388 research outputs found

    Force-gradient-induced mechanical dissipation of quartz tuning fork force sensors used in atomic force microscopy

    Full text link
    We have studied the dynamics of quartz tuning fork resonators used in atomic force microscopy taking into account mechanical energy dissipation through the attachment of the tuning fork base. We find that the tuning fork resonator quality factor changes even for the case of a purely elastic sensor-sample interaction. This is due to the effective mechanical imbalance of the tuning fork prongs induced by the sensor-sample force gradient which in turn has an impact on the dissipation through the attachment of the resonator base. This effect may yield a measured dissipation signal that can be different to the one exclusively related to the dissipation between the sensor and the sample. We also find that there is a second order term in addition to the linear relationship between the sensor-sample force gradient and the resonance frequency shift of the tuning fork that is significant even for force gradients usually present in atomic force microscopy which are in the range of tens of N/m.Comment: 9 pages, 3 figures and supplemental informatio

    Purification of single-walled carbon nanotubes

    Get PDF
    We present a study of purification of single-walled carbon nanotubes (SWCNTs) using different oxidation temperatures and chemical treatments. We have developed a simple two annealing-steps procedure resulting in high nanotube purity with minimal sample loss. The process involves annealing the SWCNTs at 300˚C for 2 h with subsequent reflux in 6 M HCl at 130˚C, followed by further annealing at 350˚C for 1 h with reflux in 6 M HCl at 130˚C. The process results in effective removal of carbon impurities and metal particles which are associated with SWCNTs production. The process is less time-consuming (complete in 4.5 h) than conventional acid purification methods which require over 5 h, and less destructive than conventional methods with a yield of 26%. SWCNT purity was assessed using Raman spectroscopy, thermogravimetry and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy

    Anodization of nanoporous alumina on impurity-induced hemisphere curved surface of aluminum at room temperature

    Get PDF
    Nanoporous alumina which was produced by a conventional direct current anodization [DCA] process at low temperatures has received much attention in various applications such as nanomaterial synthesis, sensors, and photonics. In this article, we employed a newly developed hybrid pulse anodization [HPA] method to fabricate the nanoporous alumina on a flat and curved surface of an aluminum [Al] foil at room temperature [RT]. We fabricate the nanopores to grow on a hemisphere curved surface and characterize their behavior along the normal vectors of the hemisphere curve. In a conventional DCA approach, the structures of branched nanopores were grown on a photolithography-and-etched low-curvature curved surface with large interpore distances. However, a high-curvature hemisphere curved surface can be obtained by the HPA technique. Such a curved surface by HPA is intrinsically induced by the high-resistivity impurities in the aluminum foil and leads to branching and bending of nanopore growth via the electric field mechanism rather than the interpore distance in conventional approaches. It is noted that by the HPA technique, the Joule heat during the RT process has been significantly suppressed globally on the material, and nanopores have been grown along the normal vectors of a hemisphere curve. The curvature is much larger than that in other literatures due to different fabrication methods. In theory, the number of nanopores on the hemisphere surface is two times of the conventional flat plane, which is potentially useful for photocatalyst or other applications

    Grafting of 4-(2,4,6-Trimethylphenoxy)benzoyl onto Single-Walled Carbon Nanotubes in Poly(phosphoric acid) via Amide Function

    Get PDF
    Single-walled carbon nanotubes (SWCNTs), which were commercial grade containing 60–70 wt% impurity, were treated in a mild poly(phosphoric acid) (PPA). The purity of PPA treated SWCNTs was greatly improved with or without little damage to SWCNTs framework and stable crystalline carbon particles. An amide model compound, 4-(2,4,6-trimethylphenoxy)benzamide (TMPBA), was reacted with SWCNTs in PPA with additional phosphorous pentoxide as “direct” Friedel–Crafts acylation reaction to afford TMPBA functionalized SWCNTs. All evidences obtained from Fourier-transform infrared spectroscopy, Raman spectroscopy, thermogravimetric analysis, scanning electron microcopy, and transmission electron microscopy strongly supported that the functionalization of SWCNTs with benzamide was indeed feasible

    Ion mobility spectrometry-mass spectrometry (IMS-MS) of small molecules: separating and assigning structures to ions

    Get PDF
    The phenomenon of ion mobility (IM), the movement/transport of charged particles under the influence of an electric field, was first observed in the early 20th Century and harnessed later in ion mobility spectrometry (IMS). There have been rapid advances in instrumental design, experimental methods, and theory together with contributions from computational chemistry and gas-phase ion chemistry, which have diversified the range of potential applications of contemporary IMS techniques. Whilst IMS-mass spectrometry (IMS-MS) has recently been recognized for having significant research/applied industrial potential and encompasses multi-/cross-disciplinary areas of science, the applications and impact from decades of research are only now beginning to be utilized for "small molecule" species. This review focuses on the application of IMS-MS to "small molecule" species typically used in drug discovery (100-500 Da) including an assessment of the limitations and possibilities of the technique. Potential future developments in instrumental design, experimental methods, and applications are addressed. The typical application of IMS-MS in relation to small molecules has been to separate species in fairly uniform molecular classes such as mixture analysis, including metabolites. Separation of similar species has historically been challenging using IMS as the resolving power, R, has been low (3-100) and the differences in collision cross-sections that could be measured have been relatively small, so instrument and method development has often focused on increasing resolving power. However, IMS-MS has a range of other potential applications that are examined in this review where it displays unique advantages, including: determination of small molecule structure from drift time, "small molecule" separation in achiral and chiral mixtures, improvement in selectivity, identification of carbohydrate isomers, metabonomics, and for understanding the size and shape of small molecules. This review provides a broad but selective overview of current literature, concentrating on IMS-MS, not solely IMS, and small molecule applications. © 2012 Wiley Periodicals, Inc
    corecore