21 research outputs found

    Ocorrência e relatos de casos de fraturas radiculares do Projeto Centro Especializado Maringaense de Traumatismo em Odontologia da Universidade Estadual de Maringá

    Get PDF
    Objective:Objetivo: verificar a ocorrência de fraturas horizontais radiculares traumáticas em pacientes do projeto de extensão Centro Especializado Maringaense de Traumatismo em Odontologia da Universidade Estadual de Maringá (CEMTrau-Odonto), assim como avaliar os procedimentos realizados e relatar casos clínicos. Material e Métodos: foram avaliados 267 prontuários dos pacientes deste projeto correspondentes ao período de 2002 a 2006, quanto às imagens radiográficas, à história e ao diagnóstico do trauma e à conduta terapêutica. Resultados: dentre as conseqüências dos traumatismos dentoalveolares no projeto CEMTrau-Odonto a fratura radicular horizontal correspondeu a 3% e o tratamento endodôntico foi realizado em quatro dos nove casos acometidos por esta injúria. Conclusão: embora a fratura radicular horizontal tenha apresentado ocorrência relativamente baixa (3%), não se pode negligenciá-las. Os casos apresentados mostraram a importância de uma equipe multidisciplinar realizando procedimentos clínicos e métodos de acompanhamento coerentes com a literatura

    TRAUMATISMO DO DENTE DECÍDUO RESULTANDO EM SEQÜELAS NO DENTE PERMANENTE – RELATO DE CASO

    Get PDF
    O traumatismo dentário, na época da dentição decídua, constitui um problema freqüente, sendo incisivo central o mais acometido. Alterações na morfologia ou mineralização da coroa do incisivo permanente são os tipos mais comuns de complicações, podendo variar de pequenas opacidades de esmalte a graves malformações. O presente trabalho se propõe a relatar o caso clínico  de uma criança, com presença de erupção ectópica e dilaceração da coroa no dente 11, e hipoplasia de esmalte no 11 e 12. Foi relatado na anamnese um  traumatismo dentário ocorrido aos 4 anos de idade, devido a um coice de um cavalo, ocorrendo a luxação do 61, e a avulsão do dente 51. Após de realizado o tratamento de emergência perdeu-se o contato com profissional. Aos 7 anos o paciente retornou ao consultório queixando-se da ausência do dente 11, diagnosticando-se retenção prolongada, indicativo de tracionamento. No entanto, o abandono às consultas de retorno inviabilizou o tratamento. Decorridos 3 anos  foi instalado um aparelho ortopédico para  o tracionamento correto, para em seguida ser realizado o tratamento restaurador estético. Concluiu-se, portanto, que os controles clínicos e radiográficos freqüentes, aliados ao envolvimento da família, são fatores decisivos no tratamento de seqüelas pós-traumáticas em crianças

    LEVANTAMENTO DOS CASOS DE AVULSÃO DENTÁRIA DO CENTRO ESPECIALIZADO MARINGAENSE DE TRAUMATISMO ODONTOLÓGICO

    Get PDF
    As lesões traumáticas dentárias se caracterizam como um dos mais sérios problemas de saúde bucal entre crianças e adolescentes e representam uma das causas mais comuns de procura dos serviços de pronto-atendimento. A avulsão dentária se caracteriza pelo completo deslocamento do dente de seu alvéolo, e o melhor prognóstico está diretamente relacionado ao tempo extra-alveolar antes do reimplante e com as condições sob as quais o dente foi armazenado. O objetivo deste trabalho foi analisar, através de prontuários odontológicos, os casos de avulsões dentárias que compareceram ao Centro Especializado Maringaense de Traumatismo Odontológico (CEMTrau-Odonto) da Universidade Estadual de Maringá. A pesquisa foi realizada através da análise de 50 prontuários odontológicos dos casos de avulsões dentárias do Projeto CEMTrau-Odonto. Os pacientes possuíam idade entre 2 e 44 anos sendo que 34% se concentrava entre 2 e 9 anos e 19% dos casos foram causados por quedas de bicicleta. O reimplante foi realizado em 56% dos casos e 37% dos dentes foram mantidos a seco por mais de 30 minutos. Sabendo-se disso, os profissionais devem estar preparados para receber pacientes com história de traumatismos, sejam eles mais simples como uma fratura de esmalte, ou até mais complexos, como a avulsão

    Report from Working Group 3: Beyond the standard model physics at the HL-LHC and HE-LHC

    Get PDF
    This is the third out of five chapters of the final report [1] of the Workshop on Physics at HL-LHC, and perspectives on HE-LHC [2]. It is devoted to the study of the potential, in the search for Beyond the Standard Model (BSM) physics, of the High Luminosity (HL) phase of the LHC, defined as 33 ab1^{-1} of data taken at a centre-of-mass energy of 14 TeV, and of a possible future upgrade, the High Energy (HE) LHC, defined as 1515 ab1^{-1} of data at a centre-of-mass energy of 27 TeV. We consider a large variety of new physics models, both in a simplified model fashion and in a more model-dependent one. A long list of contributions from the theory and experimental (ATLAS, CMS, LHCb) communities have been collected and merged together to give a complete, wide, and consistent view of future prospects for BSM physics at the considered colliders. On top of the usual standard candles, such as supersymmetric simplified models and resonances, considered for the evaluation of future collider potentials, this report contains results on dark matter and dark sectors, long lived particles, leptoquarks, sterile neutrinos, axion-like particles, heavy scalars, vector-like quarks, and more. Particular attention is placed, especially in the study of the HL-LHC prospects, to the detector upgrades, the assessment of the future systematic uncertainties, and new experimental techniques. The general conclusion is that the HL-LHC, on top of allowing to extend the present LHC mass and coupling reach by 2050%20-50\% on most new physics scenarios, will also be able to constrain, and potentially discover, new physics that is presently unconstrained. Moreover, compared to the HL-LHC, the reach in most observables will, generally more than double at the HE-LHC, which may represent a good candidate future facility for a final test of TeV-scale new physics

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Clinical Approach to External Cervical Resorption in the Anterior Teeth: A Case Report Study: Management of external cervical resorption

    No full text
    External cervical resorption (ECR) is a pathology that is difficult to diagnose early, and because it is often confused with root decay, it can be treated inadequately and even result in tooth loss. Currently, treatment does not have a defined protocol, being widely varied in the literature. This article proposes that cases of ECR should be treated individually, following different criteria, based on aspects related to the patient and the tooth involved. Furthermore, this work illustrates, through a case report, how a patient can present unique characteristics that require treatment to be case-dependent and should be discussed among a multidisciplinary team

    Evidentiation of Paramyosin (Sm-97) as a Modulating Antigen on Granulomatous Hypersensitivity to Schistosoma mansoni Eggs

    No full text
    A Schistosoma mansoni adult worm anionic fraction (PIII) has previously been shown to protect mice against challenge infection and to reduce pulmonary and hepatic granulomatous hypersensitivity. Serum from PIII-immunized rabbit was used to screen a lgt11 cDNA library from S. mansoni adult worm in order to identify antigens capable of modulating granulomatous hypersensitivity. We obtained four clones with 400 (Sm-III.11), 900 (Sm-III.16), 1100 (Sm-III.10) and 1300 (Sm-III.12) bp of length. All clone-specific antibodies were able to recognize most of the PIII components. The sequence analysis showed that these clones presented high homology with S. mansoni paramyosin (Sm-97). These findings ascribe a new function to this antigen with an important role in modulation of granulomatous hypersensitivity to S. mansoni egg

    Avaliação in vitro da influência da lima patência na manutenção do comprimento de trabalho

    No full text
    Resumo Objetivo Este trabalho teve como objetivo avaliar a influência da lima patência na manutenção do comprimento de trabalho (CT) durante o preparo coroa-ápice, utilizando o sistema oscilatório em canais artificiais de acrílico. Material e método Foram utilizados 30 cubos de acrílico: a) grupo 1 (n=10): sem a lima patência e preparo no CT (CT=16 mm); b) grupo 2 (n=10): com a lima patência K#10, comprimento de patência de 17 mm e preparo no CT; c) grupo 3 (n=10): sem a lima patência, uso de uma lima K#10 em 16 mm para recapitulação e preparo no CT. Água destilada foi utilizada como solução irrigadora. O resultado foi analisado estatisticamente pelos testes de Levene e Kruskal-Wallis (p≤0,05), pelos quais se tornou possível observar a perda do comprimento de trabalho após a instrumentação, em diferentes abordagens, em relação à lima patência. Resultado Os resultados obtidos demonstraram que houve diferença estatisticamente significante entre os grupos 1 e 3 quando comparados ao grupo 2; entretanto, ao comparar-se o grupo 1 com o grupo 3, estes apresentaram semelhanças estatísticas. O grupo 2 foi o único que conservou o CT após a instrumentação em 16 mm, enquanto os grupos 1 e 3 apresentaram uma perda de até 2 mm do CT. Conclusão Conclui-se que a lima patência em 1 mm além do CT mostrou-se eficaz na manutenção do seu comprimento durante o preparo do canal radicular

    Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    No full text
    Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS), four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR) in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360) were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC) curve (Az) were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively). The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631). Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve
    corecore