42 research outputs found

    Differences in the yield of the implantable loop recorder between secondary and tertiary centers

    Get PDF
    Background: The implantable loop recorder (ILR) is a useful tool for diagnosis of syncope or palpitations. Its easy use and safety have extended its use to secondary hospitals (those without an Electrophysiology Lab). The aim of the study was to compare results between secondary and tertiary hospitals. Methods: National prospective and multicenter registry of patients with an ILR inserted for clinical reasons. Data were collected in an online database. The follow-up ended when the first diagnostic clinical event occurred, or 1 year after implantation. Data were analyzed according to the center of reference; hospitals with Electrophysiology Lab were considered Tertiary Hospi­tals, while those hospitals without a lab were considered Secondary Hospitals. Results: Seven hundred and forty-three patients (413 [55.6%] men; 65 ± 16 year-old): 655 (88.2%) from Tertiary Centers (TC) and 88 (11.8%) from Secondary Centers (SC). No differences in clinical characteristics between both groups were found. The electrophysi­ologic study and the tilt table test were conducted more frequently in Tertiary Centers. Fol­low-up was conducted for 680 (91.5%) patients: 91% in TC and 94% in SC. There was a higher rate of final diagnosis among SC patients (55.4% vs. 30.8%; p < 0.001). Tertiary Hospital patients showed a trend towards a higher rate of neurally mediated events (20% vs. 4%), while bradyarrhythmias were more frequent in SC (74% vs. 60%; p = 0.055). The rate of deaths and adverse events was similar in both populations. Conclusions: Patients with an ILR in SC and TC have differences in terms of the use of complementary tests, but not in clinical characteristics. There was a higher rate of diagnosis in Secondary Hospital patients.

    Left atrial geometry and outcome of atrial fibrillation ablation: results from the multicentre LAGO-AF study

    Get PDF
    Aims: Left atrial (LA) remodelling is a key determinant of atrial fibrillation (AF) ablation outcome. Optimal methods to assess this process are scarce. LA sphericity is a shape-based parameter shown to be independently associated to procedural success. In a multicentre study, we aimed to test the feasibility of assessing LA sphericity and evaluate its capability to predict procedural outcomes. Methods and results: This study included consecutive patients undergoing first AF ablation during 2013. A 3D model of the LA chamber, excluding pulmonary veins and LA appendage, was used to quantify LA volume (LAV) and LA sphericity (≥82.1% was considered spherical LA). In total, 243 patients were included across 9 centres (71% men, aged 56 ± 10 years, 44% with hypertension and 76% CHA2DS2-VASc ≤ 1). Most patients had paroxysmal AF (66%) and underwent radiofrequency ablation (60%). Mean LA diameter (LAD), LAV, and LA sphericity were 42 ± 6 mm, 100 ± 33 mL, and 82.6 ± 3.5%, respectively. Adjusted Cox models identified paroxysmal AF [hazard ratio (HR 0.54, P = 0.032)] and LA sphericity (HR 1.87, P = 0.035) as independent predictors for AF recurrence. A combined clinical-imaging score [Left Atrial Geometry and Outcome (LAGO)] including five items (AF phenotype, structural heart disease, CHA2DS2-VASc ≤ 1, LAD, and LA sphericity) classified patients at low (≤2 points) and high risk (≥3 points) of procedural failure (35% vs. 82% recurrence at 3-year follow-up, respectively; HR 3.10, P < 0.001). Conclusion: In this multicentre, real-life cohort, LA sphericity and AF phenotype were the strongest predictors of AF ablation outcome after adjustment for covariates. The LAGO score was easy to implement, identified high risk of procedural failure, and could help select optimal candidates. Clinical Trial Registration Information: NCT02373982 (http://clinicaltrials.gov/ct2/show/NCT02373982)

    Cardiac magnetic resonance outperforms echocardiography to predict subsequent implantable cardioverter defibrillator therapies in ST-segment elevation myocardial infarction patients

    Get PDF
    Altres ajuts: Conselleria de Educación-Generalitat Valenciana (PROMETEO/2021/008); Sociedad Española de Cardiología (Grant SEC/FEC-INVCLI 21/024)Implantable cardioverter defibrillators (ICD) are effective as a primary prevention measure of ventricular tachyarrhythmias in patients with ST-segment elevation myocardial infarction (STEMI) and depressed left ventricular ejection fraction (LVEF). The implications of using cardiac magnetic resonance (CMR) instead of echocardiography (Echo) to assess LVEF prior to the indication of ICD in this setting are unknown. We evaluated 52 STEMI patients (56.6 ± 11 years, 88.5% male) treated with ICD in primary prevention who underwent echocardiography and CMR prior to ICD implantation. ICD implantation was indicated based on the presence of heart failure and depressed LVEF (≤ 35%) by echocardiography, CMR, or both. Prediction of ICD therapies (ICD-T) during follow-up by echocardiography and CMR before ICD implantation was assessed. Compared to echocardiography, LVEF was lower by cardiac CMR (30.2 ± 9% vs. 37.4 ± 7.6%, p < 0.001). LVEF ≤ 35% was detected in 24 patients (46.2%) by Echo and in 42 (80.7%) by CMR. During a mean follow-up of 6.1 ± 4.2 years, 10 patients received appropriate ICD-T (3.16 ICD-T per 100 person-years): 5 direct shocks to treat very fast ventricular tachycardia or ventricular fibrillation, 3 effective antitachycardia pacing (ATP) for treatment of ventricular tachycardia, and 2 ineffective ATP followed by shock to treat ventricular tachycardia. Echo-LVEF ≤ 35% correctly predicted ICD-T in 4/10 (40%) patients and CMR-LVEF ≤ 35% in 10/10 (100%) patients. CMR-LVEF improved on Echo-LVEF for predicting ICD-T (area under the curve: 0.76 vs. 0.48, p = 0.04). In STEMI patients treated with ICD, assessment of LVEF by CMR outperforms Echo-LVEF to predict the subsequent use of appropriate ICD therapies

    Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications

    Get PDF
    BACKGROUND Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. OBJECTIVES To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. DESIGN This was a prospective international 1-week observational study using the ‘Assess Respiratory Risk in Surgical Patients in Catalonia risk score’ (ARISCAT score) for PPC for risk stratification. PATIENTS AND SETTING Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. MAIN OUTCOME MEASURES The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. RESULTS A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (VT) size was 500 ml, or 7 to 9 ml kg1 predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P < 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P < 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. CONCLUSION The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high VT and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome

    Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications: LAS VEGAS - An observational study in 29 countries

    Get PDF
    BACKGROUND Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. OBJECTIVES To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. DESIGN This was a prospective international 1-week observational study using the ‘Assess Respiratory Risk in Surgical Patients in Catalonia risk score’ (ARISCAT score) for PPC for risk stratification. PATIENTS AND SETTING Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. MAIN OUTCOME MEASURES The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. RESULTS A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (V T) size was 500 ml, or 7 to 9 ml kg−1 predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P ˂ 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P ˂ 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. CONCLUSION The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high V T and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome.</p

    Sex difference and intra-operative tidal volume: Insights from the LAS VEGAS study

    Get PDF
    BACKGROUND: One key element of lung-protective ventilation is the use of a low tidal volume (VT). A sex difference in use of low tidal volume ventilation (LTVV) has been described in critically ill ICU patients.OBJECTIVES: The aim of this study was to determine whether a sex difference in use of LTVV also exists in operating room patients, and if present what factors drive this difference.DESIGN, PATIENTS AND SETTING: This is a posthoc analysis of LAS VEGAS, a 1-week worldwide observational study in adults requiring intra-operative ventilation during general anaesthesia for surgery in 146 hospitals in 29 countries.MAIN OUTCOME MEASURES: Women and men were compared with respect to use of LTVV, defined as VT of 8 ml kg-1 or less predicted bodyweight (PBW). A VT was deemed 'default' if the set VT was a round number. A mediation analysis assessed which factors may explain the sex difference in use of LTVV during intra-operative ventilation.RESULTS: This analysis includes 9864 patients, of whom 5425 (55%) were women. A default VT was often set, both in women and men; mode VT was 500 ml. Median [IQR] VT was higher in women than in men (8.6 [7.7 to 9.6] vs. 7.6 [6.8 to 8.4] ml kg-1 PBW, P &lt; 0.001). Compared with men, women were twice as likely not to receive LTVV [68.8 vs. 36.0%; relative risk ratio 2.1 (95% CI 1.9 to 2.1), P &lt; 0.001]. In the mediation analysis, patients' height and actual body weight (ABW) explained 81 and 18% of the sex difference in use of LTVV, respectively; it was not explained by the use of a default VT.CONCLUSION: In this worldwide cohort of patients receiving intra-operative ventilation during general anaesthesia for surgery, women received a higher VT than men during intra-operative ventilation. The risk for a female not to receive LTVV during surgery was double that of males. Height and ABW were the two mediators of the sex difference in use of LTVV.TRIAL REGISTRATION: The study was registered at Clinicaltrials.gov, NCT01601223

    Evolución de los pacientes con complicaciones locales en la bolsa del generador de un dispositivo implantable

    No full text
    Objetivo: Las recomendaciones para la extracción completa de la bolsa de dispositivos implantables por problemas locales han cambiado. Analizamos la evolución entre 2002 y 2010 de los pacientes que requirieron una intervención por una complicación local en nuestro centro. Métodos: Ochenta y tres pacientes tuvieron un problema local de la bolsa que se clasificó según integridad de la piel: 1. Íntegra y 2. Abierta, y el tipo de intervención realizada: 1. Conservadora, 2. Extracción parcial y 3. Extracción completa. El objetivo primario fue la necesidad de reintervención posterior y la de extracción total durante el seguimiento. Resultados: El grupo de pacientes con extracción completa presentó una menor tasa de reintervención durante el seguimiento medio de 1,000 días comparado con los otros 2 grupos (6.7 vs. 57.7 y 43.8%, p < 0.01). La extracción parcial y la actitud conservadora mostraron una evolución parecida con una tasa de extracción completa final del 25% y del 37.5%. Se observó una incidencia de endocarditis del 8.4%; todos con antecedente de extracción parcial o actitud conservadora. Conclusiones: Las complicaciones de la bolsa, independientemente de la integridad de la piel, tratadas conservadoramente o con extracción parcial se asocian a alta tasa de reintervenciones, necesidad de extracción completa y evolución a endocarditis

    Algorithm-based reduction of inappropriate defibrillator shock: Results of the Inappropriate Shock Reduction wIth PARAD+ Rhythm DiScrimination-Implantable Cardioverter Defibrillator Study.

    No full text
    BACKGROUND: Inappropriate shocks (IS) continue to have a major negative impact on patients implanted with defibrillators. OBJECTIVE: The purpose of this study was to assess IS reduction with the PARAD+ discrimination algorithm in a general population implanted for primary or secondary prevention. METHODS: ISIS-ICD (Inappropriate Shock Reduction wIth PARAD+ Rhythm DiScrimination-Implantable Cardioverter Defibrillator) was a 2-year international, interventional study in patients implanted with a dual implantable cardioverter-defibrillator (ICD) or triple-chamber defibrillator (cardiac resynchronization therapy-defibrillator [CRT-D]) featuring PARAD+. IS (shocks not delivered for ventricular tachycardia or fibrillation) were independently adjudicated. The primary endpoint was percentage of IS-free patients at 24 months. Primary and worst-case analyses of annual incidence rates of patients with ≥1 IS, overall and per defibrillator type, were conducted. RESULTS: In total, 1013 patients (80.7% male; age 67.1 ± 11.4 years; 68%/30%/2% primary/secondary/other indication) were enrolled and followed for a median of 552 days (interquartile range 354; 725). Of 993 analyzed patients programmed with PARAD+, 14 had ≥1 IS, corresponding to a percentage free from IS of 98.1% (95% confidence interval [CI] 96.8%- 98.9%). Annual incidence rates (per 100 person-years) of patients with IS were 1.0 (95% CI 0.59-1.69) and 2.1 (95% CI 1.46-3.02) in the primary and worst-case analyses, respectively. In ICD patients, rates were 1.2 (95% CI 0.68-2.23) and 2.3 (95% CI 1.47-3.53), and in CRT-D patients 0.59 (95% CI 0.19-1.83) and 1.8 (95% CI 0.93-3.44) per 100 person-years. CONCLUSION: The annual rate of defibrillator patients with IS using the enhanced PARAD+ discrimination algorithm alone ranged from 1.0 to 2.1 per 100 person-years in a general population implanted for primary or secondary prevention
    corecore