221 research outputs found

    Development and didactic analysis of smartphone-based experimental exercises for the smart physics lab

    Get PDF
    homework problems in an introductory mechanics course at a university. A quasi-experimental field study with two cohorts design was performed to measure the impact of such exercises on motivation, interest and conceptual understanding. The empirical results on learning achievement show a significant positive influence of the smartphone-based experimental exercise for the dynamics of rigid bodies topic with a medium effect size of d =0.42. For the analysis of rotational motion topic, a positive learning achievement for both groups was evidenced, but the effect size of the smartphone-based exercise was rather small at d =0.20 . The intrinsic and germane cognitive loads turned out to be similar at an intermediate level for both groups. However, the extrinsic cognitive load for the intervention group decreased significantly, which might be the reason why more complex experimental exercises foster conceptual understanding

    Self-diffusion of polymers in cartilage as studied by pulsed field gradient NMR

    Get PDF
    Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) was used to investigate the self-diffusion behaviour of polymers in cartilage. Polyethylene glycol and dextran with different molecular weights and in different concentrations were used as model compounds to mimic the diffusion behaviour of metabolites of cartilage. The polymer self-diffusion depends extremely on the observation time: The short-time self-diffusion coefficients (diffusion time Delta approximately 15 ms) are subjected to a rather non-specific obstruction effect that depends mainly on the molecular weights of the applied polymers as well as on the water content of the cartilage. The observed self-diffusion coefficients decrease with increasing molecular weights of the polymers and with a decreasing water content of the cartilage. In contrast, the long-time self-diffusion coefficients of the polymers in cartilage (diffusion time Delta approximately 600 ms) reflect the structural properties of the tissue. Measurements at different water contents, different molecular weights of the polymers and varying observation times suggest that primarily the collagenous network of cartilage but also the entanglements of the polymer chains themselves are responsible for the observed restricted diffusion. Additionally, anomalous restricted diffusion was shown to occur already in concentrated polymer solutions

    Faecal Matrix Metalloprotease-9 Is a More Sensitive Marker For Diagnosing Pouchitis Than Faecal Calprotectin – Results From a Pilot Study

    Get PDF
    Background. Potential non-invasive markers of pouchitis would have a great deal of significance within clinical practice. This study is aimed at assessing the diagnostic accuracy of faecal calprotectin and matrix metalloprotease-9 as potential markers in patients both with and without pouchitis. Patients and methods. Stool and blood samples were collected from 33 ileal pouch-anal anastomosis patients before a follow-up pouchoscopy. Biopsy samples were taken for histological purposes. The presence of cuffitis and stenosis was evaluated with an endoscopy. Calprotectin and matrix metalloprotease-9 were quantified with an enzyme-linked immunosorbent assay. Results. Pouchitis was detected in 30.3% of the patients. The levels of faecal calprotectin and matrix metalloprotease-9 increased significantly in patients with pouchitis. The sensitivity and specificity of matrix metalloprotease-9 was higher than that of faecal calprotectin. Only matrix metalloprotease-9 correlated significantly with the severity of pouchitis. Conclusions. Faecal matrix metalloprotease-9 has a high specificity in the diagnosis of pouchitis

    Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis.

    Get PDF
    BACKGROUND Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA. AIM To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS. METHODS Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded. RESULTS At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month. CONCLUSIONS The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions. https://clinicaltrials.gov/ct2/show/NCT01532427

    Ustekinumab as Induction and Maintenance Therapy for Crohn’s Disease

    Get PDF
    BACKGROUND Ustekinumab, a monoclonal antibody to the p40 subunit of interleukin-12 and inter-leukin-23, was evaluated as an intravenous induction therapy in two populations with moderately to severely active Crohn’s disease. Ustekinumab was also evaluated as subcutaneous maintenance therapy. METHODS We randomly assigned patients to receive a single intravenous dose of ustekinumab (either 130 mg or approximately 6 mg per kilogram of body weight) or placebo in two induction trials. The UNITI-1 trial included 741 patients who met the criteria for primary or secondary nonresponse to tumor necrosis factor (TNF) antagonists or had unacceptable side effects. The UNITI-2 trial included 628 patients in whom conventional therapy failed or unacceptable side effects occurred. Patients who completed these induction trials then participated in IM-UNITI, in which the 397 patients who had a response to ustekinumab were randomly assigned to receive subcutaneous maintenance injections of 90 mg of ustekinumab (either every 8 weeks or every 12 weeks) or placebo. The primary end point for the induction trials was a clinical response at week 6 (defined as a decrease from baseline in the Crohn’s Disease Activity Index [CDAI] score of ≥100 points or a CDAI score <150). The primary end point for the maintenance trial was remission at week 44 (CDAI score <150). RESULTS The rates of response at week 6 among patients receiving intravenous ustekinumab at a dose of either 130 mg or approximately 6 mg per kilogram were significantly higher than the rates among patients receiving placebo (in UNITI-1, 34.3%, 33.7%, and 21.5%, respectively, with P≤0.003 for both comparisons with placebo; in UNITI-2, 51.7%, 55.5%, and 28.7%, respectively, with P<0.001 for both doses). In the groups receiving maintenance doses of ustekinumab every 8 weeks or every 12 weeks, 53.1% and 48.8%, respectively, were in remission at week 44, as compared with 35.9% of those receiving placebo (P = 0.005 and P = 0.04, respectively). Within each trial, adverse-event rates were similar among treatment groups. CONCLUSIONS Among patients with moderately to severely active Crohn’s disease, those receiving intravenous ustekinumab had a significantly higher rate of response than did those receiving placebo. Subcutaneous ustekinumab maintained remission in patients who had a clinical response to induction therapy. (Funded by Janssen Research and Development; ClinicalTrials.gov numbers, NCT01369329, NCT01369342, and NCT01369355.

    Direct observation of ion dynamics in supercapacitor electrodes using in situ diffusion NMR spectroscopy

    Get PDF
    Ionic transport inside porous carbon electrodes underpins the storage of energy in supercapacitors and the rate at which they can charge and discharge, yet few studies have elucidated the materials properties that influence ion dynamics. Here we use in situ pulsed field gradient NMR spectroscopy to measure ionic diffusion in supercapacitors directly. We find that confinement in the nanoporous electrode structures decreases the effective self-diffusion coefficients of ions by over two orders of magnitude compared with neat electrolyte, and in-pore diffusion is modulated by changes in ion populations at the electrode/electrolyte interface during charging. Electrolyte concentration and carbon pore size distributions also affect in-pore diffusion and the movement of ions in and out of the nanopores. In light of our findings we propose that controlling the charging mechanism may allow the tuning of the energy and power performances of supercapacitors for a range of different applications

    Development and didactic analysis of smartphone-based experimental exercises for the smart physics lab

    No full text
    homework problems in an introductory mechanics course at a university. A quasi-experimental field study with two cohorts design was performed to measure the impact of such exercises on motivation, interest and conceptual understanding. The empirical results on learning achievement show a significant positive influence of the smartphone-based experimental exercise for the dynamics of rigid bodies topic with a medium effect size of d =0.42. For the analysis of rotational motion topic, a positive learning achievement for both groups was evidenced, but the effect size of the smartphone-based exercise was rather small at d =0.20 . The intrinsic and germane cognitive loads turned out to be similar at an intermediate level for both groups. However, the extrinsic cognitive load for the intervention group decreased significantly, which might be the reason why more complex experimental exercises foster conceptual understanding
    • …
    corecore