63 research outputs found

    Innovación verde a nivel industrial: una revisión sistemática

    Get PDF
    The Green innovation describes to the evolution of humanity toward capacity of invention to technological and environmental change for cleaner production and sustainable development. The existing literature about this concept is recent and no systematic review of the literature on the topic. The objective of this study is to synthesize the existing literature on Green innovation and identifies concepts and applications in the industries, based on the specialized search - Scopus database. The systematic literature review was conducted, including 24 articles. Despite of the research the relationship between green innovation in companies remains unclear but in the construction sector the green innovation can be a potential sector with ability to lead the process sustainable and responsibilities to the environment since conception, construction, use and disposal the structure.La innovación verde describe la evolución de la humanidad hacia la capacidad de invención para un cambio tecnológico y ambiental y para una producción más limpia y un desarrollo sostenible. La literatura existente sobre el tema es reciente y no hay una revisión sistemática de la literatura. El objetivo de este estudio es sintetizar la literatura existente sobre innovación verde e identificar conceptos y aplicaciones en las industrias, en base a la búsqueda especializada de la base de datos Scopus. Se realizó una revisión sistemática de la literatura, que incluyó 24 artículos. A pesar de las investigaciones, la relación entre la innovación verde en las empresas sigue sin estar clara, pero en el sector de la construcción, la innovación verde puede ser un sector potencial con capacidad para liderar el proceso de manera sostenible y responsable con el medio ambiente desde la concepción, construcción, uso y eliminación de la estructura

    ANÁLISE E OTIMIZAÇÃO TERMOECONÔMICA DO CICLO KALINA KCS1 PARA A RECUPERAÇÃO DE CALOR RESIDUAL EM UMA FÁBRICA DE CIMENTO

    Get PDF
    A análise termoeconômica do ciclo Kalina KCS1 para a recuperação de calor residual (RCR) tem por objetivo estimar o custo de geração da energia elétrica e a potência líquida gerada. A disponibilidade energética para a geração baseou-se nos dados de energia residual nos pré-aquecedores ciclônicos de uma usina cimenteira com capacidade diária de 3.500 toneladas de clínquer. Foi elaborado um modelo no Engineering Equation Solver (EES) para a simulação do ciclo que contém todos os balanços de massa, energia, entropia e exergia para todos os componentes do ciclo, além da estimativa do custo de geração do sistema. A otimização do ciclo visando maximizar a geração de energia com o mínimo custo de geração foi realizada. A condição ótima do ciclo foi calculada a partir de diversas funções objetivo. Os resultados permitem indicar a faixa de valores das variáveis independentes nas quais se localiza a região de ótimo visando à máxima geração com o mínimo custo, observando-se a forte influência da concentração de amônia no condensador e da pressão do vapor na entrada da turbina. O valor de geração máximo obtido da ordem 2.776 kW e os custos de geração mínimo na faixa de R$ 150/MWh mostram a competitividade deste ciclo

    Transcatheter pulmonary valve implantation: systematic literature review

    Get PDF
    Surgical repair of some complex congenital heart diseases involves reconstruction of the right ventricular outflow tract using homografts, bioprostheses, bovine jugular grafts or other valved conduits between the right ventricle and the main pulmonary artery. Although these surgical procedures may be performed with low mortality rates, the life span of these implanted valves or conduits is usually short (< 10 years) due to either degeneration and/or calcification. Variable degrees of pulmonary stenosis, often associated with pulmonary insufficiency, are consequences of conduit degeneration. In 2000, Bonhoeffer et al. were the first to report the transcatheter pulmonary valve implantation (TPVI) of a bioprosthetic pulmonary valve later named Melody® valve (Medtronic, Minneapolis, USA). The technique was initially developed to limit the need for multiple surgical procedures, and, ultimately, to work as a surrogate of a new surgical valve replacement. Subsequent clinical studies in Europe and the United States confirmed the safety and efficacy of this technique in a larger number of patients. Since the National Sanitary Surveillance Agency (Agência Nacional de Vigilância Sanitária - Anvisa) granted approval for clinical use of the Melody® transcatheter pulmonary biological valve in February 2103, we deemed that a judicious assessment of this new technology was timely and necessary before the widespread use in our country. The objective of this study was to perform a systematic literature review on the use of TPVI in patients with dysfunctional homografts, valved conduits and bioprostheses implanted surgically in the right ventricular outflow tract.A correção cirúrgica de algumas cardiopatias congênitas complexas envolve a reconstrução da via de saída do ventrículo direito com a interposição de homoenxertos, biopróteses, enxertos de jugular bovina ou outros condutos valvulados entre o ventrículo direito e o tronco da artéria pulmonar. Apesar de essas cirurgias poderem ser realizadas com baixa mortalidade, a vida útil das válvulas ou dos condutos implantados é normalmente pequena (< 10 anos), seja por degeneração e/ou calcificação. Graus variáveis de estenose pulmonar na maioria das vezes associada a insuficiência pulmonar são consequências da degeneração dos condutos. Em 2000, Bonhoeffer et al. foram os primeiros a relatar o implante transcateter de bioprótese valvular pulmonar (ITVP) com um dispositivo que posteriormente foi denominado de válvula Melody® (Medtronic, Minneapolis, Estados Unidos). A técnica foi inicialmente desenvolvida para limitar a necessidade de múltiplos procedimentos cirúrgicos, substituindo, em última análise, uma nova troca cirúrgica valvular. Estudos subsequentes na Europa e Estados Unidos atestaram para a segurança e eficácia dessa técnica em um número maior de pacientes. Como a Agência Nacional de Vigilância Sanitária (Anvisa) concedeu a aprovação para o uso clínico da válvula biológica pulmonar transcateter Melody® em fevereiro de 2013, consideramos necessária e oportuna a avaliação judiciosa da utilização dessa nova tecnologia antes que ela fosse aplicada em larga escala em nosso país. O objetivo deste estudo foi realizar uma revisão sistemática da literatura sobre o ITVP em pacientes com disfunções de homoenxertos, condutos valvulados e biopróteses implantados cirurgicamente na via de saída do ventrículo direito.Evidências - Credibilidade CientíficaHospital da Unimed João PessoaFundação Universitária de Cardiologia Instituto de Cardiologia Setor de Cardiologia Intervencionista em Cardiopatias CongênitasComplexo Hospitalar Santa Casa de Porto Alegre Serviço de Cardiologia Pediátrica e Cardiologia IntervencionistaHospital Beneficência Portuguesa de São Paulo Setor de Intervenções em Cardiopatias CongênitasUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Setor de Cardiologia PediátricaInstituto Dante Pazzanese de Cardiologia Seção Médica de Intervenções em Valvopatias AdquiridasUniversidade Federal de Minas Gerais Hospital de Clinicas Departamento de Cardiopatias CongênitasHospital Laranjeiras Instituto Nacional de Cardiologia Serviço de Cardiologia da Criança e do AdolescenteHospital Federal dos Servidores do Estado Setor de Cardiologia Intervencionista dos Defeitos Estruturais e CongênitosInstituto de Medicina Integral Prof. Fernando Figueira Setor de Hemodinâmica em Cardiopatias CongênitasHospital Biocor Departamento de Cardiologia Pediátrica IntervencionistaInstituto Dante Pazzanese de Cardiologia Seção Médica de Intervenções em Cardiopatias CongênitasUNIFESP, EPM, Setor de Cardiologia PediátricaSciEL

    Calidad microbiológica de las aguas termales del balneario “El Tingo”. Pichincha. Ecuador

    Get PDF
    Objective: The purpose of research was determining the microbiological quality of the thermal water of the “El Tingo” Spa, located at 2500 mamsl, Pichincha Province, Ecuador. Methods: Four samplings were carried out at different times of the year and in two areas of the Spa. The physicochemical parameters (conductivity, hardness, dissolved oxygen, pH, dissolved solids and tempe­rature) were determined “in situ”. The heterotrophic bacteria, coliforms and molds was determined, as well as the identification of the isolated strains according to the indicated by MacFaddin (2004). Results: The Tingo thermal water is classified as very strong conductivity, excessive mineralization, very hard water, with very little dissolved oxygen, neutral pH and hyperthermal. The average count of he­terotrophic bacteria in the water contained in the cistern of the spa were 2.10 x 102 CFU / mL, coliforms 0.30 x 10 CFU / mL and fungi1,00 x 10 CFU / mL. For the thermal water showers, the average values were 2.42 x 102 CFU/ mL of heterotrophic bacteria, 0.85 x 10 CFU / mL coliforms and 0.68 x 10 CFU/ mLfungi. Escherichia coli were not detectedin any of the samples. It was possible to identify 14 Gram negative strains of the genus Aeromonas, Burkholderia, Citrobacter and Pseudomonas, 5 Gram positive of the genera Bacillus and Staphylococcus and 2 fungal strains of the genus Aspergillus.Objetivo. El proposito del trabajo fue determinar la calidad microbiologica del agua termal del Balneario “El Tingo”, situado a 2500 msnm, Provincia de Pichincha, Ecuador. Metodo. Se realizaron cuatro muestreos en diferentes epocas del año y en dos zonas del Balneario. Se determinaron “in situ” los parametros fisicoquimicos (conductividad, dureza, oxigeno disuelto, pH, solidos disueltos y temperatura), utilizando de una sonda multiparámetro. La cuantificacion de bacterias heterotrofas, coliformes y mohos se hizo en placas PetrifilmTM. La identificacion taxonomica de las cepas aisladas se realizo de acuerdo a lo indicado por  Andueza (2007).  Resultados. Los resultados  indican que el agua termal del Tingo se clasifican como de conductividad muy fuerte, mineralización excesiva, aguas muy duras, con muy poco oxigeno disuelto, pH neutro e hipertermales. El contaje promedio de bacterias heterótrofas en el agua contenida en la cisterna del balneario fue de 2,11 x 102 UFC/mL, coliformes 3,00 UFC/mL y mohos 2,00 x 10 UFC/mL. Para las duchas de agua termal los valores promedios fueron de 2,33 x 102 UFC/mL de bacterias heterótrofas, 1,60 x 10 UFC/mL coliformes y 1,70 x10 UFC/mL de mohos. No se detectó la presencia de coliformes fecales. Se identificaron 14 cepas Gram negativas de los géneros Aeromonas, Burkholderia, Citrobacter y Pseudomonas, 5 Gram positivas de los géneros Bacillus y Staphylococcus y 2 cepas fúngicas del género Aspergillus Conclusiones. Los resultados obtenidos demuestran una población microbiana escasa y poco diversa, lo que implica una buena calidad del agua y de los acuífero

    NG2 antigen is a therapeutic target for MLL-rearranged B-cell acute lymphoblastic leukemia

    Get PDF
    Altres ajuts: This work has been supported by the Asociación Española Contra el Cáncer (AECC), Beca FERO, and OM are supported by postdoctoral fellowships from the AECC scientific foundation and the Catalunya Government (Beatriu de Pinos, BP00048), respectively. PM also acknowledges the financial support from the Obra Social La Caixa-Fundaciò Josep Carreras and "Premio Miguelín".B cell acute lymphoblastic leukemia (B-ALL) is the most common childhood cancer, with cure rates of ∼80%. MLL-rearranged (MLLr) B-ALL (MLLr-B-ALL) has, however, an unfavorable prognosis with common therapy refractoriness and early relapse, and therefore new therapeutic targets are needed for relapsed/refractory MLLr-B-ALL. MLLr leukemias are characterized by the specific expression of chondroitin sulfate proteoglycan-4, also known as neuron-glial antigen-2 (NG2). NG2 was recently shown involved in leukemia invasiveness and central nervous system infiltration in MLLr-B-ALL, and correlated with lower event-free survival (EFS). We here hypothesized that blocking NG2 may synergize with established induction therapy for B-ALL based on vincristine, glucocorticoids, and l-asparaginase (VxL). Using robust patient-derived xenograft (PDX) models, we found that NG2 is crucial for MLLr-B-ALL engraftment upon intravenous (i.v.) transplantation. In vivo blockade of NG2 using either chondroitinase-ABC or an anti-NG2-specific monoclonal antibody (MoAb) resulted in a significant mobilization of MLLr-B-ALL blasts from bone marrow (BM) to peripheral blood (PB) as demonstrated by cytometric and 3D confocal imaging analysis. When combined with either NG2 antagonist, VxL treatment achieved higher rates of complete remission, and consequently higher EFS and delayed time to relapse. Mechanistically, anti-NG2 MoAb induces neither antibody-dependent cell-mediated not complement-dependent cytotoxicity. NG2 blockade rather overrides BM stroma-mediated chemoprotection through PB mobilization of MLLr-B-ALL blasts, thus becoming more accessible to chemotherapy. We provide a proof of concept for NG2 as a therapeutic target for MLLr-B-ALL

    Phenotypical, Clinical, and Molecular Aspects of Adults and Children With Homozygous Familial Hypercholesterolemia in Iberoamerica

    Get PDF
    Fil: Alves, Ana Catarina. Instituto Nacional de Saúde Doutor Ricardo Jorge, Lisboa; Portugal.Fil: Alonso, Rodrigo. Center for Advanced Metabolic Medicine and Nutrition, Santiago; Chile.Fil: Diaz-Diaz, José Luís. Hospital Universitario A Coruña. Department of Internal Medicine; España.Fil: Medeiros, Ana Margarida. Instituto Nacional de Saúde Doutor Ricardo Jorge, Lisboa; Portugal.Fil: Jannes, Cinthia E. University of São Paulo. Medical School. Hospital São Paulo. Heart Institute (InCor); Brasil.Fil: Merchan, Alonso. Fundación Clinica SHAIO, Cardiología, Bogotá; Colombia.Fil: Vasques-Cardenas, Norma A. Universidad Autónoma de Guadalajara. Facultad de Medicina Zapopan; México.Fil: Cuevas, Ada. Center for Advanced Metabolic Medicine and Nutrition, Santiago; Chile.Fil: Chacra, Ana Paula. University of São Paulo. Medical School. Hospital São Paulo. Heart Institute (InCor); Brasil.Fil: Krieger, Jose E. University of São Paulo. Medical School. Hospital São Paulo. Heart Institute (InCor); Brasil.Fil: Arroyo, Raquel. Fundación Hipercolesterolemia Familiar, Madrid; España.Fil: Arrieta, Francisco. Hospital Ramón y Cajal. Departamento de Endocrinología, Madrid; España.Fil: Schreier, Laura. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Departamento de Bioquímica Clínica, Laboratorio de Lípidos y Aterosclerosis; Argentina.Fil: Corral, Pablo. Universidad FASTA. Facultad de Medicina. Cátedra Farmacología e Investigación, Mar del Plata; Argentina.Fil: Bañares, Virginia. ANLIS Dr.C.G.Malbrán. Centro Nacional de Genética Médica. Departamento de Genética Experimental; Argentina.Fil: Araujo, Maria B. Hospital Garrahan. Servicio de Nutrición; Argentina.Fil: Bustos, Paula. Universidad de Concepción. Facultad de Farmacia; Chile.Fil: Asenjo, Sylvia. Universidad de Concepción. Facultad de Medicina; Chile.Fil: Stoll, Mario. Programa GENYCO, Laboratorio de Genética Molecular. Comisión Honoraria de Salud Cardiovascular, Montevideo; Uruguay.Fil: Dell'Oca, Nicolás. Programa GENYCO, Laboratorio de Genética Molecular. Comisión Honoraria de Salud Cardiovascular, Montevideo; Uruguay.Fil: Reyes, Maria. Fundación Cardiovascular de Colombia. Cardiología; Bogotá.Fil: Ressia, Andrés. Fundación Cardiovascular de Colombia. Cardiología; Bogotá.Fil: Campo, Rafael. Instituto Mexicano del Seguro Social. Centro de Investigación Biomédica del Occidente, Guadalajara; México.Fil: Magaña-Torres, Maria T. Instituto Nacional de Ciencias Médicas y Nutrición. Unidad de Investigación de Enfermedades Metabólicas; México.Fil: Metha, Roopa. Instituto Nacional de Ciencias Médicas y Nutrición. Unidad de Investigación de Enfermedades Metabólicas; México.Fil: Aguilar-Salinas, Carlos A. Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán. Departamento de Endocrinología y Metabolismo. Secretaría de la Defensa Nacional. Unidad de Especialidades Médicas. Servicio de Endocrinología; México.Fil: Ceballos-Macias, José J. Pontificia Universidad Javerina. Facultad de Medicina. Departamento de Medicina Interna, Bogotá; Colombia.Fil: Ruiz Morales, Álvaro J. Pontificia Universidad Javerina. Facultad de Medicina. Departamento de Medicina Interna, Bogotá; Colombia.Fil: Mata, Pedro. Fundación Hipercolesterolemia Familiar, Madrid; España.Fil: Bourbon, Mafalda. Instituto Nacional de Saúde Doutor Ricardo Jorge, Lisboa; Portugal.Fil: Santos, Raul D. University of São Paulo. Medical School. Hospital São Paulo. Heart Institute (InCor); Brasil.OBJECTIVE: Characterize homozygous familial hypercholesterolemia (HoFH) individuals from Iberoamerica. APPROACH AND RESULTS: In a cross-sectional retrospective evaluation 134 individuals with a HoFH phenotype, 71 adults (age 39.3±15.8 years, 38.0% males), and 63 children (age 8.8±4.0 years, 50.8% males) were studied. Genetic characterization was available in 129 (96%). The majority (91%) were true homozygotes (true HoFH, n=79, 43.0% children, 46.8% males) or compound heterozygotes (compound heterozygous familial hypercholesterolemia, n=39, 51.3% children, 46.2% males) with putative pathogenic variants in the LDLR. True HoFH due to LDLR variants had higher total (P=0.015) and LDL (low-density lipoprotein)-cholesterol (P=0.008) compared with compound heterozygous familial hypercholesterolemia. Children with true HoFH (n=34) tended to be diagnosed earlier (P=0.051) and had a greater frequency of xanthomas (P=0.016) than those with compound heterozygous familial hypercholesterolemia (n=20). Previous major cardiovascular events were present in 25 (48%) of 52 children (missing information in 2 cases), and in 43 (67%) of 64 adults with LDLR variants. Children who are true HoFH had higher frequency of major cardiovascular events (P=0.02), coronary heart (P=0.013), and aortic/supra-aortic valve diseases (P=0.022) than compound heterozygous familial hypercholesterolemia. In adults, no differences were observed in major cardiovascular events according to type of LDLR variant. From 118 subjects with LDLR variants, 76 (64%) had 2 likely pathogenic or pathogenic variants. In 89 subjects with 2 LDLR variants, those with at least one null allele were younger (P=0.003) and had a greater frequency of major cardiovascular events (P=0.038) occurring at an earlier age (P=0.001). CONCLUSIONS: There was a high frequency of cardiovascular disease even in children. Phenotype and cardiovascular complications were heterogeneous and associated with the type of molecular defect

    The evolution of the ventilatory ratio is a prognostic factor in mechanically ventilated COVID-19 ARDS patients

    Get PDF
    Background: Mortality due to COVID-19 is high, especially in patients requiring mechanical ventilation. The purpose of the study is to investigate associations between mortality and variables measured during the first three days of mechanical ventilation in patients with COVID-19 intubated at ICU admission. Methods: Multicenter, observational, cohort study includes consecutive patients with COVID-19 admitted to 44 Spanish ICUs between February 25 and July 31, 2020, who required intubation at ICU admission and mechanical ventilation for more than three days. We collected demographic and clinical data prior to admission; information about clinical evolution at days 1 and 3 of mechanical ventilation; and outcomes. Results: Of the 2,095 patients with COVID-19 admitted to the ICU, 1,118 (53.3%) were intubated at day 1 and remained under mechanical ventilation at day three. From days 1 to 3, PaO2/FiO2 increased from 115.6 [80.0-171.2] to 180.0 [135.4-227.9] mmHg and the ventilatory ratio from 1.73 [1.33-2.25] to 1.96 [1.61-2.40]. In-hospital mortality was 38.7%. A higher increase between ICU admission and day 3 in the ventilatory ratio (OR 1.04 [CI 1.01-1.07], p = 0.030) and creatinine levels (OR 1.05 [CI 1.01-1.09], p = 0.005) and a lower increase in platelet counts (OR 0.96 [CI 0.93-1.00], p = 0.037) were independently associated with a higher risk of death. No association between mortality and the PaO2/FiO2 variation was observed (OR 0.99 [CI 0.95 to 1.02], p = 0.47). Conclusions: Higher ventilatory ratio and its increase at day 3 is associated with mortality in patients with COVID-19 receiving mechanical ventilation at ICU admission. No association was found in the PaO2/FiO2 variation

    Clustering COVID-19 ARDS patients through the first days of ICU admission. An analysis of the CIBERESUCICOVID Cohort

    Full text link
    Background Acute respiratory distress syndrome (ARDS) can be classified into sub-phenotypes according to different inflammatory/clinical status. Prognostic enrichment was achieved by grouping patients into hypoinflammatory or hyperinflammatory sub-phenotypes, even though the time of analysis may change the classification according to treatment response or disease evolution. We aimed to evaluate when patients can be clustered in more than 1 group, and how they may change the clustering of patients using data of baseline or day 3, and the prognosis of patients according to their evolution by changing or not the cluster.Methods Multicenter, observational prospective, and retrospective study of patients admitted due to ARDS related to COVID-19 infection in Spain. Patients were grouped according to a clustering mixed-type data algorithm (k-prototypes) using continuous and categorical readily available variables at baseline and day 3.Results Of 6205 patients, 3743 (60%) were included in the study. According to silhouette analysis, patients were grouped in two clusters. At baseline, 1402 (37%) patients were included in cluster 1 and 2341(63%) in cluster 2. On day 3, 1557(42%) patients were included in cluster 1 and 2086 (57%) in cluster 2. The patients included in cluster 2 were older and more frequently hypertensive and had a higher prevalence of shock, organ dysfunction, inflammatory biomarkers, and worst respiratory indexes at both time points. The 90-day mortality was higher in cluster 2 at both clustering processes (43.8% [n = 1025] versus 27.3% [n = 383] at baseline, and 49% [n = 1023] versus 20.6% [n = 321] on day 3). Four hundred and fifty-eight (33%) patients clustered in the first group were clustered in the second group on day 3. In contrast, 638 (27%) patients clustered in the second group were clustered in the first group on day 3.Conclusions During the first days, patients can be clustered into two groups and the process of clustering patients may change as they continue to evolve. This means that despite a vast majority of patients remaining in the same cluster, a minority reaching 33% of patients analyzed may be re-categorized into different clusters based on their progress. Such changes can significantly impact their prognosis

    Atrasentan and renal events in patients with type 2 diabetes and chronic kidney disease (SONAR): a double-blind, randomised, placebo-controlled trial

    Get PDF
    Background: Short-term treatment for people with type 2 diabetes using a low dose of the selective endothelin A receptor antagonist atrasentan reduces albuminuria without causing significant sodium retention. We report the long-term effects of treatment with atrasentan on major renal outcomes. Methods: We did this double-blind, randomised, placebo-controlled trial at 689 sites in 41 countries. We enrolled adults aged 18–85 years with type 2 diabetes, estimated glomerular filtration rate (eGFR)25–75 mL/min per 1·73 m 2 of body surface area, and a urine albumin-to-creatinine ratio (UACR)of 300–5000 mg/g who had received maximum labelled or tolerated renin–angiotensin system inhibition for at least 4 weeks. Participants were given atrasentan 0·75 mg orally daily during an enrichment period before random group assignment. Those with a UACR decrease of at least 30% with no substantial fluid retention during the enrichment period (responders)were included in the double-blind treatment period. Responders were randomly assigned to receive either atrasentan 0·75 mg orally daily or placebo. All patients and investigators were masked to treatment assignment. The primary endpoint was a composite of doubling of serum creatinine (sustained for ≥30 days)or end-stage kidney disease (eGFR <15 mL/min per 1·73 m 2 sustained for ≥90 days, chronic dialysis for ≥90 days, kidney transplantation, or death from kidney failure)in the intention-to-treat population of all responders. Safety was assessed in all patients who received at least one dose of their assigned study treatment. The study is registered with ClinicalTrials.gov, number NCT01858532. Findings: Between May 17, 2013, and July 13, 2017, 11 087 patients were screened; 5117 entered the enrichment period, and 4711 completed the enrichment period. Of these, 2648 patients were responders and were randomly assigned to the atrasentan group (n=1325)or placebo group (n=1323). Median follow-up was 2·2 years (IQR 1·4–2·9). 79 (6·0%)of 1325 patients in the atrasentan group and 105 (7·9%)of 1323 in the placebo group had a primary composite renal endpoint event (hazard ratio [HR]0·65 [95% CI 0·49–0·88]; p=0·0047). Fluid retention and anaemia adverse events, which have been previously attributed to endothelin receptor antagonists, were more frequent in the atrasentan group than in the placebo group. Hospital admission for heart failure occurred in 47 (3·5%)of 1325 patients in the atrasentan group and 34 (2·6%)of 1323 patients in the placebo group (HR 1·33 [95% CI 0·85–2·07]; p=0·208). 58 (4·4%)patients in the atrasentan group and 52 (3·9%)in the placebo group died (HR 1·09 [95% CI 0·75–1·59]; p=0·65). Interpretation: Atrasentan reduced the risk of renal events in patients with diabetes and chronic kidney disease who were selected to optimise efficacy and safety. These data support a potential role for selective endothelin receptor antagonists in protecting renal function in patients with type 2 diabetes at high risk of developing end-stage kidney disease. Funding: AbbVie

    Role of three-dimensional transesophageal echocardiography in optimal device selection for percutaneous treatment of the ostium secundum atrial septal defect

    No full text
    INTRODUCAO: A comunicação interatrial tipo \"ostium secundum\" é um defeito cardíaco congênito caracterizado pela deficiência parcial ou total da lâmina da fossa oval, também chamada de septo primo. Corresponde a 10 a 12% do total de cardiopatias congênitas, sendo a mais frequente na idade adulta. Atualmente a oclusão percutânea é o método terapêutico de escolha em defeitos com características anatômicas favoráveis para o implante de próteses na maioria dos grandes centros mundiais. A ecocardiografia transesofágica bidimensional com mapeamento de fluxo em cores é considerada a ferramenta padrão-ouro para a avaliação anatômica e monitoração durante do procedimento, sendo crucial para a ótima seleção do dispositivo. Neste sentido, um balão medidor é introduzido e insuflado através do defeito de forma a ocluí-lo temporariamente. A medida da cintura que se visualiza no balão (diâmetro estirado) é utilizada como referência para a escolha do tamanho da prótese. Recentemente a ecocardiografia tridimensional transesofágica em tempo real tem sido utilizada neste tipo de intervenção percutânea. Neste estudo avaliamos o papel da mesma na ótima seleção do dispositivo levando-se em consideração as dimensões e a geometria do defeito e a espessura das bordas do septo interatrial. METODO: Estudo observacional, prospectivo, não randomizado, de único braço, de uma coorte de 33 pacientes adultos portadores de comunicação interatrial submetidos a fechamento percutâneo utilizando dispositivo de nitinol autocentrável (Cera ®, Lifetech Scientific, Shenzhen, China). Foram analisadas as medidas do maior e menor diâmetro do defeito, sua área e as medidas do diâmetro estirado com balão medidor obtidas por meio das duas modalidades ecocardiográficas. Os defeitos foram considerados como elípticos ou circulares segundo a sua geometria; as bordas ao redor da comunicação foram consideradas espessas (>2 mm) ou finas. O dispositivo selecionado foi igual ou ate 2 mm maior que o diâmetro estirado na ecocardiografia transesofágica bidimensional (padrão-ouro). Na tentativa de identificar uma variável que pudesse substituir o diâmetro estirado do balão para a ótima escolha do dispositivo uma série de correlações lineares foram realizadas. RESULTADOS: A idade e peso médio foram de 42,1 ± 14,9 anos e 66,0 ± 9,4kg, respectivamente; sendo 22 de sexo feminino. Não houve diferenças estatísticas entre os diâmetros maior e menor ou no diâmetro estirado dos defeitos determinados por ambas as modalidades ecocardiográficas. A correlação entre as medidas obtidas com ambos os métodos foi ótima (r > 0,90). O maior diâmetro do defeito, obtido à ecoardiografia transesofágica tridimensional, foi a variável com melhor correlação com o tamanho do dispositivo selecionado no grupo como um todo (r= 0,89) e, especialmente, nos subgrupos com geometria elíptica (r= 0,96) e com bordas espessas ao redor do defeito (r= 0,96). CONCLUSÃO: Neste estudo em adultos com comunicações interatriais tipo ostium secundum submetidos à oclusão percutânea com a prótese Cera ®, a ótima seleção do dispositivo pôde ser realizada utilizando-se apenas a maior medida do defeito obtida na ecocardiografia transesofágica tridimensional em tempo real, especialmente nos pacientes com defeitos elípticos e com bordas espessas.INTRODUCTION: The ostium secundum atrial septal defect is a congenital heart disease characterized by partial or total deficiency of the fossa ovalis, also known as the septum primum. It corresponds to 10-12% of all congenital heart defects, being the most frequently found in adulthood. Currently, percutaneous closure is the therapeutic method of choice for defects with suitable anatomic features for device implantation in most centers in the world. Bi-dimensional transesophageal echocardiography with color flow mapping is considered the gold-standard tool for anatomic assessment and procedural monitoring, being crucial for optimal device selection. In this regard, a sizing balloon is introduced and inflated across the defect with temporary occlusion. The waist measurement seen on the balloon (stretched diameter) is used as a reference for selection of device size. Recently, real time three-dimensional transesophageal echocardiography has been utilized in this type of percutaneous intervention. In this study we assessed the role of this modality in optimal device selection taking into consideration the dimensions and the geometry of the defect and the thickness of the interatrial septum rims. METHODS: Observational, prospective, non-randomized, single-arm study of a cohort of 33 adults with atrial septal defects submitted to percutaneous closure using a self-centered nitinol device (Cera (TM), Lifetech Scientific, Shenzhen, China). The largest and the smallest diameter of the defect, its area and the measurements of the stretched diameter of the sizing balloon were assessed by both echocardiographic modalities. The defects were considered as elliptical or circular according to their geometry; the rims surrounding the defect were considered thick (> 2 mm) or thin. The selected device was equal to or 2 mm larger than the stretched diameter on bi-dimensional transesophageal echocardiography (gold-standard). In an attempt to identify a variable that could replace the stretched balloon diameter, a series of linear correlations were performed. RESULTS: The mean age and weight were 42.1 ± 14.9 years and 66.0 ± 9.4 kgs, respectively; being 22 of the female gender. There were no statistical differences between the largest and smallest diameters of the defects and the stretched diameters determined by both echocardiographic modalities. The correlation between the measurements obtained by both methods was excellent (r > 0.90). The largest defect diameter obtained by three-dimensional transesophageal echocardiography was the variable that showed the best correlation with the selected device size in the entire group (r= 0.89), especially in the subgroups with elliptical geometry (r= 0.96) and with thick rims surrounding the defect (r=0.96). CONCLUSIONS: In this study in adults with ostium secundum atrial septal defects submitted to percutaneous occlusion with the Cera (TM) device, optimal device selection could be performed using solely the largest diameter of the defect obtained by real time three-dimensional transesophageal echocardiography, especially in patients with elliptical defects and thick rims
    corecore