101 research outputs found

    Controlled Synthesis of Titania using Water-soluble Titanium Complexes: A Review

    Get PDF
    The development of human society has led to the increase in energy and resources consumption as well as the arising problems of environmental damage and the toxicity to the human health. The development of novel synthesis method which tolerates utilization of toxic solvents and chemicals would fulfill the demand of the society for safer, softer, and environmental friendly technologies. For the past decades, a remarkable progress has been attained in the development of new water-soluble titanium complexes (WSTC) and their use for the synthesis of nanocrystalline titanium dioxide materials by aqueous solution-based approaches. The progress of synthesis of nanocrystalline titanium dioxide using such WSTCs is reviewed in this work. The key structural features responsible for the successfully controlled synthesis of TiO2 are discussed to provide guidelines for the morphology-controlled synthesis. Finally, this review ends with a summary and some perspectives on the challenges as well as new directions in this fascinating research

    Extraction of anthocyanins from Butterfly pea (Clitoria ternatea L. Flowers) in Southern Vietnam: Response surface modeling for optimization of the operation conditions

    Get PDF
    In this paper, the Response Surface Methodology (RSM), in conjunction with Central Composite Design (CCD), was used to optimize the extraction of anthocyanins from Butterfly pea (Clitoria ternatea L.Flowers) cultivated in Southern Vietnam. The effect of extraction temperatures of solvent ethanol (50-70 °C), duration of extraction (40-50 min) and solid-liquid ratios (20:1-30:1) was measured as independent variables on the total extraction anthocyanins in the response function. The highest anthocyanin content of 132.756 mg/L of butterfly pea anthocyanin was collected at the solid liquid ratio of 23:1, extraction time of 46 min, and temperature 60.6°C. Butterfly pea anthocyanins yield detailed significant correlation with high F values, low P values (<0.0001), and desirable determination coefficient (R2 = 0.9994)

    Protective and Enhancing HLA Alleles, HLA-DRB1*0901 and HLA-A*24, for Severe Forms of Dengue Virus Infection, Dengue Hemorrhagic Fever and Dengue Shock Syndrome

    Get PDF
    Dengue has become one of the most common viral diseases transmitted by infected mosquitoes (with any of the four dengue virus serotypes: DEN-1, -2, -3, or -4). It may present as asymptomatic or illness, ranging from mild to severe disease. Recently, the severe forms, dengue hemorrhagic fever (DHF) and dengue shock syndrome (DSS), have become the leading cause of death among children in Southern Vietnam. The pathogenesis of DHF/DSS, however, is not yet completely understood. The immune response, virus virulence, and host genetic background are considered to be risk factors contributing to disease severity. Human leucocyte antigens (HLA) expressed on the cell surface function as antigen presenting molecules and those polymorphism can change individuals' immune response. We investigated the HLA-A, -B (class I), and -DRB1 (class II) polymorphism in Vietnamese children with different severity (DHF/DSS) by a hospital-based case-control study. The study showed persons carrying HLA-A*2402/03/10 are about 2 times more likely to have severe dengue infection than others. On the other hand, HLA-DRB1*0901 persons are less likely to develop DSS with DEN-2 virus infection. These results clearly demonstrated that HLA controlled the susceptibility to severe forms of DV infection

    Anisotropy studies around the galactic centre at EeV energies with the Auger Observatory

    Get PDF
    Data from the Pierre Auger Observatory are analyzed to search for anisotropies near the direction of the Galactic Centre at EeV energies. The exposure of the surface array in this part of the sky is already significantly larger than that of the fore-runner experiments. Our results do not support previous findings of localized excesses in the AGASA and SUGAR data. We set an upper bound on a point-like flux of cosmic rays arriving from the Galactic Centre which excludes several scenarios predicting sources of EeV neutrons from Sagittarius AA. Also the events detected simultaneously by the surface and fluorescence detectors (the `hybrid' data set), which have better pointing accuracy but are less numerous than those of the surface array alone, do not show any significant localized excess from this direction.Comment: Matches published versio

    СПЕКТРЫ DLTS КРЕМНИЕВЫХ ДИОДОВ С p+—n–ПЕРЕХОДОМ, ОБЛУЧЕННЫХ ВЫСОКОЭНЕРГЕТИЧЕСКИМИ ИОНАМИ КРИПТОНА

    Get PDF
    p+-n-Diodes have been studied. The diodes were manufactured on wafers (thickness 460 μm, (111) plane) of uniformly phosphorus doped float–zone–grown single–crystal silicon. The resistivity of silicon was 90 Ohm · cm and the phosphorus concentration was 5 · 1013 cm–3. The diodes were irradiated with 250 MeV krypton ions. The irradiation fluence was 108 cm–2. Deep–level transient spectroscopy (DLTS) was used to examine the defects induced by high energy krypton ion implantation. The DLTS spectra were recorded at a frequency of 1 MHz in the 78—290 K temperature range. The capacity–voltage characteristics have been measured at a reverse bias voltage from 0 to –19 V at a frequency of 1 MHz. We show that the main irradiation–induced defects are A–centers and divacancies. The behavior of DLTS spectra in the 150—260 K temperature range depends essentially on the emission voltage Ue. The variation of Ue allows us to separate the contributions of different defects into the DLTS spectrum in the 150—260 K temperature range. We show that, in addition to A–centers and divacancies, irradiation produces multivacancy complexes with the energy level Et = Ec – (0.5 ± 0.02) eV and an electron capture cross section of ~4 · 10–13 cm2.Исследованы p+—n-диоды. Диоды изготовлены на пластинах однородно легированного фосфором монокристаллического кремния (толщина 460 мкм, плоскость (111)), выращенного методом бестигельной зонной плавки. Удельное сопротивление кремния — 90 Ом × см, концентрация фосфора — 5 × 1013 см−3. Диоды подвергнуты облучению ионами криптона с энергией 250 МэВ. Флюенс облучения — 108 см−2. Радиационные дефекты, вводимые высокоэнергетической имплантацией ионов криптона, исследованы с помощью нестационарной спектроскопии глубоких уровней (DLTS — Deep−level transient spectroscopy). Спектры DLTS регистрировали на частоте 1 МГц в интервале температур 78—290 К. Вольт-фарадные характеристики измерены при напряжении обратного смещения от 0 до – 19 В на частоте 1 МГц. Показано, что основными радиационными дефектами являются А−центры и дивакансии. Установлено, что вид спектров DLTS в интервале температур 150—260 K существенно зависит от напряжения эмиссии Ue. Варьирование Ue в ходе эксперимента позволило разделить вклады от различных дефектов в спектр DLTS в интервале температур 150—260 К. Показано, что, помимо А−центров и дивакансий, при облучении формируются многовакансионные комплексы с энергетическим уровнем Et = Ec -(0,50 ± 0,02) эВ и сечением захвата электронов ~ 4 × 10−13 см2

    Viral Etiology of Encephalitis in Children in Southern Vietnam: Results of a One-Year Prospective Descriptive Study

    Get PDF
    Viral encephalitis is associated with high morbidity and mortality in Vietnam. However little is known about the causes of the disease due to a lack of diagnostic facilities in this relatively resource-poor setting. Knowledge about the etiologies and clinical outcome of viral encephalitis is necessary for future design of intervention studies targeted at improvement of clinical management, treatment and prevention of the disease. We report the viral agents, clinical outcome and prognostic factors of mortality of encephalitis in children admitted to a referral hospital for children in southern Vietnam. We show that about one third of the enrolled patients die acutely, and that mortality is independently associated with patient age and Glasgow Coma Scale on admission. Japanese encephalitis, dengue virus and enterovirus (including enterovirus 71) are the major viruses detected in our patients. However, more than half of the patients remain undiagnosed, while mortality in this group is as high as in the diagnosed group. This study will benefit clinicians and public health in terms of clinical management and prevention of childhood encephalitis in Vietnam

    An upper limit to the photon fraction in cosmic rays above 10^19 eV from the Pierre Auger Observatory

    Get PDF
    An upper limit of 16% (at 95% c.l.) is derived for the photon fraction in cosmic rays with energies above 10^19 eV, based on observations of the depth of shower maximum performed with the hybrid detector of the Pierre Auger Observatory. This is the first such limit on photons obtained by observing the fluorescence light profile of air showers. This upper limit confirms and improves on previous results from the Haverah Park and AGASA surface arrays. Additional data recorded with the Auger surface detectors for a subset of the event sample, support the conclusion that a photon origin of the observed events is not favoured
    corecore