20 research outputs found
Production of highly-polarized positrons using polarized electrons at MeV energies
The Polarized Electrons for Polarized Positrons experiment at the injector of
the Continuous Electron Beam Accelerator Facility has demonstrated for the
first time the efficient transfer of polarization from electrons to positrons
produced by the polarized bremsstrahlung radiation induced by a polarized
electron beam in a high- target. Positron polarization up to 82\% have been
measured for an initial electron beam momentum of 8.19~MeV/, limited only by
the electron beam polarization. This technique extends polarized positron
capabilities from GeV to MeV electron beams, and opens access to polarized
positron beam physics to a wide community.Comment: 5 pages, 4 figure
Beam dynamics driven design of powerful energy recovery linac for experiments
Powerful ERL for experiments (PERLE) is a novel energy recovery linac (ERL) test facility [1], designed to validate choices for a 50 GeV ERL foreseen in the design of the Large Hadron Electron Collider and the Future Circular Collider and to host dedicated nuclear and particle physics experiments. Its main goal is to demonstrate the high current, continuous wave, multipass operation with superconducting cavities at 802 MHz. With very high beam power (10 MW), PERLE offers an opportunity for controllable study of every beam dynamic effect of interest in the next generation of ERLs and becomes a “stepping stone” between the present state-of-the-art 1 MW ERLs and the future 100 MW scale applications
The Large Hadron-Electron Collider at the HL-LHC
The Large Hadron-Electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy-recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High-Luminosity Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent electron-proton and proton-proton operations. This report represents an update to the LHeC's conceptual design report (CDR), published in 2012. It comprises new results on the parton structure of the proton and heavier nuclei, QCD dynamics, and electroweak and top-quark physics. It is shown how the LHeC will open a new chapter of nuclear particle physics by extending the accessible kinematic range of lepton-nucleus scattering by several orders of magnitude. Due to its enhanced luminosity and large energy and the cleanliness of the final hadronic states, the LHeC has a strong Higgs physics programme and its own discovery potential for new physics. Building on the 2012 CDR, this report contains a detailed updated design for the energy-recovery electron linac (ERL), including a new lattice, magnet and superconducting radio-frequency technology, and further components. Challenges of energy recovery are described, and the lower-energy, high-current, three-turn ERL facility, PERLE at Orsay, is presented, which uses the LHeC characteristics serving as a development facility for the design and operation of the LHeC. An updated detector design is presented corresponding to the acceptance, resolution, and calibration goals that arise from the Higgs and parton-density-function physics programmes. This paper also presents novel results for the Future Circular Collider in electron-hadron (FCC-eh) mode, which utilises the same ERL technology to further extend the reach of DIS to even higher centre-of-mass energies.Peer reviewe
The Large Hadron–Electron Collider at the HL-LHC
The Large Hadron–Electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy-recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High-Luminosity Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent electron–proton and proton–proton operations. This report represents an update to the LHeC’s conceptual design report (CDR), published in 2012. It comprises new results on the parton structure of the proton and heavier nuclei, QCD dynamics, and electroweak and top-quark physics. It is shown how the LHeC will open a new chapter of nuclear particle physics by extending the accessible kinematic range of lepton–nucleus scattering by several orders of magnitude. Due to its enhanced luminosity and large energy and the cleanliness of the final hadronic states, the LHeC has a strong Higgs physics programme and its own discovery potential for new physics. Building on the 2012 CDR, this report contains a detailed updated design for the energy-recovery electron linac (ERL), including a new lattice, magnet and superconducting radio-frequency technology, and further components. Challenges of energy recovery are described, and the lower-energy, high-current, three-turn ERL facility, PERLE at Orsay, is presented, which uses the LHeC characteristics serving as a development facility for the design and operation of the LHeC. An updated detector design is presented corresponding to the acceptance, resolution, and calibration goals that arise from the Higgs and parton-density-function physics programmes. This paper also presents novel results for the Future Circular Collider in electron–hadron (FCC-eh) mode, which utilises the same ERL technology to further extend the reach of DIS to even higher centre-of-mass energies
THE IMPACT OF BEAM LOADING TRANSIENTS ON THE RF SYSTEM AND BEAM BREAKUP INSTABILITIES IN ENERGY RECOVERY LINACS
In multi-turn Energy Recovery Linacs (ERLs), the filling pattern describes the order that which bunches are injected into the ERL ring. The filling patterns and recombination schemes together can create various beam loading patterns/transients, which can have a big impact on the RF system, namely the cavity fundamental mode voltage, required RF power, and beam breakup instability. In this work, we demonstrate one can lower the cavity voltage fluctuation and rf power consumption by carefully choosing the right transient by using an analytical model and simulation
Recommended from our members
Transverse Beam Emittance Measurements of a 16 MeV Linac at the Idaho Accelerator Center
A beam emittance measurement of the 16 MeV S-band High Repetition Rate Linac (HRRL) was performed at Idaho State University's Idaho Accelerator Center (IAC). The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1 kHz. Measurements of the HRRL transverse beam emittance are underway that will be used to optimize the production of positrons using HRRL's intense electron beam on a tungsten converter. In this paper, we describe a beam imaging system using on an OTR screen and a digital CCD camera, a MATLAB tool to extract beamsize and emittance, detailed measurement procedures, and the measured transverse emittances for an arbitrary beam energy of 15 MeV