6,709 research outputs found

    The return of an English pluperfect subjunctive?

    Get PDF
    The introduction of the superfluous morpheme [әv] into past unfulfilled if-clauses in modern English raises serious questions of analysis. How is one to parse a clause like: “If I had’ve known that...”? It is proposed that the intrusive morpheme can be viewed as a marker of subjunctivity, whereby “real” and “unreal” pluperfects can be explicitly distinguished

    An application of eigenspace methods to symmetric flutter suppression

    Get PDF
    An eigenspace assignment approach to the design of parameter insensitive control laws for linear multivariable systems is presented. The control design scheme utilizes flexibility in eigenvector assignments to reduce control system sensitivity to changes in system parameters. The methods involve use of the singular value decomposition to provide an exact description of allowable eigenvectors in terms of a minimum number of design parameters. In a design example, the methods are applied to the problem of symmetric flutter suppression in an aeroelastic vehicle. In this example the flutter mode is sensitive to changes in dynamic pressure and eigenspace methods are used to enhance the performance of a stabilizing minimum energy/linear quadratic regulator controller and associated observer. Results indicate that the methods provide feedback control laws that make stability of the nominal closed loop systems insensitive to changes in dynamic pressure

    Reactivation of Limestone-Derived Sorbents using Hydration: Preliminary Results From a Fluidised Bed

    Get PDF
    A simple method of CO~2~ capture is by using the calcium looping cycle. The calcium looping cycle uses CaCO~3~ as a CO~2~ carrier, via the reversible reaction CaO(s) + CO~2~(g) = CaCO~3~(s), to extract CO2 from the exhaust stream and provide a pure stream of CO~2~ suitable for sequestration. 
A problem associated with the technology is that the capacity of the sorbent to absorb CO~2~ reduces significantly with the number of cycles of carbonation and calcination. The energy penalty of the cycle is considerably increased by cycling unreacted sorbent: hydration of unreactive sorbent has emerged as a promising strategy of reducing this penalty by regenerating the reactivity of exhausted sorbent.
A small atmospheric pressure fluidised bed reactor has been built and tested, that allows repeated cycling between two temperatures up to 1000 °C. 
Work presented here focuses on the effects of variation of the calcination temperature before hydration. Hydration has been found to more than double the reactivity of a spent sorbent cycled under the mildest conditions studied (calcination temperature of 840 °C). However, as calcination temperature is increased the observed reactivation decreases until little reactivation is observed for the sorbent cycled at 950 °C. The primary reason for this appears to be a substantial increase in friability of particles, with reactivity normalised for mass losses appearing similar independent of cycling temperature

    Carbon capture in the cement industry: technologies, progress, and retrofitting

    Get PDF
    Several different carbon-capture technologies have been proposed for use in the cement industry. This paper reviews their attributes, the progress that has been made toward their commercialization, and the major challenges facing their retrofitting to existing cement plants. A technology readiness level (TRL) scale for carbon capture in the cement industry is developed. For application at cement plants, partial oxy-fuel combustion, amine scrubbing, and calcium looping are the most developed (TRL 6 being the pilot system demonstrated in relevant environment), followed by direct capture (TRL 4–5 being the component and system validation at lab-scale in a relevant environment) and full oxy-fuel combustion (TRL 4 being the component and system validation at lab-scale in a lab environment). Our review suggests that advancing to TRL 7 (demonstration in plant environment) seems to be a challenge for the industry, representing a major step up from TRL 6. The important attributes that a cement plant must have to be “carbon-capture ready” for each capture technology selection is evaluated. Common requirements are space around the preheater and precalciner section, access to CO2 transport infrastructure, and a retrofittable preheater tower. Evidence from the electricity generation sector suggests that carbon capture readiness is not always cost-effective. The similar durations of cement-plant renovation and capture-plant construction suggests that synchronizing these two actions may save considerable time and money

    Definition of Throw-Away Detectors (TADs) and VLF antenna for the AMPS laboratory

    Get PDF
    A Throw Away Detector (TAD)/subsatellite to be used as an experiment platform for the test flights to map the EMI from the shuttle and during the AMPS science flights is defined. A range of instrument platforms of varying capabilities is examined with emphasis on the EMI test vehicle. The operational support requirements of TAD/subsatellites are determined. The throw away detector is envisioned as a simple instrument package for supporting specific experiments
    • …
    corecore