304 research outputs found

    Optimisation de la technique de dissection sous muqueuse à l’aide d’un bistouri à jet d’eau haute-pression pulsée pour le traitement endoscopique des tumeurs superficielles du tube digestif

    Get PDF
    First of all, we worked on the training for unexperienced operators by developing a bovine colon model more adapted to the European situation where colo-rectal lesions are the most common. This model of rectum from bovine, easy to find and to prepare allows training in conditions most close to the human colonic wall than those offered by the pig stomach. Furthermore, such models allows to teach the initial skills but avoiding the risk of adverse events for the first procedures in humans. A future work evaluating the benefits of a learning support by a dedicated interactive software on this model with 37 french and Japanese students is now being analyzed and will be reported soon. Then we thought about the strategy of the procedure in order to make it more simple using the tunnel technique to perform ESD for the esophageal lesions. This strategy helps to maintain traction on the edges and offers a sort of triangulation physically expanding the working space. This strategy has become a standard for esophageal resections in many teams and we still work to improve its efficacy. Finally, we worked jointly with Nestis® Company to develop a tool to optimize the submucosal dissection procedure by combining the benefits of the catheters bi function (injecting and cutting with the same tool), but adding high pulsed pressure and capability to inject viscous macromolecular solutions. The Nestis® system allows for the first time this association and demonstrated his interest in terms of security and performance compared with the conventional method using the needle and a conventional electrocautery device. With this bi function tool, it is not necessary to change instrument frequently since all stages of the procedure are now done with a single device. Other projects are already included with this material to explore its benefits and its safety in human colonic dissection that is deemed as the most difficult due to the thinner wall. Finally, this material offers the possibility to inject pressurized active drugs which could be used in the future to prevent the occurrence of esophageal strictures or to direct healing. We also worked with the hospital Edouard Herriot pharmacy to stabilize the solution glycerol mix to allow its use in daily practice in our unitDans cette thèse, nous avons travaillé sur les différents versants de la technique de dissection sous-muqueuse et les problèmes que pose ce geste quasi chirurgical dans des unités d'endoscopie initialement médicales. Tout d'abord, nous avons travaillé sur la formation à la technique en développant un modèle d'apprentissage sur colon de bovin plus adapté à la situation européenne où les lésions colo-rectales sont les plus fréquentes. Ce modèle de rectum de bovin, simple à trouver et à préparer permet une formation dans des conditions plus proches de la paroi colique humaine que celles offertes par l'estomac de cochon. Un travail à plus grande échelle évaluant les bénéfices d'une aide à l'apprentissage par un logiciel interactif dédié mené sur ce modèle avec 37 étudiants français et japonais est en cours d'analyse et sera publié prochainement. Ensuite, nous avons réfléchi à la stratégie de la procédure pour la rendre plus simple en évaluant précocement la technique du tunnel pour la dissection des lésions œsophagiennes. Cette stratégie permet de maintenir une traction sur les bords lésionnels et nous offrent une sorte de triangulation en élargissant physiquement la zone de travail. Cette stratégie est devenue un standard pour les résections œsophagiennes dans de nombreuses équipes. Enfin, nous avons travaillé conjointement avec la société Nestis® au développement d'un outil permettant d'optimiser la procédure de dissection sous-muqueuse en associant les bénéfices des bistouris bi fonction (injectant et coupant avec le même outil}, de la haute pression pulsée et des solutions macromoléculaires visqueuses. Le système Nestis® permet pour la première fois cette association et a démontré son intérêt en termes de sécurité et de performance par rapport à la méthode classique utilisant l'aiguille et un bistouri électrique conventionnel. Avec cet outil bi fonction, il n'est plus nécessaire de changer d'instrument puisque toutes les étapes de la procédure sont désormais réalisées avec un seul et même outil. D'autres projets sont déjà prévus avec ce matériel pour étudier ses bénéfices et sa sécurité en dissection colique humaine qui est réputée comme la plus difficile compte tenu de la finesse de la paroi. Enfin, ce matériel offre la possibilité d'injecter sous pression des principes actifs qui pourrait dans le futur permettre de prévenir la survenue de sténoses œsophagiennes ou diriger la cicatrisation. Nous avons ainsi travailler avec la pharmacie de l'hôpital Edouard Herriot pour stabiliser la solution macromoléculaires de mélange de glycérol pour permettre son utilisation en pratique quotidienn

    Optimising the performance and interpretation of small bowel capsule endoscopy

    Get PDF
    Small bowel capsule endoscopy has become a commonly used tool in the investigation of gastrointestinal symptoms and is now widely available in clinical practice. In contrast to conventional endoscopy, there is a lack of clear consensus on when competency is achieved or the way in which capsule endoscopy should be performed in order to maintain quality and clinical accuracy. Here we explore the evidence on the key factors that influence the quality of small bowel capsule endoscopy services

    The treatment of achalasia patients with esophageal varices: an international study

    Get PDF
    Background: Treatment options for achalasia include endoscopic and surgical techniques that carry the risk of esophageal bleeding and perforation. The rare coexistence of esophageal varices has only been anecdotally described and treatment is presumed to carry additional risk. Methods: Experience from physicians/surgeons treating this rare combination of disorders was sought through the International Manometry Working Group. Results: Fourteen patients with achalasia and varices from seven international centers were collected (mean age 61 9 years). Five patients were treated with botulinum toxin injections (BTI), four had dilation, three received peroral endoscopic myotomy (POEM), one had POEM then dilation, and one patient underwent BTI followed by Heller’s myotomy. Variceal eradication preceded achalasia treatment in three patients. All patients experienced a significant symptomatic improvement (median Eckardt score 7 vs 1; p < 0.0001) at 6 months follow-up, with treatment outcomes resembling those of 20 non- cirrhotic achalasia patients who underwent similar therapy. No patients had recorded complications of bleeding or perforation. Conclusion: This study shows an excellent short-term symptomatic response in patients with esophageal achalasia and varices and demonstrates that the therapeutic outcomes and complications, other than transient encephalopathy in both patients who had a portosystemic shunt, did not differ to disease-matched patients without varices

    The Autophagic Flux Inhibitor Bafilomycine A1 Affects the Expression of Intermediary Metabolism-Related Genes in Trout Hepatocytes

    Get PDF
    Autophagy is an evolutionarily conserved process of cellular self-eating which emerged these last years as a major adaptive metabolic response to various stresses such as fasting, hypoxia, or environmental pollutants. However, surprisingly very few data is currently available on its role in fish species which are directly exposed to frequent environmental perturbations. Here, we report that the treatment of fasted trout hepatocytes with the autophagy inhibitor Bafilomycine A1 lowered the mRNA levels of many of the gluconeogenesis-related genes and increased those of genes involved in intracellular lipid stores. Concurrently, intracellular free amino acid levels dropped and the expression of the main genes involved in the endoplasmic reticulum (ER) stress exhibited a sharp increase in autophagy inhibited cells. Together these results highlight the strong complexity of the crosstalk between ER, autophagy and metabolism and support the importance of considering this function in future studies on metabolic adaptation of fish to environmental stresses

    Motorized spiral enteroscopy: results of an international multicenter prospective observational clinical study in patients with normal and altered gastrointestinal anatomy

    Full text link
    BACKGROUND : Motorized spiral enteroscopy (MSE) has been shown to be safe and effective for deep enteroscopy in studies performed at expert centers with limited numbers of patients without previous abdominal surgery. This study aimed to investigate the safety, efficacy, and learning curve associated with MSE in a real-life scenario, with the inclusion of patients after abdominal surgery and with altered anatomy. METHODS : Patients with indications for deep enteroscopy were enrolled in a prospective observational multicenter study. The primary objective was the serious adverse event (SAE) rate; secondary objectives were the diagnostic and therapeutic yield, procedural success, time, and insertion depth. Data analysis was subdivided into training and core (post-training) study phases at centers with different levels of MSE experience. RESULTS : 298 patients (120 women; median age 68, range 19-92) were enrolled. In the post-training phase, 21.5 % (n = 54) had previous abdominal surgery, 10.0 % (n = 25) had surgically altered anatomy. Overall, SAEs occurred in 2.3 % (7/298; 95 %CI 0.9 %-4.8 %). The SAE rate was 2.0 % (5/251) in the core group and 4.3 % (2/47) in the training group, and was not increased after abdominal surgery (1.9 %). Total enteroscopy was achieved in half of the patients (n = 42) undergoing planned total enteroscopy. In 295/337 procedures (87.5 %), the anatomical region of interest could be reached. CONCLUSIONS : This prospective multicenter study showed that MSE was feasible and safe in a large cohort of patients in a real-life setting, after a short learning curve. MSE was shown to be feasible in postsurgical patients, including those with altered anatomy, without an increase in the SAE rate. Trial registration: ClinicalTrials.gov NCT03955081

    Revising the European Society of Gastrointestinal Endoscopy (ESGE) research priorities: a research progress update

    Get PDF
    AbstractBackground One of the aims of the European Society of Gastrointestinal Endoscopy (ESGE) is to encourage high quality endoscopic research at a European level. In 2016, the ESGE research committee published a set of research priorities. As endoscopic research is flourishing, we aimed to review the literature and determine whether endoscopic research over the last 4 years had managed to address any of our previously published priorities.Methods As the previously published priorities were grouped under seven different domains, a working party with at least two European experts was created for each domain to review all the priorities under that domain. A structured review form was developed to standardize the review process. The group conducted an extensive literature search relevant to each of the priorities and then graded the priorities into three categories: (1) no longer a priority (well-designed trial, incorporated in national/international guidelines or adopted in routine clinical practice); (2) remains a priority (i. e. the above criterion was not met); (3) redefine the existing priority (i. e. the priority was too vague with the research question not clearly defined).Results The previous ESGE research priorities document published in 2016 had 26 research priorities under seven domains. Our review of these priorities has resulted in seven priorities being removed from the list, one priority being partially removed, another seven being redefined to make them more precise, with eleven priorities remaining unchanged. This is a reflection of a rapid surge in endoscopic research, resulting in 27 % of research questions having already been answered and another 27 % requiring redefinition.Conclusions Our extensive review process has led to the removal of seven research priorities from the previous (2016) list, leaving 19 research priorities that have been redefined to make them more precise and relevant for researchers and funding bodies to target

    Exosomes released by EBV-infected nasopharyngeal carcinoma cells convey the viral Latent Membrane Protein 1 and the immunomodulatory protein galectin 9

    Get PDF
    BACKGROUND: Nasopharyngeal carcinomas (NPC) are consistently associated with the Epstein-Barr virus (EBV). Their malignant epithelial cells contain the viral genome and express several antigenic viral proteins. However, the mechanisms of immune escape in NPCs are still poorly understood. EBV-transformed B-cells have been reported to release exosomes carrying the EBV-encoded latent membrane protein 1 (LMP1) which has T-cell inhibitory activity. Although this report suggested that NPC cells could also produce exosomes carrying immunosuppressive proteins, this hypothesis has remained so far untested. METHODS: Malignant epithelial cells derived from NPC xenografts – LMP1-positive (C15) or negative (C17) – were used to prepare conditioned culture medium. Various microparticles and vesicles released in the culture medium were collected and fractionated by differential centrifugation. Exosomes collected in the last centrifugation step were further purified by immunomagnetic capture on beads carrying antibody directed to HLA class II molecules. Purified exosomes were visualized by electron microscopy and analysed by western blotting. The T-cell inhibitory activities of recombinant LMP1 and galectin 9 were assessed on peripheral blood mononuclear cells activated by CD3/CD28 cross-linking. RESULTS: HLA-class II-positive exosomes purified from C15 and C17 cell supernatants were containing either LMP1 and galectin 9 (C15) or galectin 9 only (C17). Recombinant LMP1 induced a strong inhibition of T-cell proliferation (IC50 = 0.17 nM). In contrast recombinant galectin 9 had a weaker inhibitory effect (IC50 = 46 nM) with no synergy with LMP1. CONCLUSION: This study provides the proof of concept that NPC cells can release HLA class-II positive exosomes containing galectin 9 and/or LMP1. It confirms that the LMP1 molecule has intrinsic T-cell inhibitory activity. These findings will encourage investigations of tumor exosomes in the blood of NPC patients and assessment of their effects on various types of target cells

    Endoscopic management of patients with high-risk colorectal colitis–associated neoplasia:a Delphi study

    Get PDF
    Background and Aims: Current guidelines recommend endoscopic resection of visible and endoscopically resectable colorectal colitis–associated neoplasia (CAN) in patients with inflammatory bowel disease (IBD). However, patients with high-risk CAN (HR-CAN) are often not amenable to conventional resection techniques, and a consensus approach for the endoscopic management of these lesions is presently lacking. This Delphi study aims to reach consensus among experts on the endoscopic management of these lesions. Methods: A 3-round modified Delphi process was conducted to reach consensus among worldwide IBD and/or endoscopy experts (n = 18) from 3 continents. Consensus was considered if ≥75% agreed or disagreed. Quality of evidence was assessed by the criteria of the Cochrane Collaboration group. Results: Consensus was reached on all statements (n = 14). Experts agreed on a definition for CAN and HR-CAN. Consensus was reached on the examination of the colon with enhanced endoscopic imaging before resection, the endoscopic resectability of an HR-CAN lesion, and endoscopic assessment and standard report of CAN lesions. In addition, experts agreed on type of resections of HR-CAN (20 mm, with or without good lifting), endoscopic success (technical success and outcomes), histologic assessment, and follow-up in HR-CAN. Conclusions: This is the first step in developing international consensus–based recommendations for endoscopic management of CAN and HR-CAN. Although the quality of available evidence was considered low, consensus was reached on several aspects of the management of CAN and HR-CAN. The present work and proposed standardization might benefit future studies

    Long-term follow-up after endoscopic resection for superficial esophageal squamous cell carcinoma: a multicenter Western studyAbstract

    Get PDF
    Background Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) are the first-line treatments for superficial esophageal squamous cell carcinoma (SCC). This study aimed to compare long-term clinical outcome and oncological clearance between EMR and ESD for the treatment of superficial esophageal SCC. Methods We conducted a retrospective multicenter study in five French tertiary care hospitals. Patients treated by EMR or ESD for histologically proven superficial esophageal SCC were included consecutively. Results Resection was performed for 148 tumors (80 EMR, 68 ESD) in 132 patients. The curative resection rate was 21.3 % in the EMR group and 73.5 % in the ESD group (P &lt; 0.001). The recurrence rate was 23.7 % in the EMR group and 2.9 % in the ESD group (P = 0.002). The 5-year recurrence-free survival rate was 73.4 % in the EMR group and 95.2 % in the ESD group (P = 0.002). Independent factors for cancer recurrence were resection by EMR (hazard ratio [HR] 16.89, P = 0.01), tumor infiltration depth ≥ m3 (HR 3.28, P = 0.02), no complementary treatment by chemoradiotherapy (HR 7.04, P = 0.04), and no curative resection (HR 11.75, P = 0.01). Risk of metastasis strongly increased in patients with tumor infiltration depth ≥ m3, and without complementary chemoradiotherapy (P = 0.02). Conclusion Endoscopic resection of superficial esophageal SCC was safe and efficient. Because it was associated with an increased recurrence-free survival rate, ESD should be preferred over EMR. For tumors with infiltration depths ≥ m3, chemoradiotherapy reduced the risk of nodal or distal metastasis

    Small-bowel capsule endoscopy with panoramic view: results of the first multicenter, observational study (with videos).

    Get PDF
    BACKGROUND AND AIMS: The first small-bowel video-capsule endoscopy (VCE) with 360° panoramic view has been recently developed. This new capsule has a wire-free technology, 4 high frame-rate cameras, and a long-lasting battery life. The present study was aimed at assessing performances and the safety profile of the 360° panoramic-view capsule in a large series of patients from a multicenter clinical practice setting. METHODS: Consecutive patients undergoing a 360° panoramic-view capsule procedure in 7 European Institutions between January 2011 and November 2015 were included. Both technical (ie, technical failures, completion rate) and clinical (ie, indication, findings, retention rate) data were collected by means of a structured questionnaire. VCE findings were classified according to the likelihood to explain reason for referral: P0-low, P1-intermediate and P2-high. RESULTS: Among 172 patients (94 men; median age: 68 years, IQR: 53-75), 142 underwent VCE for obscure (32 overt, 110 occult) GI bleeding (OGIB) and 28 for suspected (17) or established (2) Crohn's disease (CD). Overall, 560 findings were detected; 252 of them were P2. The overall diagnostic yield was 40.1%; 42.2% and 30.0% in patients with OGIB and CD, respectively. The rate of complete enteroscopy was 90.2%. All of the patients but one, who experienced capsule retention (1/172: 0.6%), excreted and retrieved the capsule. VCE failure occurred in 4 of 172 (2.3%) cases for technical problems. CONCLUSION: The present multicenter study, conducted in clinical practice setting and based on a large consecutive series of patients, showed that DY and safety profile of 360° panoramic-view capsule are similar to those of forward-view VCEs
    • …
    corecore