23 research outputs found

    Improved time-resolved measurements of inorganic ions in particulate matter by PILS-IC integrated with a sample pre-concentration system

    Get PDF
    A particle-into-liquid sampler coupled with ion chromatograph (PILS-IC) for the on-line measurement of inorganic ions has been modified by the insertion of two ion-exchange pre-concentration cartridges that enrich the sample during the period of the IC analysis. The limits of detection of the modified instrument were 10-15 times lower and the time coverage 24 times higher (from 2 to 48 min per hour) than those of the original PILS-IC setup. The instrumental performance in terms of recovery and break-through volume from the cartridges was satisfactory. The modified PILS-IC was operated in comparison with a diffusion denuder line and with a high-resolution time-of-flight aerosol mass spectrometer (HR-TOF-AMS) during a short intensive measurement period organized in the framework of the European Monitoring and Evaluation Programme (EMEP), a co-operative program for monitoring and evaluation of the long-range transmission of the air pollutants in Europe. The instrument showed a quantitative response in agreement with the results of the diffusion lines, and an ability to trace fine concentration variations not so different from the performance of the much more complex HR-TOF-AMS. From the time patterns of the ion concentrations measured by the modified PILS-IC, it was possible to obtain useful information about the variations in the air quality and in the strength of the particulate matter sourc

    PRISMA - a magnetic spectrometer for heavy ions at LNL

    Get PDF
    Abstract The heavy-ion magnetic spectrometer PRISMA was recently installed at Laboratori Naz. di Legnaro, in order to exploit the heavy-ion beams of the XTU Tandem-ALPI-PIAVE accelerator complex, with masses up to A≃200 at energies ≃5-10 MeV MeV A

    Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system

    Get PDF
    Background: To assess the accuracy of fractionated stereotactic radiotherapy (FSRT) using a stereotactic mask fixation system. Patients and Methods: Sixteen patients treated with FSRT were involved in the study. A commercial stereotactic mask fixation system (BrainLAB AG) was used for patient immobilization. Serial CT scans obtained before and during FSRT were used to assess the accuracy of patient immobilization by comparing the isocenter position. Daily portal imaging were acquired to establish day to day patient position variation. Displacement errors along the different directions were calculated as combination of systematic and random errors. Results: The mean isocenter displacements based on localization and verification CT imaging were 0.1 mm (SD 0.3 mm) in the lateral direction, 0.1 mm (SD 0.4 mm) in the anteroposterior, and 0.3 mm (SD 0.4 mm) in craniocaudal direction. The mean 3D displacement was 0.5 mm (SD 0.4 mm), being maximum 1.4 mm. No significant differences were found during the treatment (P = 0.4). The overall isocenter displacement as calculated by 456 anterior and lateral portal images were 0.3 mm (SD 0.9 mm) in the mediolateral direction, -0.2 mm (SD 1 mm) in the anteroposterior direction, and 0.2 mm (SD 1.1 mm) in the craniocaudal direction. The largest displacement of 2.7 mm was seen in the cranio-caudal direction, with 95% of displacements < 2 mm in any direction. Conclusions: The results indicate that the setup error of the presented mask system evaluated by CT verification scans and portal imaging are minimal. Reproducibility of the isocenter position is in the best range of positioning reproducibility reported for other stereotactic systems

    Plant–environment interactions through a functional traits perspective: a review of Italian studies

    Get PDF
    Italy is among the European countries with the greatest plant diversity due to both a great environmental heterogeneity and a long history of man–environment interactions. Trait-based approaches to ecological studies have developed greatly over recent decades worldwide, although several issues concerning the relationships between plant functional traits and the environment still lack sufficient empirical evaluation. To draw insights on the association between plant functional traits and direct and indirect human and natural pressures on the environmental drivers, this article summarizes the existing knowledge on this topic by reviewing the results of studies performed in Italy adopting a functional trait approach on vascular plants, bryophytes and lichens. Although we recorded trait measurements for 1418 taxa, our review highlighted some major gaps in plant traits knowledge: Mediterranean ecosystems are poorly represented; traits related to belowground organs are still overlooked; traits measurements for bryophytes and lichens are lacking. Finally, intraspecific variation has been little studied at community level so far. We conclude by highlighting the need for approaches evaluating trait–environment relationship at large spatial and temporal scales and the need of a more effective contribution to online databases to tie more firmly Italian researchers to international scientific networks on plant traits

    Global Kalman filter approaches to estimate absolute angles of lower limb segments

    Get PDF
    [Background] In this paper we propose the use of global Kalman filters (KFs) to estimate absolute angles of lower limb segments. Standard approaches adopt KFs to improve the performance of inertial sensors based on individual link configurations. In consequence, for a multi-body system like a lower limb exoskeleton, the inertial measurements of one link (e.g., the shank) are not taken into account in other link angle estimations (e.g., foot). Global KF approaches, on the other hand, correlate the collective contribution of all signals from lower limb segments observed in the state-space model through the filtering process. We present a novel global KF (matricial global KF) relying only on inertial sensor data, and validate both this KF and a previously presented global KF (Markov Jump Linear Systems, MJLS-based KF), which fuses data from inertial sensors and encoders from an exoskeleton. We furthermore compare both methods to the commonly used local KF.[Results] The results indicate that the global KFs performed significantly better than the local KF, with an average root mean square error (RMSE) of respectively 0.942° for the MJLS-based KF, 1.167° for the matrical global KF, and 1.202° for the local KFs. Including the data from the exoskeleton encoders also resulted in a significant increase in performance.[Conclusion] The results indicate that the current practice of using KFs based on local models is suboptimal. Both the presented KF based on inertial sensor data, as well our previously presented global approach fusing inertial sensor data with data from exoskeleton encoders, were superior to local KFs. We therefore recommend to use global KFs for gait analysis and exoskeleton control.This work was supported by Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), under Grant 2012/05552–9; Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), under Grant 456089/2014–4; the HYPER project of the CONSOLIDER-INGENIO 2010 program of Spain, under Grant CSD2009–00067; the XoSoft project, Soft modular biomimetic exoskeleton to assist people with mobility impairments, contract H2020– ICT24–2016–688175; and by a grant from the Flemish agency for Innovation by Science and Technology (MIRAD, IWT–SBO 120057).Peer reviewe

    Nitrogen Oxides (NOx) in the Arctic Troposphere at Ny-Ã…lesund (Svalbard Islands): Effects of Anthropogenic Pollution Sources

    Get PDF
    Atmospheric measurements of nitrogen oxides (NOx = NO + NO2), ozone (O3) and other constituents were carried out during three field campaigns (29 March–30 April 2010, 1–26 April 2011, 18 May–8 October 2015) at Ny-Ålesund. The study focused on the variability of important O3 precursors, such as NOx, in the Arctic troposphere, and on the impact from anthropogenic sources on their measured concentrations: higher NO and NO2 levels were mostly associated with the lowest wind speeds and northern directions, indicating local pollution. Long-range transported sources from Russia and Europe were also identified with an occurrence of high NOx levels. Several ozone depletion events were observed and associated to winds blowing from the north-west direction (Arctic Ocean). Most of these events were connected to the lower NO and NO2 concentrations. Measurements of halogen and low molecular weight carbonyl compounds in 2010 and 2011, respectively, showed variable effects during the ozone depletion events. Other data, such as high time-resolved radon progeny measurements, were used in 2015 to identify source tracking and transport of air masses, local effects and atmospheric stability dynamics that could influence the NOx concentrations at Ny-Ålesund

    Improved Time-Resolved Measurements of Inorganic Ions in Particulate Matter by PILS-IC Integrated with a Sample Pre-Concentration System

    No full text
    <div><p>A particle-into-liquid sampler coupled with ion chromatograph (PILS-IC) for the on-line measurement of inorganic ions has been modified by the insertion of two ion-exchange pre-concentration cartridges that enrich the sample during the period of the IC analysis. The limits of detection of the modified instrument were 10-15 times lower and the time coverage 24 times higher (from 2 to 48 min per hour) than those of the original PILS-IC setup. The instrumental performance in terms of recovery and break-through volume from the cartridges was satisfactory. The modified PILS-IC was operated in comparison with a diffusion denuder line and with a high-resolution time-of-flight aerosol mass spectrometer (HR-TOF-AMS) during a short intensive measurement period organized in the framework of the European Monitoring and Evaluation Programme (EMEP), a co-operative program for monitoring and evaluation of the long-range transmission of the air pollutants in Europe. The instrument showed a quantitative response in agreement with the results of the diffusion lines, and an ability to trace fine concentration variations not so different from the performance of the much more complex HR-TOF-AMS. From the time patterns of the ion concentrations measured by the modified PILS-IC, it was possible to obtain useful information about the variations in the air quality and in the strength of the particulate matter sources.</p><p>Copyright 2015 American Association for Aerosol Research</p></div
    corecore