213 research outputs found

    739 observed NEAs and new 2-4m survey statistics within the EURONEAR network

    Full text link
    We report follow-up observations of 477 program Near-Earth Asteroids (NEAs) using nine telescopes of the EURONEAR network having apertures between 0.3 and 4.2 m. Adding these NEAs to our previous results we now count 739 program NEAs followed-up by the EURONEAR network since 2006. The targets were selected using EURONEAR planning tools focusing on high priority objects. Analyzing the resulting orbital improvements suggests astrometric follow-up is most important days to weeks after discovery, with recovery at a new opposition also valuable. Additionally we observed 40 survey fields spanning three nights covering 11 sq. degrees near opposition, using the Wide Field Camera on the 2.5m Isaac Newton Telescope (INT), resulting in 104 discovered main belt asteroids (MBAs) and another 626 unknown one-night objects. These fields, plus program NEA fields from the INT and from the wide field MOSAIC II camera on the Blanco 4m telescope, generated around 12,000 observations of 2,000 minor planets (mostly MBAs) observed in 34 square degrees. We identify Near Earth Object (NEO) candidates among the unknown (single night) objects using three selection criteria. Testing these criteria on the (known) program NEAs shows the best selection methods are our epsilon-miu model which checks solar elongation and sky motion and the MPC's NEO rating tool. Our new data show that on average 0.5 NEO candidates per square degree should be observable in a 2m-class survey (in agreement with past results), while an average of 2.7 NEO candidates per square degree should be observable in a 4m-class survey (although our Blanco statistics were affected by clouds). At opposition just over 100 MBAs (1.6 unknown to every 1 known) per square degree are detectable to R=22 in a 2m survey based on the INT data, while our two best ecliptic Blanco fields away from opposition lead to 135 MBAs (2 unknown to every 1 known) to R=23.Comment: Published in Planetary and Space Sciences (Sep 2013

    The GALFA-HI Compact Cloud Catalog

    Full text link
    We present a catalog of 1964 isolated, compact neutral hydrogen clouds from the Galactic Arecibo L-Band Feed Array Survey Data Release One (GALFA-HI DR1). The clouds were identified by a custom machine-vision algorithm utilizing Difference of Gaussian kernels to search for clouds smaller than 20'. The clouds have velocities typically between |VLSR| = 20-400 km/s, linewidths of 2.5-35 km/s, and column densities ranging from 1 - 35 x 10^18 cm^-2. The distances to the clouds in this catalog may cover several orders of magnitude, so the masses may range from less than a Solar mass for clouds within the Galactic disc, to greater than 10^4 Solar Masses for HVCs at the tip of the Magellanic Stream. To search for trends, we separate the catalog into five populations based on position, velocity, and linewidth: high velocity clouds (HVCs); galaxy candidates; cold low velocity clouds (LVCs); warm, low positive-velocity clouds in the third Galactic Quadrant; and the remaining warm LVCs. The observed HVCs are found to be associated with previously-identified HVC complexes. We do not observe a large population of isolated clouds at high velocities as some models predict. We see evidence for distinct histories at low velocities in detecting populations of clouds corotating with the Galactic disc and a set of clouds that is not corotating.Comment: 34 Pages, 9 Figures, published in ApJ (2012, ApJ, 758, 44), this version has the corrected fluxes and corresponding flux histogram and masse

    ImageParser: a tool for finite element generation from three-dimensional medical images

    Get PDF
    BACKGROUND: The finite element method (FEM) is a powerful mathematical tool to simulate and visualize the mechanical deformation of tissues and organs during medical examinations or interventions. It is yet a challenge to build up an FEM mesh directly from a volumetric image partially because the regions (or structures) of interest (ROIs) may be irregular and fuzzy. METHODS: A software package, ImageParser, is developed to generate an FEM mesh from 3-D tomographic medical images. This software uses a semi-automatic method to detect ROIs from the context of image including neighboring tissues and organs, completes segmentation of different tissues, and meshes the organ into elements. RESULTS: The ImageParser is shown to build up an FEM model for simulating the mechanical responses of the breast based on 3-D CT images. The breast is compressed by two plate paddles under an overall displacement as large as 20% of the initial distance between the paddles. The strain and tangential Young's modulus distributions are specified for the biomechanical analysis of breast tissues. CONCLUSION: The ImageParser can successfully exact the geometry of ROIs from a complex medical image and generate the FEM mesh with customer-defined segmentation information

    280 one-opposition near-Earth asteroids recovered by the EURONEAR with the <i>Isaac Newton</i> Telescope

    Get PDF
    Context. One-opposition near-Earth asteroids (NEAs) are growing in number, and they must be recovered to prevent loss and mismatch risk, and to improve their orbits, as they are likely to be too faint for detection in shallow surveys at future apparitions. Aims. We aimed to recover more than half of the one-opposition NEAs recommended for observations by the Minor Planet Center (MPC) using the Isaac Newton Telescope (INT) in soft-override mode and some fractions of available D-nights. During about 130 h in total between 2013 and 2016, we targeted 368 NEAs, among which 56 potentially hazardous asteroids (PHAs), observing 437 INT Wide Field Camera (WFC) fields and recovering 280 NEAs (76% of all targets). Methods. Engaging a core team of about ten students and amateurs, we used the THELI, Astrometrica, and the Find_Orb software to identify all moving objects using the blink and track-and-stack method for the faintest targets and plotting the positional uncertainty ellipse from NEODyS. Results. Most targets and recovered objects had apparent magnitudes centered around V ~ 22.8 mag, with some becoming as faint as V ~ 24 mag. One hundred and three objects (representing 28% of all targets) were recovered by EURONEAR alone by Aug. 2017. Orbital arcs were prolonged typically from a few weeks to a few years; our oldest recoveries reach 16 years. The O−C residuals for our 1854 NEA astrometric positions show that most measurements cluster closely around the origin. In addition to the recovered NEAs, 22 000 positions of about 3500 known minor planets and another 10 000 observations of about 1500 unknown objects (mostly main-belt objects) were promptly reported to the MPC by our team. Four new NEAs were discovered serendipitously in the analyzed fields and were promptly secured with the INT and other telescopes, while two more NEAs were lost due to extremely fast motion and lack of rapid follow-up time. They increase the counting to nine NEAs discovered by the EURONEAR in 2014 and 2015. Conclusions. Targeted projects to recover one-opposition NEAs are efficient in override access, especially using at least two-meter class and preferably larger field telescopes located in good sites, which appear even more efficient than the existing surveys

    Data-Driven Phenotyping of Central Disorders of Hypersomnolence With Unsupervised Clustering

    Get PDF
    Background and ObjectivesRecent studies fueled doubts as to whether all currently defined central disorders of hypersomnolence are stable entities, especially narcolepsy type 2 and idiopathic hypersomnia. New reliable biomarkers are needed, and the question arises of whether current diagnostic criteria of hypersomnolence disorders should be reassessed. The main aim of this data-driven observational study was to see whether data-driven algorithms would segregate narcolepsy type 1 and identify more reliable subgrouping of individuals without cataplexy with new clinical biomarkers.MethodsWe used agglomerative hierarchical clustering, an unsupervised machine learning algorithm, to identify distinct hypersomnolence clusters in the large-scale European Narcolepsy Network database. We included 97 variables, covering all aspects of central hypersomnolence disorders such as symptoms, demographics, objective and subjective sleep measures, and laboratory biomarkers. We specifically focused on subgrouping of patients without cataplexy. The number of clusters was chosen to be the minimal number for which patients without cataplexy were put in distinct groups.ResultsWe included 1,078 unmedicated adolescents and adults. Seven clusters were identified, of which 4 clusters included predominantly individuals with cataplexy. The 2 most distinct clusters consisted of 158 and 157 patients, were dominated by those without cataplexy, and among other variables, significantly differed in presence of sleep drunkenness, subjective difficulty awakening, and weekend-week sleep length difference. Patients formally diagnosed as having narcolepsy type 2 and idiopathic hypersomnia were evenly mixed in these 2 clusters.DiscussionUsing a data-driven approach in the largest study on central disorders of hypersomnolence to date, our study identified distinct patient subgroups within the central disorders of hypersomnolence population. Our results contest inclusion of sleep-onset REM periods in diagnostic criteria for people without cataplexy and provide promising new variables for reliable diagnostic categories that better resemble different patient phenotypes. Cluster-guided classification will result in a more solid hypersomnolence classification system that is less vulnerable to instability of single features

    Gold Nanoparticles Generated in Ethosome Bilayers, As Revealed by Cryo-Electron-Tomography

    Full text link
    Gold nanoparticles have been synthesized inside ethosomes, vesicles composed of phospholipid, ethanol and water, which could be very efficient not only in delivery probes to the skin but also as diagnostic and therapeutic multimodal agents. High efficiency encapsulation of gold nanoparticles is achieved by a simple strategy: the nanoparticles synthesis occurs simultaneously with the ethosomes formation, in the absence of any undesirable reducing agents. A three-dimensional reconstruction of a gold-embedded ethosome generated by cryoelectron tomography reveals that the gold particle is localized inside the lipid bilayer, leaving the ethosome surface and core free for further functionalization. The resulting gold nanoparticles are homogeneous in size and shape and, depending on synthesis temperature, the size ranges from 10 to 20 nm, as revealed by TEM. The ethosome-nanoparticles hybrids size has been investigated by means of dynamic light scattering and has been found to vary with temperature and gold salt concentration from 700 to 400 nm. Gold nanoparticles encapsulated ethosomes offer a versatile platform for the enhancement of pharmacological efficacy in transdermal and dermal delivery systems.Comment: 2 videos of the cryo-electron tomographic reconstruction in Supporting Informatio

    On‐Demand Reconfiguration of Nanomaterials: When Electronics Meets Ionics

    Full text link
    Rapid advances in the semiconductor industry, driven largely by device scaling, are now approaching fundamental physical limits and face severe power, performance, and cost constraints. Multifunctional materials and devices may lead to a paradigm shift toward new, intelligent, and efficient computing systems, and are being extensively studied. Herein examines how, by controlling the internal ion distribution in a solid‐state film, a material’s chemical composition and physical properties can be reversibly reconfigured using an applied electric field, at room temperature and after device fabrication. Reconfigurability is observed in a wide range of materials, including commonly used dielectric films, and has led to the development of new device concepts such as resistive random‐access memory. Physical reconfigurability further allows memory and logic operations to be merged in the same device for efficient in‐memory computing and neuromorphic computing systems. By directly changing the chemical composition of the material, coupled electrical, optical, and magnetic effects can also be obtained. A survey of recent fundamental material and device studies that reveal the dynamic ionic processes is included, along with discussions on systematic modeling efforts, device and material challenges, and future research directions.By controlling the internal ion distribution in a solid‐state film, the material’s chemical composition and physical (i.e., electrical, optical, and magnetic) properties can be reversibly reconfigured, in situ, using an applied electric field. The reconfigurability is achieved in a wide range of materials, and can lead to the development of new memory, logic, and multifunctional devices and systems.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/141225/1/adma201702770.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/141225/2/adma201702770_am.pd

    Flow mediated dilation of the brachial artery: an investigation of methods requiring further standardization

    Get PDF
    BACKGROUND: In order to establish a consistent method for brachial artery reactivity assessment, we analyzed commonly used approaches to the test and their effects on the magnitude and time-course of flow mediated dilation (FMD), and on test variability and repeatability. As a popular and noninvasive assessment of endothelial function, several different approaches have been employed to measure brachial artery reactivity with B-mode ultrasound. Despite some efforts, there remains a lack of defined normal values and large variability in measurement technique. METHODS: Twenty-six healthy volunteers underwent repeated brachial artery diameter measurements by B-mode ultrasound. Following baseline diameter recordings we assessed endothelium-dependent flow mediated dilation by inflating a blood pressure cuff either on the upper arm (proximal) or on the forearm (distal). RESULTS: Thirty-seven measures were performed using proximal occlusion and 25 with distal occlusion. Following proximal occlusion relative to distal occlusion, FMD was larger (16.2 ± 1.2% vs. 7.3 ± 0.9%, p < 0.0001) and elongated (107.2 s vs. 67.8 s, p = 0.0001). Measurement of the test repeatability showed that differences between the repeated measures were greater on average when the measurements were done using the proximal method as compared to the distal method (2.4%; 95% CI 0.5–4.3; p = 0.013). CONCLUSION: These findings suggest that forearm compression holds statistical advantages over upper arm compression. Added to documented physiological and practical reasons, we propose that future studies should use forearm compression in the assessment of endothelial function

    Image-guided ToF depth upsampling: a survey

    Get PDF
    Recently, there has been remarkable growth of interest in the development and applications of time-of-flight (ToF) depth cameras. Despite the permanent improvement of their characteristics, the practical applicability of ToF cameras is still limited by low resolution and quality of depth measurements. This has motivated many researchers to combine ToF cameras with other sensors in order to enhance and upsample depth images. In this paper, we review the approaches that couple ToF depth images with high-resolution optical images. Other classes of upsampling methods are also briefly discussed. Finally, we provide an overview of performance evaluation tests presented in the related studies
    corecore