22 research outputs found

    Lung Segmentation in 4D CT Volumes Based on Robust Active Shape Model Matching

    Get PDF
    Dynamic and longitudinal lung CT imaging produce 4D lung image data sets, enabling applications like radiation treatment planning or assessment of response to treatment of lung diseases. In this paper, we present a 4D lung segmentation method that mutually utilizes all individual CT volumes to derive segmentations for each CT data set. Our approach is based on a 3D robust active shape model and extends it to fully utilize 4D lung image data sets. This yields an initial segmentation for the 4D volume, which is then refined by using a 4D optimal surface finding algorithm. The approach was evaluated on a diverse set of 152 CT scans of normal and diseased lungs, consisting of total lung capacity and functional residual capacity scan pairs. In addition, a comparison to a 3D segmentation method and a registration based 4D lung segmentation approach was performed. The proposed 4D method obtained an average Dice coefficient of 0.9773±0.0254, which was statistically significantly better (p value ≪0.001) than the 3D method (0.9659±0.0517). Compared to the registration based 4D method, our method obtained better or similar performance, but was 58.6% faster. Also, the method can be easily expanded to process 4D CT data sets consisting of several volumes

    Robust Initialization of Active Shape Models for Lung Segmentation in CT Scans: A Feature-Based Atlas Approach

    Get PDF
    Model-based segmentation methods have the advantage of incorporating a priori shape information into the segmentation process but suffer from the drawback that the model must be initialized sufficiently close to the target. We propose a novel approach for initializing an active shape model (ASM) and apply it to 3D lung segmentation in CT scans. Our method constructs an atlas consisting of a set of representative lung features and an average lung shape. The ASM pose parameters are found by transforming the average lung shape based on an affine transform computed from matching features between the new image and representative lung features. Our evaluation on a diverse set of 190 images showed an average dice coefficient of 0.746 ± 0.068 for initialization and 0.974 ± 0.017 for subsequent segmentation, based on an independent reference standard. The mean absolute surface distance error was 0.948 ± 1.537 mm. The initialization as well as segmentation results showed a statistically significant improvement compared to four other approaches. The proposed initialization method can be generalized to other applications employing ASM-based segmentation

    Comparative Study With New Accuracy Metrics for Target Volume Contouring in PET Image Guided Radiation Therapy

    Get PDF
    [EN] The impact of positron emission tomography (PET) on radiation therapy is held back by poor methods of defining functional volumes of interest. Many new software tools are being proposed for contouring target volumes but the different approaches are not adequately compared and their accuracy is poorly evaluated due to the ill-definition of ground truth. This paper compares the largest cohort to date of established, emerging and proposed PET contouring methods, in terms of accuracy and variability. We emphasize spatial accuracy and present a new metric that addresses the lack of unique ground truth. Thirty methods are used at 13 different institutions to contour functional volumes of interest in clinical PET/CT and a custom-built PET phantom representing typical problems in image guided radiotherapy. Contouring methods are grouped according to algorithmic type, level of interactivity and how they exploit structural information in hybrid images. Experiments reveal benefits of high levels of user interaction, as well as simultaneous visualization of CT images and PET gradients to guide interactive procedures. Method-wise evaluation identifies the danger of over-automation and the value of prior knowledge built into an algorithm.For retrospective patient data and manual ground truth delineation, the authors wish to thank S. Suilamo, K. Lehtio, M. Mokka, and H. Minn at the Department of Oncology and Radiotherapy, Turku University Hospital, Finland. This study was funded by the Finnish Cancer Organisations.Shepherd, T.; Teräs, M.; Beichel, RR.; Boellaard, R.; Bruynooghe, M.; Dicken, V.; Gooding, MJ.... (2012). Comparative Study With New Accuracy Metrics for Target Volume Contouring in PET Image Guided Radiation Therapy. IEEE Transactions on Medical Imaging. 31(12):2006-2024. doi:10.1109/TMI.2012.2202322S20062024311

    FDG PET based prediction of response in head and neck cancer treatment: Assessment of new quantitative imaging features.

    No full text
    Introduction18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is now a standard diagnostic imaging test performed in patients with head and neck cancer for staging, re-staging, radiotherapy planning, and outcome assessment. Currently, quantitative analysis of FDG PET scans is limited to simple metrics like maximum standardized uptake value, metabolic tumor volume, or total lesion glycolysis, which have limited predictive value. The goal of this work was to assess the predictive potential of new (i.e., nonstandard) quantitative imaging features on head and neck cancer outcome.MethodsThis retrospective study analyzed fifty-eight pre- and post-treatment FDG PET scans of patients with head and neck squamous cell cancer to calculate five standard and seventeen new features at baseline and post-treatment. Cox survival regression was used to assess the predictive potential of each quantitative imaging feature on disease-free survival.ResultsAnalysis showed that the post-treatment change of the average tracer uptake in the rim background region immediately adjacent to the tumor normalized by uptake in the liver represents a novel PET feature that is associated with disease-free survival (HR 1.95; 95% CI 1.27, 2.99) and has good discriminative performance (c index 0.791).ConclusionThe reported findings define a promising new direction for quantitative imaging biomarker research in head and neck squamous cell cancer and highlight the potential role of new radiomics features in oncology decision making as part of precision medicine
    corecore