186 research outputs found
A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
Purpose
Schemes with high doses per fraction and small number of fractions are commonly used in high-dose-rate brachytherapy (HDR-BT) for prostate cancer. Our aim was to analyze the differences between published clinical results and the predictions of radiobiological models for absorbed dose required in a single fraction monotherapy HDR-BT.
Material and methods
Published HDR-BT clinical results for low- and intermediate-risk patients with prostate cancer were revised. For 13 clinical studies with 16 fractionation schedules between 1 and 9 fractions, a dose-response relation in terms of the biochemical control probability (BC) was established using Monte Carlo-based statistical methods.
Results
We obtained a value of α/β = 22.8 Gy (15.1-60.2 Gy) (95% CI) much larger than the values in the range 1.5-3.0 Gy that are usually considered to compare the results of different fractionation schemes in prostate cancer radiotherapy using doses per fraction below 6 Gy. The doses in a single fraction producing BC = 90% and 95% were 22.3 Gy (21.5-24.2 Gy) and 24.3 Gy (23.0-27.9 Gy), respectively.
Conclusions
The α/β obtained in our analysis of 22.8 Gy for a range of dose per fraction between 6 and 20.5 Gy was much greater than the one currently estimated for prostate cancer using low doses per fraction. This high value of α/β explains reasonably well the data available in the region of high doses per fraction considered.Spanish Ministerio de Ciencia y Competitividad
FPA2015-67694-PEuropean Union (EU)Junta de Andalucía
FQM038
Anthelmintic activity of aminoalcohol and diamine derivatives against the gastrointestinal nematode Teladorsagia circumcincta
11 páginas, 5 figuras, 4 tablas.Gastrointestinal nematodes (GIN) infections are a serious problem in livestock production due to the great economic losses they cause. Their control is increasingly difficult because of the rapid development of drug resistance and the limited number of available drugs. Therefore, this study evaluated 18 aminoalcohol and 16 diamine derivatives against eggs, first and third stage larvae from a susceptible and a resistant isolate of Tela-dorsagia circumcincta collected from sheep. The effectiveness of the in vitro anthelmintic activity of the com-pounds was evaluated using three different procedures: Egg Hatch Test (EHT), Larval Mortality Test (LMT) and Larval Migration Inhibition Test (LMIT). Those compounds with activities higher than 90 % in the initial screening at 50 μM were selected to determine their half maximal effective concentration (EC50). In parallel, cytotoxicity assays were conducted on Caco2 and HepG2 cell lines to calculate Selectivity Indexes (SI) for each compound. The diamine 30 presented the best results in preventing egg hatching, displaying the lowest EC50 value (1.01 ±0.04 μM) of all compounds tested and the highest SI (21.21 vs. Caco-2 cells). For the LMIT, the diamine 34 showed the highest efficacy, with EC50 values of 2.67 ±0.08 and 3.02 ±0.09 μM on the susceptible and resistant isolate of the parasite, respectively.We are grateful to Dave Bartley, from Moredun Research Institute for providing the triple-resistant isolate of T. circumcincta. RE thank the RICET contract (E07D401988BR) EC Programs. Financial support came from MINECO: RETOS (AGL2016-79813-C2-1R/2R) and Junta de Castilla y León (JCyL) co-financed by FEDER, UE (LE020P17). EVG was funded by FPU16/03536; JV, VCGA and MAB are recipients of Junta de Castilla y Leon and European Social Found (ESF)’s Fellowships Scheme for Doctoral Training Programs. (JCYL-USAL35B, LE082-18, LE051-18, respectively) and MMV by the Spanish “Ramon y Cajal” Programme (Ministerio de Economía y Competitividad; RYC-2015-18368).Peer reviewe
Highlights from the Pierre Auger Observatory
The Pierre Auger Observatory is the world's largest cosmic ray observatory.
Our current exposure reaches nearly 40,000 km str and provides us with an
unprecedented quality data set. The performance and stability of the detectors
and their enhancements are described. Data analyses have led to a number of
major breakthroughs. Among these we discuss the energy spectrum and the
searches for large-scale anisotropies. We present analyses of our X
data and show how it can be interpreted in terms of mass composition. We also
describe some new analyses that extract mass sensitive parameters from the 100%
duty cycle SD data. A coherent interpretation of all these recent results opens
new directions. The consequences regarding the cosmic ray composition and the
properties of UHECR sources are briefly discussed.Comment: 9 pages, 12 figures, talk given at the 33rd International Cosmic Ray
Conference, Rio de Janeiro 201
The Pierre Auger Observatory III: Other Astrophysical Observations
Astrophysical observations of ultra-high-energy cosmic rays with the Pierre
Auger ObservatoryComment: Contributions to the 32nd International Cosmic Ray Conference,
Beijing, China, August 201
Measurement of the Depth of Maximum of Extensive Air Showers above 10^18 eV
We describe the measurement of the depth of maximum, Xmax, of the
longitudinal development of air showers induced by cosmic rays. Almost four
thousand events above 10^18 eV observed by the fluorescence detector of the
Pierre Auger Observatory in coincidence with at least one surface detector
station are selected for the analysis. The average shower maximum was found to
evolve with energy at a rate of (106 +35/-21) g/cm^2/decade below 10^(18.24 +/-
0.05) eV and (24 +/- 3) g/cm^2/decade above this energy. The measured
shower-to-shower fluctuations decrease from about 55 to 26 g/cm^2. The
interpretation of these results in terms of the cosmic ray mass composition is
briefly discussed.Comment: Accepted for publication by PR
Operations of and Future Plans for the Pierre Auger Observatory
Technical reports on operations and features of the Pierre Auger Observatory,
including ongoing and planned enhancements and the status of the future
northern hemisphere portion of the Observatory. Contributions to the 31st
International Cosmic Ray Conference, Lodz, Poland, July 2009.Comment: Contributions to the 31st ICRC, Lodz, Poland, July 200
The Use of Corticosteroids or Tocilizumab in COVID-19 Based on Inflammatory Markers
SEMI-COVID-19 Network.[Background] The inflammatory cascade is the main cause of death in COVID-19 patients. Corticosteroids (CS) and tocilizumab (TCZ) are available to treat this escalation but which patients to administer it remains undefined.[Objective] We aimed to evaluate the efficacy of immunosuppressive/anti-inflammatory therapy in COVID-19, based on the degree of inflammation.
.[Design] A retrospective cohort study with data on patients collected and followed up from March 1st, 2020, to May 1st, 2021, from the nationwide Spanish SEMI-COVID-19 Registry. Patients under treatment with CS vs. those under CS plus TCZ were compared. Effectiveness was explored in 3 risk categories (low, intermediate, high) based on lymphocyte count, C-reactive protein (CRP), lactate dehydrogenase (LDH), ferritin, and d-dimer values.[Patients] A total of 21,962 patients were included in the Registry by May 2021. Of these, 5940 met the inclusion criteria for the present study (5332 were treated with CS and 608 with CS plus TCZ).[Main Measures] The primary outcome of the study was in-hospital mortality. Secondary outcomes were the composite variable of in-hospital mortality, requirement for high-flow nasal cannula (HFNC), non-invasive mechanical ventilation (NIMV), invasive mechanical ventilation (IMV), or intensive care unit (ICU) admission.[Key Results] A total of 5940 met the inclusion criteria for the present study (5332 were treated with CS and 608 with CS plus TCZ). No significant differences were observed in either the low/intermediate-risk category (1.5% vs. 7.4%, p=0.175) or the high-risk category (23.1% vs. 20%, p=0.223) after propensity score matching. A statistically significant lower mortality was observed in the very high–risk category (31.9% vs. 23.9%, p=0.049).[Conclusions] The prescription of CS alone or in combination with TCZ should be based on the degrees of inflammation and reserve the CS plus TCZ combination for patients at high and especially very high risk.Peer reviewe
The exposure of the hybrid detector of the Pierre Auger Observatory
The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays.
It consists of a surface array to measure secondary particles at ground level
and a fluorescence detector to measure the development of air showers in the
atmosphere above the array. The "hybrid" detection mode combines the
information from the two subsystems. We describe the determination of the
hybrid exposure for events observed by the fluorescence telescopes in
coincidence with at least one water-Cherenkov detector of the surface array. A
detailed knowledge of the time dependence of the detection operations is
crucial for an accurate evaluation of the exposure. We discuss the relevance of
monitoring data collected during operations, such as the status of the
fluorescence detector, background light and atmospheric conditions, that are
used in both simulation and reconstruction.Comment: Paper accepted by Astroparticle Physic
- …