186 research outputs found

    Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.

    Get PDF
    PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm

    Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.

    Get PDF
    PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm

    Multimodality Treatment for Early-Stage Hepatocellular Carcinoma: A Bridging Therapy for Liver Transplantation

    Get PDF
    Purpose: To evaluate the efficiency of a multimodality approach consisting of transcatheter arterial chemoembolization (TACE) and radiofrequency ablation (RFA) as bridging therapy for patients with hepatocellular carcinoma (HCC) awaiting orthotopic liver transplantation (OLT) and to evaluate the histopathological response in explant specimens. Materials and Methods: Between April 2001 and November 2011, 36 patients with 50 HCC nodules (1.4-5.0 cm, median 2.8 cm) on the waiting list for liver transplantation were treated by TACE and RFA. The drop-out rate during the follow-up period was recorded. The local efficacy was evaluated by histopathological examination of the explanted livers. Results: During a median follow-up time of 29 (4.0-95.3) months the cumulative drop-out rate for the patients on the waiting list was 0, 2.8, 5.5, 11.0, 13.9 and 16.7% at 3, 6, 12, 24, 36 and 48 months, respectively. 16 patients (with 26 HCC lesions) out of 36(44.4%) were transplanted by the end of study with a median waiting list time of 13.7 (2.5-37.8) months. The histopathological examination of the explanted specimens revealed a complete necrosis in 20 of 26 HCCs (76.9%), whereas 6 (23.1%) nodules showed viable residual tumor tissue. All transplanted patients are alive at a median time of 29.9 months. Imaging correlation showed 100% specificity and 66.7% sensitivity for the depiction of residual or recurrent tumor. Conclusion: We conclude that TACE.combined with RFA could provide an effective treatment to decrease the drop-out rate from the OLT waiting list for HCC patients. Furthermore, this combination therapy results in high rates of complete tumor necrosis as evaluated in the histopathological analysis of the explanted livers. Further randomized trials are needed to demonstrate if there is a benefit in comparison with a single-treatment approach. copyright (C) 2012 S. Karger AG, Base

    Women in radiology: gender diversity is not a metric—it is a tool for excellence

    Get PDF
    Abstract: Women in Focus: Be Inspired was a unique programme held at the 2019 European Congress of Radiology that was structured to address a range of topics related to gender and healthcare, including leadership, mentoring and the generational progression of women in medicine. In most countries, women constitute substantially fewer than half of radiologists in academia or private practice despite frequently accounting for at least half of medical school enrolees. Furthermore, the proportion of women decreases at higher academic ranks and levels of leadership, a phenomenon which has been referred to as a “leaky pipeline”. Gender diversity in the radiologic workplace, including in academic and leadership positions, is important for the present and future success of the field. It is a tool for excellence that helps to optimize patient care and research; moreover, it is essential to overcome the current shortage of radiologists. This article reviews the current state of gender diversity in academic and leadership positions in radiology internationally and explores a wide range of potential reasons for gender disparities, including the lack of role models and mentorship, unconscious bias and generational changes in attitudes about the desirability of leadership positions. Strategies for both individuals and institutions to proactively increase the representation of women in academic and leadership positions are suggested. Key Points: • Gender-diverse teams perform better. Thus, gender diversity throughout the radiologic workplace, including in leadership positions, is important for the current and future success of the field. • Though women now make up roughly half of medical students, they remain underrepresented among radiology trainees, faculty and leaders. • Factors leading to the gender gap in academia and leadership positions in Radiology include a lack of role models and mentors, unconscious biases, other societal barriers and generational changes

    TC multicorte (TCMC) cardiaca: aplicaciones clínicas

    Get PDF
    La introducción de los equipos de TC multicorte y el desarrollo de técnicas de adquisición de imágenes con sincronización electrocardiográfica y reconstrucción retrospectiva han permitido que la TC multicorte cardiaca se pueda considerar hoy en día una técnica no invasiva muy útil para el estudio de la patología cardiaca en la práctica clínica diaria. La valoración de las arterias coronarias es una de las principales aplicaciones clínicas de esta técnica diagnóstica e incluye la detección y cuantificación del calcio coronario, la coronariografía por TC multicorte (estudio de la anatomía coronaria, variantes anatómicas y anomalías del origen y trayecto), la valoración angiográfica de la permeabilidad de injertos aortocoronarios y endoprótesis vasculares y la caracterización de las placas de ateroma. Los nuevos programas de reconstrucción y postprocesamiento permiten obtener, además, parámetros de morfología y contracción miocárdica y función cardiaca. Otras aplicaciones clínicas incluyen la caracterización de masas cardiacas intracavitarias y la valoración del pericardio.Since the introduction of last generation multislice MSCT systems and the development of simultaneous electrocardiographic-tracing image acquisition and retrospective reconstruction techniques into clinical routine, cardiac MSCT has been considered a very useful non-invasive technique for the study of cardiac pathology in the daily clinical practice. One of the main clinical applications of this diagnostic technique is the evaluation of the coronary arteries including detection and quantification of coronary calcium, multislice CT coronary angiography (anatomy, anatomical variants and anomalies of the origin and course), the angiographic evaluation of the patency of aortocoronary by-pass grafts and coronary stents, and plaque characterization. The new reconstruction and postprocessing programs allow to obtain, in addition, parameters of myocardial morphology and contraction and cardiac function. Other clinical applications include the characterization of cardiac masses and the evaluation of the pericardium

    Multimodality Treatment with Conventional Transcatheter Arterial Chemoembolization and Radiofrequency Ablation for Unresectable Hepatocellular Carcinoma

    Get PDF
    Background/Aims: To evaluate the efficacy of multimodality treatment consisting of conventional transcatheter arterial chemoembolization (TACE) and radiofrequency ablation (RFA) in patients with non-resectable and non-ablatable hepatocellular carcinoma (HCC). Methods: In this retrospective study, 85 consecutive patients with HCC (59 solitary, 29 multifocal HCC) received TACE followed by RFA between 2001 and 2010. The mean number of tumors per patient was 1.6 +/- 0.7 with a mean size of 3.0 +/- 0.9 cm. Both local efficacy and patient survival were evaluated. Results: Of 120 treated HCCs, 99 (82.5%) showed a complete response (CR), while in 21 HCCs (17.5%) a partial response was depicted. Patients with solitary HCC revealed CR in 91% (51/56); in patients with multifocal HCC (n = 29) CR was achieved in 75% (48 of 64 HCCs). The median survival for all patients was 25.5 months. The 1-, 2-, 3- and 5-year survival rates were 84.6, 58.7, 37.6 and 14.6%, respectively. Statistical analysis revealed a significant difference in survival between Barcelona Clinic Liver Cancer (BCLC) A (73.4 months) and B (50.3 months) patients, while analyses failed to show a difference for Child-Pugh score, Cancer of Liver Italian Program (CLIP) score and tumor distribution pattern. Conclusion: TACE combined with RFA provides an effective treatment approach with high local tumor control rates and promising survival data, especially for BCLC A patients. Randomized trials are needed to compare this multimodality approach with a single modality approach for early-stage HCC. Copyright (C) 2011 S. Karger AG, Base

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)
    corecore