2,601 research outputs found

    Dual function filtration and catalytic breakdown of organic pollutants in wastewater using ozonation with titania and alumina membranes

    Get PDF
    Water recycling via treatment from industrial and/or municipal waste sources is one of the key strategies for resolving water shortages worldwide. Polymer membranes are effective at improving the water quality essential for recycling, but depend on regular cleaning and replacement. Pure ceramic membranes can reduce the cleaning need and last significantly longer in the same applications while possessing the possibility of operating in more aggressive environments not suitable for polymers. In the current work, filtration using a tubular ceramic membrane (�-Al2O3 or TiO2) was combined with ozonation to remove organic compounds present in a secondary effluent to enhance key quality features of the water (colour and total organic carbon, TOC) for its potential reuse. ‘Bare’ commercial �-Al2O3 filters (pore size ∼0.58 �m) were tested as a microfiltration membrane and compared with the more advanced catalytically active TiO2 layer that was formed by the sol–gel method. The presence of anatase with a 4 nm pore size at the membrane surface was confirmed by X-ray diffraction (XRD) and N2 adsorption. Filtration of the effluent over a 2 h period led to a reduction in flux to 45% and 60% of the initial values for the �-alumina and TiO2 membrane, respectively. However, a brief dose (2 min) of ozone at the start of the run resulted in reductions to only 70% of the initial flux for both membranes. It is likely that the oxide’s functional property facilitated the formation of hydroxyl (OH•) or other radicals on the membrane surface from ozone decomposition which targeted the breakdown of organic foulants thus inhibiting their deposition. Interestingly, the porous structure therefore acted in a synergistic, dual function mode to physically separate the particulates while also catalytically breaking down organic matter. The system also greatly improved the efficiency of membrane filtration for the reduction of colour, A254 (organics absorption at the wavelength of 254 nm) and TOC. The best performance came from combined ozonation (2 min ozonation time with an estimated applied ozone dose of 8 mg L−1) with the TiO2 membrane, which was able to reduce colour by 88%, A254 by 75% and TOC by 43%. It is clearly evident that a synergistic effect occurs with the process combination of ozonation and ceramic membrane filtration demonstrating the practical benefit of combining ceramic membrane filtration with conventional water ozonation

    Grb2 monomer-dimer equilibrium determines normal versus oncogenic function

    Get PDF
    The adaptor protein growth factor receptor-bound protein 2 (Grb2) is ubiquitously expressed in eukaryotic cells and involved in a multitude of intracellular protein interactions. Grb2 plays a pivotal role in tyrosine kinase-mediated signal transduction including linking receptor tyrosine kinases to the Ras/mitogen-activated protein (MAP) kinase pathway, which is implicated in oncogenic outcome. Grb2 exists in a constitutive equilibrium between monomeric and dimeric states. Here we show that only monomeric Grb2 is capable of binding to SOS and upregulating MAP kinase signalling and that the dimeric state is inhibitory to this process. Phosphorylation of tyrosine 160 (Y160) on Grb2, or binding of a tyrosylphosphate-containing ligand to the SH2 domain of Grb2, results in dimer dissociation. Phosphorylation of Y160 on Grb2 is readily detectable in the malignant forms of human prostate, colon and breast cancers. The self-association/dissociation of Grb2 represents a switch that regulates MAP kinase activity and hence controls cancer progression

    A Critical Review of Biomarkers Used for Monitoring Human Exposure to Lead: Advantages, Limitations, and Future Needs

    Get PDF
    Lead concentration in whole blood (BPb) is the primary biomarker used to monitor exposure to this metallic element. The U.S. Centers for Disease Control and Prevention and the World Health Organization define a BPb of 10 μg/dL (0.48 μmol/L) as the threshold of concern in young children. However, recent studies have reported the possibility of adverse health effects, including intellectual impairment in young children, at BPb levels < 10 μg/dL, suggesting that there is no safe level of exposure. It appears impossible to differentiate between low-level chronic Pb exposure and a high-level short Pb exposure based on a single BPb measurement; therefore, serial BPb measurements offer a better estimation of possible health outcomes. The difficulty in assessing the exact nature of Pb exposure is dependent not so much on problems with current analytical methodologies, but rather on the complex toxicokinetics of Pb within various body compartments (i.e., cycling of Pb between bone, blood, and soft tissues). If we are to differentiate more effectively between Pb stored in the body for years and Pb from recent exposure, information on other biomarkers of exposure may be needed. None of the current biomarkers of internal Pb dose have yet been accepted by the scientific community as a reliable substitute for a BPb measurement. This review focuses on the limitations of biomarkers of Pb exposure and the need to improve the accuracy of their measurement. We present here only the traditional analytical protocols in current use, and we attempt to assess the influence of confounding variables on BPb levels. Finally, we discuss the interpretation of BPb data with respect to both external and endogenous Pb exposure, past or recent exposure, as well as the significance of Pb determinations in human specimens including hair, nails, saliva, bone, blood (plasma, whole blood), urine, feces, and exfoliated teeth

    Observation of electron transfer mediated decay in aqueous solution

    Get PDF
    Photoionization is at the heart of X ray photoelectron spectroscopy XPS , which gives access to important information on a sample s local chemical environment. Local and non local electronic decay after photoionization in which the refilling of core holes results in electron emission from either the initially ionized species or a neighbour, respectively have been well studied. However, electron transfer mediated decay ETMD , which involves the refilling of a core hole by an electron from a neighbouring species, has not yet been observed in condensed phase. Here we report the experimental observation of ETMD in an aqueous LiCl solution by detecting characteristic secondary low energy electrons using liquid microjet soft XPS. Experimental results are interpreted using molecular dynamics and high level ab initio calculations. We show that both solvent molecules and counterions participate in the ETMD processes, and different ion associations have distinctive spectral fingerprints. Furthermore, ETMD spectra are sensitive to coordination numbers, ion solvent distances and solvent arrangemen

    Precision measurement of the top quark mass from dilepton events at CDF II

    Get PDF
    We report a measurement of the top quark mass, M_t, in the dilepton decay channel of ttˉb+νbˉνˉt\bar{t}\to b\ell'^{+}\nu_{\ell'}\bar{b}\ell^{-}\bar{\nu}_{\ell} using an integrated luminosity of 1.0 fb^{-1} of p\bar{p} collisions collected with the CDF II detector. We apply a method that convolutes a leading-order matrix element with detector resolution functions to form event-by-event likelihoods; we have enhanced the leading-order description to describe the effects of initial-state radiation. The joint likelihood is the product of the likelihoods from 78 candidate events in this sample, which yields a measurement of M_{t} = 164.5 \pm 3.9(\textrm{stat.}) \pm 3.9(\textrm{syst.}) \mathrm{GeV}/c^2, the most precise measurement of M_t in the dilepton channel.Comment: 7 pages, 2 figures, version includes changes made prior to publication by journa

    Measurement of the Ratios of Branching Fractions B(Bs -> Ds pi pi pi) / B(Bd -> Dd pi pi pi) and B(Bs -> Ds pi) / B(Bd -> Dd pi)

    Get PDF
    Using 355 pb^-1 of data collected by the CDF II detector in \ppbar collisions at sqrt{s} = 1.96 TeV at the Fermilab Tevatron, we study the fully reconstructed hadronic decays B -> D pi and B -> D pi pi pi. We present the first measurement of the ratio of branching fractions B(Bs -> Ds pi pi pi) / B(Bd -> Dd pi pi pi) = 1.05 pm 0.10 (stat) pm 0.22 (syst). We also update our measurement of B(Bs -> Ds pi) / B(Bd -> Dd pi) to 1.13 pm 0.08 (stat) pm 0.23 (syst) improving the statistical uncertainty by more than a factor of two. We find B(Bs -> Ds pi) = [3.8 pm 0.3 (stat) pm 1.3 (syst)] \times 10^{-3} and B(Bs -> Ds pi pi pi) = [8.4 pm 0.8 (stat) pm 3.2 (syst)] \times 10^{-3}.Comment: 7 pages, 2 figure

    Cross Section Measurements of High-pTp_T Dilepton Final-State Processes Using a Global Fitting Method

    Get PDF
    We present a new method for studying high-pTp_T dilepton events (e±ee^{\pm}e^{\mp}, μ±μ\mu^{\pm}\mu^{\mp}, e±μe^{\pm}\mu^{\mp}) and simultaneously extracting the production cross sections of ppˉttˉp\bar{p} \to t\bar{t}, ppˉW+Wp\bar{p} \to W^+W^-, and p\bar{p} \to \ztt at a center-of-mass energy of s=1.96\sqrt{s} = 1.96 TeV. We perform a likelihood fit to the dilepton data in a parameter space defined by the missing transverse energy and the number of jets in the event. Our results, which use 360pb1360 {\rm pb^{-1}} of data recorded with the CDF II detector at the Fermilab Tevatron Collider, are σ(ttˉ)=8.52.2+2.7\sigma(t\bar{t}) = 8.5_{-2.2}^{+2.7} pb, σ(W+W)=16.34.4+5.2\sigma(W^+W^-) = 16.3^{+5.2}_{-4.4} pb, and \sigma(\ztt) =291^{+50}_{-46} pb.Comment: 20 pages, 2 figures, to be submitted to PRD-R

    Measurement of the Lambda_b Lifetime in Lambda_b --> J/psi Lambda0 in p-pbar Collisions at sqrt(s)=1.96 TeV

    Get PDF
    We report a measurement of the Lambda_b lifetime in the exclusive decay Lambda_b --> J/psi Lambda0 in p-pbar collisions at sqrt(s) = 1.96 TeV using an integrated luminosity of 1.0 fb^{-1} of data collected by the CDF II detector at the Fermilab Tevatron. Using fully reconstructed decays, we measure tau(Lambda_b) = 1.593 ^{+0.083}_{-0.078} (stat.) +- 0.033 (syst.) ps. This is the single most precise measurement of tau(Lambda_b) and is 3.2 sigma higher than the current world average.Comment: 7 Pages, 2 Figures, 1 Table. Submitted to Phys. Rev. Let

    Limits on Anomalous Triple Gauge Couplings in ppbar Collisions at sqrt{s}=1.96 TeV

    Get PDF
    We present a search for anomalous triple gauge couplings (ATGC) in WW and WZ boson production. The boson pairs are produced in ppbar collisions at sqrt{s}=1.96 TeV, and the data sample corresponds to 350 pb-1 of integrated luminosity collected with the CDF II detector at the Fermilab Tevatron. In this search one W decays to leptons, and the other boson (W or Z) decays hadronically. Combining with a previously published CDF measurement of Wgamma boson production yields ATGC limits of -0.18 < lambda < 0.17 and -0.46 < Delta kappa < 0.39 at the 95% confidence level, using a cut-off scale Lambda=1.5 TeV.Comment: 7 pages, 3 figures. Submitted to Phys. Rev.
    corecore