323 research outputs found

    Des appareillages en évolution : détection haute résolution en position et en temps

    No full text
    École thĂ©matiqu

    MPGD's spatial and energy resolution studies with an adjustable point-like electron source

    No full text
    11th Vienna Conference on Instrumentation (February 2007) , to appear in the Proceedings (NIM A)International audienceMicropattern Gaseous Detectors (MPGD), like Micromegas or GEM, are used or foreseen in particle physics experiments for which a very good spatial resolution is required. We have developed an experimental method to separate the contribution of the transverse diffusion and the multiplication process by varying the number of primary electrons generated by a point-like source. A pulsed nitrogen laser is focused by an optical set-up on the drift electrode which is made of a thin metal layer deposited on a quartz lamina. The number of primary electrons can be adjusted from a few to several thousands on a spot which transverse size is less than 100ÎŒm100 \mu m RMS. The detector can be positioned with an accuracy of 1ÎŒm1\mu m by a motorized three dimensional system. This method was applied to a small Micromegas detector with a gain set between 10310^3 and 2.1042.10^4 and an injection of 60 to 2000 photoelectrons. Spatial resolutions as small as 5ÎŒm5\mu m were measured with 2000 primary electrons. An estimation of the upper limit of the relative gain variance can be obtained from the measurements

    A large dynamic range integrated front-end for photomultiplier tubes

    No full text
    A full custom analog CMOS circuit for obtaining a photomultiplier readout with a 16 bit resolution over 7 V has been developed. It is part of the R&D program for the photomultiplier tube front-end readout of the Pierre Auger Observatory northern site. It performs signal duplication and amplification with three gains: 0.15, 1 and 6. Each amplifier has a resolution of 10 bit and can measure signals with durations of several microseconds with a good baseline stability, for an input charge of up to tens of nano-Coulombs. The amplification is performed by current feedback amplifiers with a bandwidth of 60 MHz.The input impedance, adapted to the coaxial cables, is stable over the whole working range. A prototype was submitted in April 2004 and successfully tested. The linearity over the working range is less than 1%. It was also successfully tested on the Auger surface detector element installed at Orsay (comprised of a Cherenkov water tank equipped with Photonis XP1805 9” diameter photomultiplier tubes). The resolution over 7 V is 16.6 bit.This circuit is the first step towards a “system-on-a-chip” (SoC) solution for a photomultplier tube readout equipped with a fast ADC for signal digitization. A setup using a single cable for both the signal and the photomultiplier high voltage power supply was shown to be successful

    SD electronics: simulations on the dynamic range

    Get PDF
    The surface detector electronics of the Pierre Auger Observatory is characterized by a large dynamic range due to the variation of the signal intensity of the Cherenkov tanks as a function of the distance from the core. In this paper, we present results of simulations and discuss the impact of the dynamic range on the shower reconstruction

    Design of the photomultiplier bases for the surface detectors of the Pierre Auger Observatory

    Get PDF
    The design of the photomultiplier bases for the surface detectors of the Pierre Auger Observatory is presented. The bleeder is purely resistive. The base comprises two outputs: one from the anode and another one from the last dynode followed by an amplifier. The charge ratio between the anode and the amplified dynode is around 30. The design ensures a low consumption (less than 100 mu A at 2 kV), a stability of the gain and of the base line during the whole period of measurement (20 mu s per event) and for the whole dynamic range (max. 1 to 3x10^4 in amplitude). First measurement with a prototype base on the Hamamatsu R5912 photomultiplier tube are presented

    Liquid-gas phase transition in hot nuclei studied with INDRA

    Full text link
    Thanks to the high detection quality of the INDRA array, signatures related to the dynamics (spinodal decomposition) and thermodynamics (negative microcanonical heat capacity) of a liquid-gas phase transition have been simultaneously studied in multifragmentation events in the Fermi energy domain. The correlation between both types of signals strongly supports the existence of a first order phase transition for hot nuclei.Comment: 9 pages, 2 figures, Invited talk to Nucleus-nucleus 2003 Moscow June 200

    Freeze-out volume in multifragmentation - dynamical simulations

    Get PDF
    Stochastic mean-field simulations for multifragmenting sources at the same excitation energy per nucleon have been performed. The freeze-out volume, a concept which needs to be precisely defined in this dynamical approach, was shown to increase as a function of three parameters: freeze-out instant, fragment multiplicity and system size.Comment: Submitted to Eur. Phys. J. A - march 200

    Fragment properties of fragmenting heavy nuclei produced in central and semi-peripheral collisions

    Get PDF
    Fragment properties of hot fragmenting sources of similar sizes produced in central and semi-peripheral collisions are compared in the excitation energy range 5-10 AMeV. For semi-peripheral collisions a method for selecting compact quasi-projectiles sources in velocity space similar to those of fused systems (central collisions) is proposed. The two major results are related to collective energy. The weak radial collective energy observed for quasi-projectile sources is shown to originate from thermal pressure only. The larger fragment multiplicity observed for fused systems and their more symmetric fragmentation are related to the extra radial collective energy due to expansion following a compression phase during central collisions. A first attempt to locate where the different sources break in the phase diagram is proposed.Comment: 23 pages submitted to NP

    The HADES Tracking System

    Full text link
    The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in total about 30 square meter of active area. Low multiple scattering in the in total four planes of drift chambers before and after the magnetic field is ensured by using helium-based gas mixtures and aluminum cathode and field wires. First in-beam performance results are contrasted with expectations from simulations. Emphasis is placed on the energy loss information, exploring its relevance regarding track recognition.Comment: 6 pages, 4 figures, presented at the 10th Vienna Conference on Instrumentation, Vienna, February 2004, to be published in NIM A (special issue

    Measurements of sideward flow around the balance energy

    Full text link
    Sideward flow values have been determined with the INDRA multidetector for Ar+Ni, Ni+Ni and Xe+Sn systems studied at GANIL in the 30 to 100 A.MeV incident energy range. The balance energies found for Ar+Ni and Ni+Ni systems are in agreement with previous experimental results and theoretical calculations. Negative sideward flow values have been measured. The possible origins of such negative values are discussed. They could result from a more important contribution of evaporated particles with respect to the contribution of promptly emitted particles at mid-rapidity. But effects induced by the methods used to reconstruct the reaction plane cannot be totally excluded. Complete tests of these methods are presented and the origins of the ``auto-correlation'' effect have been traced back. For heavy fragments, the observed negative flow values seem to be mainly due to the reaction plane reconstruction methods. For light charged particles, these negative values could result from the dynamics of the collisions and from the reaction plane reconstruction methods as well. These effects have to be taken into account when comparisons with theoretical calculations are done.Comment: 27 pages, 15 figure
    • 

    corecore