7,127 research outputs found

    The Density Spike in Cosmic-Ray-Modified Shocks: Formation, Evolution, and Instability

    Get PDF
    We examine the formation and evolution of the density enhancement (density spike) that appears downstream of strong, cosmic-ray-modified shocks. This feature results from temporary overcompression of the flow by the combined cosmic-ray shock precursor/gas subshock. Formation of the density spike is expected whenever shock modification by cosmic-ray pressure increases strongly. That occurence may be anticipated for newly generated strong shocks or for cosmic-ray-modified shocks encountering a region of higher external density, for example. The predicted mass density within the spike increases with the shock Mach number and with shocks more dominated by cosmic-ray pressure. We find this spike to be linearly unstable under a modified Rayleigh-Taylor instability criterion at the early stage of its formation. We confirm this instability numerically using two independent codes based on the two-fluid model for cosmic-ray transport. These two-dimensional simulations show that the instability grows impulsively at early stages and then slows down as the gradients of total pressure and gas density decrease. Observational discovery of this unstable density spike behind shocks, possibly through radio emission enhanced by the amplified magnetic fields would provide evidence for the existence of strongly cosmic-ray modified shock structures.Comment: 26 pages in Latex and 6 figures. Accepted to Ap

    Enhanced Safety Surveillance of Influenza Vaccines in General Practice, Winter 2015-16: Feasibility Study

    Get PDF
    BACKGROUND: The European Medicines Agency (EMA) requires vaccine manufacturers to conduct enhanced real-time surveillance of seasonal influenza vaccination. The EMA has specified a list of adverse events of interest to be monitored. The EMA sets out 3 different ways to conduct such surveillance: (1) active surveillance, (2) enhanced passive surveillance, or (3) electronic health record data mining (EHR-DM). English general practice (GP) is a suitable setting to implement enhanced passive surveillance and EHR-DM. OBJECTIVE: This study aimed to test the feasibility of conducting enhanced passive surveillance in GP using the yellow card scheme (adverse events of interest reporting cards) to determine if it has any advantages over EHR-DM alone. METHODS: A total of 9 GPs in England participated, of which 3 tested the feasibility of enhanced passive surveillance and the other 6 EHR-DM alone. The 3 that tested EPS provided patients with yellow (adverse events) cards for patients to report any adverse events. Data were extracted from all 9 GPs' EHRs between weeks 35 and 49 (08/24/2015 to 12/06/2015), the main period of influenza vaccination. We conducted weekly analysis and end-of-study analyses. RESULTS: Our GPs were largely distributed across England with a registered population of 81,040. In the week 49 report, 15,863/81,040 people (19.57% of the registered practice population) were vaccinated. In the EPS practices, staff managed to hand out the cards to 61.25% (4150/6776) of the vaccinees, and of these cards, 1.98% (82/4150) were returned to the GP offices. Adverse events of interests were reported by 113 /7223 people (1.56%) in the enhanced passive surveillance practices, compared with 322/8640 people (3.73%) in the EHR-DM practices. CONCLUSIONS: Overall, we demonstrated that GPs EHR-DM was an appropriate method of enhanced surveillance. However, the use of yellow cards, in enhanced passive surveillance practices, did not enhance the collection of adverse events of interests as demonstrated in this study. Their return rate was poor, data entry from them was not straightforward, and there were issues with data reconciliation. We concluded that customized cards prespecifying the EMA's adverse events of interests, combined with EHR-DM, were needed to maximize data collection. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2016-015469

    Forest Management Guideline Development Through Consensus: Important Factors to Consider

    Get PDF
    Consensus forums are one method of dealing with controversial natural resource issues. Minnesota regulators learned numerous important lessons when they used a consensus-based approach to develop voluntary site-level forest management guidelines. These include: 1) take active steps to facilitate information sharing among team leaders, 2) select team members who can effectively represent their group's perspective, who are solution-oriented, and who can help shape a compromise, 3) be prepared for problems that will arise so that they don't bog down the process, 4) use field tours as a mechanism to educate participants and to test the practicality of proposed guidelines, and 5) build in flexibility to accommodate the range of considerations which affect guideline application

    Application of long period gratings sensors to respiratory function monitoring

    Get PDF
    A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber. An array of sensors is also used to reconstruct the shape changes of a resuscitation manikin during simulated respiration. The data for reconstruction is obtained by two methods of multiplexing and interrogation: firstly using the transmission spectral profile of the LPG's attenuation bands measured using an optical spectrum analyser; secondly using a derivative spectroscopy technique

    Ultrafast carrier dynamics on Si surfaces studied by femtosecond time-resolved two-photon photoelectron spectroscopy

    Full text link
    Secondary Ion Mass spectrometry (SIMS) has been generally used in the field of material sciences. In recent years, it has also been applied for molecular imaging of biological samples. Nevertheless, molecular ions derived from the large molecules (more than 1 kDa) were detected with very low sensitivity. Plasma desorption mass spectrometry (PDMS) is known as mass spectrometry for large organic molecule. In PDMS, fission fragments bombard samples and the impact induces molecular ionization by electronic excitation. Large organic molecules are detected by using swift heavy ions in SIMS. In this work, 6 MeV Cu4+ we irradiated angiotensin II, a class of peptides. The intact molecular ions generated by swift heavy ion irradiation were analyzed by time‐of‐flight (TOF) measurement. The yields are compared with some other probe ions, bismuth or flurane. Swift heavy ion bombardment ionized large organic molecules more effectively than other probes. Therefore, high energy ion can be applied in high resolution molecular imaging

    Laser frequency comb techniques for precise astronomical spectroscopy

    Full text link
    Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomical spectrographs, but here we show that they can also be used to measure IPS variations in astronomical CCDs in situ. We successfully tested a laser frequency comb system on the Ultra-High Resolution Facility spectrograph at the Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded in a single CCD exposure, we find that the average IPS deviates by <8 per cent if it is assumed to vary symmetrically about the pixel centre. We also demonstrate that series of comb exposures with absolutely known offsets between them can yield tighter constraints on symmetric IPS variations from ~100 pixels. We discuss measurement of asymmetric IPS variations and absolute wavelength calibration of astronomical spectrographs and CCDs using frequency combs.Comment: 11 pages, 7 figures. Accepted for publication in MNRA

    Extended-range fiber polarimetric strain sensor

    Get PDF
    We describe a frequency-modulation technique that is applicable to two-beam interferometric systems illuminated by semiconductor diode lasers. The technique permits a determination of the optical path difference between the two arms of the interferometer and is used here to extend the range of a fiber polarimetric strain sensor by determining the order of the particular polarimetric fringe under consideration
    corecore