1,170 research outputs found

    Rapid flow-sorting to simultaneously resolve multiplex massively parallel sequencing products

    Get PDF
    Sample preparation for Roche/454, ABI/SOLiD and Life Technologies/Ion Torrent sequencing are based on amplification of library fragments on the surface of beads prior to sequencing. Commonly, libraries are barcoded and pooled, to maximise the sequence output of each sequence run. Here, we describe a novel approach for normalization of multiplex next generation sequencing libraries after emulsion PCR. Briefly, amplified libraries carrying unique barcodes are prepared by fluorescent tagging of complementary sequences and then resolved by high-speed flow cytometric sorting of labeled emulsion PCR beads. The protocol is simple and provides an even sequence distribution of multiplex libraries when sequencing the flow-sorted beads. Moreover, since many empty and mixed emulsion PCR beads are removed, the approach gives rise to a substantial increase in sequence quality and mean read length, as compared to that obtained by standard enrichment protocols

    What are we measuring? A critique of range of motion methods currently in use for Dupuytren's disease and recommendations for practice

    Get PDF
    Background: Range of motion is the most frequently reported measure used in practice to evaluate outcomes. A goniometer is the most reliable tool to assess range of motion yet, the lack of consistency in reporting prevents comparison between studies. The aim of this study is to identify how range of motion is currently assessed and reported in Dupuytren’s disease literature. Following analysis recommendations for practice will be made to enable consistency in future studies for comparability. This paper highlights the variation in range of motion reporting in Dupuytren’s disease. Methods: A Participants, Intervention, Comparison, Outcomes and Study design format was used for the search strategy and search terms. Surgery, needle fasciotomy or collagenase injection for primary or recurrent Dupuytren’s disease in adults were included if outcomes were monitored using range of motion to record change. A literature search was performed in May 2013 using subject heading and free-text terms to also capture electronic publications ahead of print. In total 638 publications were identified and following screening 90 articles met the inclusion criteria. Data was extracted and entered onto a spreadsheet for analysis. A thematic analysis was carried out to establish any duplication, resulting in the final range of motion measures identified. Results: Range of motion measurement lacked clarity, with goniometry reportedly used in only 43 of the 90 studies, 16 stated the use of a range of motion protocol. A total of 24 different descriptors were identified describing range of motion in the 90 studies. While some studies reported active range of motion, others reported passive or were unclear. Eight of the 24 categories were identified through thematic analysis as possibly describing the same measure, ‘lack of joint extension’ and accounted for the most frequently used. Conclusions: Published studies lacked clarity in reporting range of motion, preventing data comparison and meta-analysis. Percentage change lacks context and without access to raw data, does not allow direct comparison of baseline characteristics. A clear description of what is being measured within each study was required. It is recommended that range of motion measuring and reporting for Dupuytren’s disease requires consistency to address issues that fall into 3 main categories:- Definition of terms Protocol statement Outcome reportin

    Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice

    Get PDF
    This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes

    Steroid regulation: An overlooked aspect of tolerance and chronic rejection in kidney transplantation.

    Get PDF
    Steroid conversion (HSD11B1, HSD11B2, H6PD) and receptor genes (NR3C1, NR3C2) were examined in kidney-transplant recipients with "operational tolerance" and chronic rejection (CR), independently and within the context of 88 tolerance-associated genes. Associations with cellular types were explored. Peripheral whole-blood gene-expression levels (RT-qPCR-based) and cell counts were adjusted for immunosuppressant drug intake. Tolerant (n = 17), stable (n = 190) and CR patients (n = 37) were compared. Healthy controls (n = 14) were used as reference. The anti-inflammatory glucocorticoid receptor (NR3C1) and the cortisol-activating HSD11B1 and H6PD genes were up-regulated in CR and were lowest in tolerant patients. The pro-inflammatory mineralocorticoid gene (NR3C2) was downregulated in stable and CR patients. NR3C1 was associated with neutrophils and NR3C2 with T-cells. Steroid conversion and receptor genes, alone, enabled classification of tolerant patients and were major contributors to gene-expression signatures of both, tolerance and CR, alongside known tolerance-associated genes, revealing a key role of steroid regulation and response in kidney transplantation

    Strong interface-induced spin-orbit coupling in graphene on WS2

    Get PDF
    Interfacial interactions allow the electronic properties of graphene to be modified, as recently demonstrated by the appearance of satellite Dirac cones in the band structure of graphene on hexagonal boron nitride (hBN) substrates. Ongoing research strives to explore interfacial interactions in a broader class of materials in order to engineer targeted electronic properties. Here we show that at an interface with a tungsten disulfide (WS2) substrate, the strength of the spin-orbit interaction (SOI) in graphene is very strongly enhanced. The induced SOI leads to a pronounced low-temperature weak anti-localization (WAL) effect, from which we determine the spin-relaxation time. We find that spin-relaxation time in graphene is two-to-three orders of magnitude smaller on WS2 than on SiO2 or hBN, and that it is comparable to the intervalley scattering time. To interpret our findings we have performed first-principle electronic structure calculations, which both confirm that carriers in graphene-on-WS2 experience a strong SOI and allow us to extract a spin-dependent low-energy effective Hamiltonian. Our analysis further shows that the use of WS2 substrates opens a possible new route to access topological states of matter in graphene-based systems.Comment: Originally submitted version in compliance with editorial guidelines. Final version with expanded discussion of the relation between theory and experiments to be published in Nature Communication

    Quantifying Missing Heritability at Known GWAS Loci

    Get PDF
    Recent work has shown that much of the missing heritability of complex traits can be resolved by estimates of heritability explained by all genotyped SNPs. However, it is currently unknown how much heritability is missing due to poor tagging or additional causal variants at known GWAS loci. Here, we use variance components to quantify the heritability explained by all SNPs at known GWAS loci in nine diseases from WTCCC1 and WTCCC2. After accounting for expectation, we observed all SNPs at known GWAS loci to explain 1.29 X more heritability than GWAS-associated SNPs on average (P = 3.3 X 10[superscript -5]). For some diseases, this increase was individually significant:2.07 X for Multiple Sclerosis (MS) (P = 6.5 X 10 [superscript -9]) and for Crohn's Disease (CD) (P = 1.3 X 10[superscript -3]); all analyses of autoimmune diseases excluded the well-studied MHC region. Additionally, we found that GWAS loci from other related traits also explained significant heritability. The union of all autoimmune disease loci explained 7.15 X more MS heritability than known MS SNPs (P 20,000 Rheumatoid Arthritis (RA) samples typed on ImmunoChip, with 2.37 X more heritability from all SNPs at GWAS loci (P = 2.3 X 10[superscript -6]) and more heritability from all autoimmune disease loci (P < 1 X 10[superscript -16]) compared to known RA SNPs (including those identified in this cohort). Our methods adjust for LD between SNPs, which can bias standard estimates of heritability from SNPs even if all causal variants are typed. By comparing adjusted estimates, we hypothesize that the genome-wide distribution of causal variants is enriched for low-frequency alleles, but that causal variants at known GWAS loci are skewed towards common alleles. These findings have important ramifications for fine-mapping study design and our understanding of complex disease architecture.National Institutes of Health (U.S.) (Grant R03HG006731)National Institutes of Health (U.S.) (Fellowship F32GM106584

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
    corecore