ± 13.0 years, 21.5% female) with preserved left ventricular ejection fraction (LVEF > 50%). At baseline, mean E/e' was 15.2 ± 7.8 and 37 (56.9%) patients fulfilled the criteria of HFpEF according to the HFA-PEFF score. There was no significant difference in mean change of E/e' between the spironolactone group and the placebo group (+ 0.93 ± 5.39 vs. + 1.52 ± 5.94, p = 0.68) or in mean change of left atrial volume index (LAVi) (1.9 ± 12.3 ml/
    corecore