6 research outputs found

    Stormwater quality and pollution loading from an urban residential catchment in Johor, Malaysia

    Get PDF
    Sampling of urban runoff was carried out in a small catchment, which represents a residential area (3.34 ha) in Skudai, Johor. One hundred and seventeen runoff samples from ten storm events were analysed. Runoff quality showed large variations in concentrations during storms, especially for SS, BOD5 and COD. Concentrations of NO3-N, NO2-N, NH3-N, and P were also high. Lead (Pb) was also detected but the levels were low (<0.001 mg/L). In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event mean concentrations for all parameters were found to vary greatly between storms. The values (mg/L) were BOD5 (72), COD (325), SS (386), NO3-N (2.5), NO2-N (0.58), NH3-N (6.8), P (3.4), respectively. First flush phenomena were observed for BOD, COD, SS, NO3-N, NH3-N and P. The first 20–30% of the runoff volume evacuated between 20–59% BOD, 15–69% COD, 15–78% SS, 14–49% NO3-N, 14–19% NO2-N, 23–53% NH3-N and 23–43% P

    Urban stormwater quality and load estimation from urban residential area in Skudai, Johor

    No full text
    Sampling of urban runoff was carried out in a small catchment, which represents a residential area (3.34 ha) in Skudai, Johor. One hundred and seventeen runoff samples from ten storm events were analysed. Runoff quality showed large variations in concentrations during storms, especially for SS, BOD5 and COD. Concentrations of NO3-N, NO2-N, NH3-N, and P were also high. Lead (Pb) was also detected but the levels were low (<0.001 mg/L). In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event mean concentrations for all parameters were found to vary greatly between storms. The values (mg/L) were BOD5 (72), COD (325), SS (386), NO3-N (2.5), NO2-N (0.58), NH3-N (6.8), P (3.4), respectively. First flush phenomena were observed for BOD, COD, SS, NO3-N, NH3-N and P. The first 20-30% of the runoff volume evacuated between 20-59% BOD, 15-69% COD, 15-78% SS, 14-49% NO3-N, 14-19% NO2-N, 23-53% NH3-N and 23-43% P

    Modelling runoff quantity and quality in tropical urban catchments using storm water management model

    Get PDF
    Due to differences in rainfall regimes and management practices, tropical urban catchments are expected to behave differently from temperate catchments in terms of pollutant sources and their transport mechanism. Storm Water Management Model (SWMM) was applied to simulate runoff quantity (peakflow and runoff depth) and quality (total suspended solids and total phosphorous) in residential, commercial and industrial catchments. For each catchment, the model was calibrated using 8-10 storm events and validated using seven new events. The model performance was evaluated based on the relative error, normalized objective function, Nash-Sutcliffe coefficient and 1:1 plots between the simulated and observed values. The calibration and validation results showed good agreement between simulated and measured data. Application of Storm Water Management Model for predicting runoff quantity has been improved by taking into account catchment's antecedent moisture condition. The impervious depression storages obtained for dry and wet conditions were 0. 8 and 0. 2 mm, respectively. The locally derived build-up and wash-off parameters were used for modelling runoff quality
    corecore