164 research outputs found

    All Coronal Loops are the Same: Evidence to the Contrary

    Full text link
    The 1998 April 20 spectral line data from the Coronal Diagnostics Spectrometer (CDS) on the {\it Solar and Heliospheric Observatory} (\SOHO) shows a coronal loop on the solar limb. Our original analysis of these data showed that the plasma was multi-thermal, both along the length of the loop and along the line of sight. However, more recent results by other authors indicate that background subtraction might change these conclusions, so we consider the effect of background subtraction on our analysis. We show Emission Measure (EM) Loci plots of three representative pixels: loop apex, upper leg, and lower leg. Comparisons of the original and background-subtracted intensities show that the EM Loci are more tightly clustered after background subtraction, but that the plasma is still not well represented by an isothermal model. Our results taken together with those of other authors indicate that a variety of temperature structures may be present within loops.Comment: Accepted for publication in ApJ Letter

    High-resolution spectro-polarimetry of a flaring sunspot penumbra

    Full text link
    We present simultaneous photospheric and chromospheric observations of the trailing sunspot in NOAA 10904 during a weak flare eruption (GOES magnitude B7.8), obtained with the Swedish Solar Telescope (SST) in La Palma, Canary Islands. High-resolution \ion{Ca}{ii} HH images show a typical two-ribbon structure that has been hitherto only known for larger flares, and the flare appears in a confined region that is discernible by a bright border. The underlying photosphere shows a disturbed penumbral structure with intersecting branches of penumbral filaments. High-resolution Doppler- and vector-magnetograms exhibit oppositely directed Evershed flows and magnetic field vectors in the individual penumbral branches, resulting in several regions of magnetic azimuth discontinuity and several islands where the vertical magnetic field is reversed. The discontinuity regions are co-spatial with the locations of the onset of the flare ribbons. From the results, we conclude that the confined flare region is detached from the global magnetic field structure by a separatrix marked by the bright border visible in \ion{Ca}{ii} HH. We further conclude that the islands of reversed vertical field appear because of flux emergence and that the strong magnetic shear appearing in the regions of magnetic azimuth discontinuity triggers the flare.Comment: 20 pages + 1 online Figure for A&

    Search for photospheric footpoints of quiet Sun transition region loops

    Full text link
    CONTEXT:The footpoints of quiet Sun Transition Region (TR) loops do not seem to coincide with the photospheric magnetic structures appearing in traditional low-sensitivity magnetograms. AIMS: To look for the so-far unidentified photospheric footpoints of TR loops using G-band bright points (BPs) as proxies for photospheric magnetic field concentrations. METHODS: Comparison of TR measurements with SoHO/SUMER and photospheric magnetic field observations obtained with the Dutch Open Telescope. RESULTS: Photospheric BPs are associated with bright TR structures, but they seem to avoid the brightest parts of the structure. BPs appear in regions that are globally redshifted, but they avoid extreme velocities. TR explosive events are not clearly associated with BPs. CONCLUSIONS: The observations are not inconsistent with the BPs being footpoints of TR loops, although we have not succeeded to uniquely identify particular BPs with specific TR loops.Comment: Accepted for publication in A&A. 10 pages, 10 figures. Due to size limitations, the quality of fig3 is not goo

    Toxicity of lunar dust

    Full text link
    The formation, composition and physical properties of lunar dust are incompletely characterised with regard to human health. While the physical and chemical determinants of dust toxicity for materials such as asbestos, quartz, volcanic ashes and urban particulate matter have been the focus of substantial research efforts, lunar dust properties, and therefore lunar dust toxicity may differ substantially. In this contribution, past and ongoing work on dust toxicity is reviewed, and major knowledge gaps that prevent an accurate assessment of lunar dust toxicity are identified. Finally, a range of studies using ground-based, low-gravity, and in situ measurements is recommended to address the identified knowledge gaps. Because none of the curated lunar samples exist in a pristine state that preserves the surface reactive chemical aspects thought to be present on the lunar surface, studies using this material carry with them considerable uncertainty in terms of fidelity. As a consequence, in situ data on lunar dust properties will be required to provide ground truth for ground-based studies quantifying the toxicity of dust exposure and the associated health risks during future manned lunar missions.Comment: 62 pages, 9 figures, 2 tables, accepted for publication in Planetary and Space Scienc

    Induction of SCEs and DNA fragmentation in bovine peripheral lymphocytes by in vitro exposure to tolylfluanid-based fungicide

    Get PDF
    The potential for genotoxic and cytotoxic effects of tolylfluanid-based fungicide (50% active agent) was evaluated using sister chromatid exchange (SCE) and proliferation indices (PI) in cultured bovine peripheral lymphocytes. For the detection of possible genetic damage, DNA fragmentation assay was also applied. Bovine lymphocytes cultured for 72 h were treated with the fungicide at the final concentrations of 1.75, 3.5, 8.75, and 17.5 μg/mL for the last 24 and 48 h of culture without S9 metabolic activation, and during the last 2 h of culture with S9 metabolic activation. In the SCE assays no evidence for genotoxic activity of the fungicide was found in treatments of 24 h without and 2 h with S9. After the 24 h exposure to tolylfluanid, a weak decrease in the PI was observed. With the prolonged exposure time (48 h), dose dependence in the increase of SCE frequencies was observed. Moreover, after 48 h exposure slight fragmentation of DNA at the concentrations of 3.5 and 8.75 μg/mL was demonstrated. SCE quantification is the most widely used approach for the assessment of genotoxic/cytogenetic effects of chemical compounds. Positive results in the assay at 48 h exposure indicated a potential of the fungicide to increase frequency of chromosomal damage (replication injuries) that is the confirmation of early effect of exposure

    Translational toxicology in setting occupational exposure limits for dusts and hazard classification – a critical evaluation of a recent approach to translate dust overload findings from rats to humans

    Get PDF
    Background We analyze the scientific basis and methodology used by the German MAK Commission in their recommendations for exposure limits and carcinogen classification of “granular biopersistent particles without known specific toxicity” (GBS). These recommendations are under review at the European Union level. We examine the scientific assumptions in an attempt to reproduce the results. MAK’s human equivalent concentrations (HECs) are based on a particle mass and on a volumetric model in which results from rat inhalation studies are translated to derive occupational exposure limits (OELs) and a carcinogen classification. Methods We followed the methods as proposed by the MAK Commission and Pauluhn 2011. We also examined key assumptions in the metrics, such as surface area of the human lung, deposition fractions of inhaled dusts, human clearance rates; and risk of lung cancer among workers, presumed to have some potential for lung overload, the physiological condition in rats associated with an increase in lung cancer risk. Results The MAK recommendations on exposure limits for GBS have numerous incorrect assumptions that adversely affect the final results. The procedures to derive the respirable occupational exposure limit (OEL) could not be reproduced, a finding raising considerable scientific uncertainty about the reliability of the recommendations. Moreover, the scientific basis of using the rat model is confounded by the fact that rats and humans show different cellular responses to inhaled particles as demonstrated by bronchoalveolar lavage (BAL) studies in both species. Conclusion Classifying all GBS as carcinogenic to humans based on rat inhalation studies in which lung overload leads to chronic inflammation and cancer is inappropriate. Studies of workers, who have been exposed to relevant levels of dust, have not indicated an increase in lung cancer risk. Using the methods proposed by the MAK, we were unable to reproduce the OEL for GBS recommended by the Commission, but identified substantial errors in the models. Considerable shortcomings in the use of lung surface area, clearance rates, deposition fractions; as well as using the mass and volumetric metrics as opposed to the particle surface area metric limit the scientific reliability of the proposed GBS OEL and carcinogen classification.International Carbon Black Associatio

    Pulmonary and systemic responses of highly pure and well-dispersed single-wall carbon nanotubes after intratracheal instillation in rats

    Get PDF
    The present study was conducted to assess the pulmonary and systemic responses in rats after intratracheal instillation of highly pure, well-dispersed, and well-characterized SWCNTs. Exposure to SWCNTs up to 2mg/kg did not produce mortality, changes in clinical signs, or body weights during the observation period. Dose-dependent changes were observed in the lung weight, BALF inflammatory cells, and biochemical parameters such as LDH value, protein content, IL-1β and IL-6 activity, and histopathology. In the 0.04 mg/kg SWCNT-exposed group, almost no changes were observed during the observation period. In the 0.2 mg/kg SWCNT-exposed group, pulmonary inflammatory responses were observed after instillation. In the 1 mg/kg and 2 mg/kg SWCNT-exposed group, acute lung inflammation and subsequent granuloma accompanied by increased lung weights were observed. Furthermore, the histopathological findings in the lungs of rats exposed to SWCNTs showed inflammatory responses related with the vital reaction to the foreign substance that was instilled intratracheally, and there were no fibrosis, atypical lesion, or tumor-related findings even at the highest dose (2 mg/kg) of SWCNT-exposed groups up to 6 months after instillation. For all groups, histopathological changes due to the instillation exposure of SWCNTs were observed only in the lungs and lung-associated lymph nodes and not in the other tissues examined (i.e. the liver, kidney, spleen, and cerebrum)

    FIB-SEM imaging of carbon nanotubes in mouse lung tissue

    Get PDF
    Ultrastructural characterisation is important for understanding carbon nanotube (CNT) toxicity and how the CNTs interact with cells and tissues. The standard method for this involves using transmission electron microscopy (TEM). However, in particular, the sample preparation, using a microtome to cut thin sample sections for TEM, can be challenging for investigation of regions with agglomerations of large and stiff CNTs because the CNTs cut with difficulty. As a consequence, the sectioning diamond knife may be damaged and the uncut CNTs are left protruding from the embedded block surface excluding them from TEM analysis. To provide an alternative to ultramicrotomy and subsequent TEM imaging, we studied focused ion beam scanning electron microscopy (FIB-SEM) of CNTs in the lungs of mice, and we evaluated the applicability of the method compared to TEM. FIB-SEM can provide serial section volume imaging not easily obtained with TEM, but it is time-consuming to locate CNTs in the tissue. We demonstrate that protruding CNTs after ultramicrotomy can be used to locate the region of interest, and we present FIB-SEM images of CNTs in lung tissue. FIB-SEM imaging was applied to lung tissue from mice which had been intratracheally instilled with two different multiwalled CNTs; one being short and thin, and the other longer and thicker. FIB-SEM was found to be most suitable for detection of the large CNTs (Ø ca. 70 nm), and to be well suited for studying CNT agglomerates in biological samples which is challenging using standard TEM techniques. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-013-7566-x) contains supplementary material, which is available to authorized users

    Transcriptomic Analysis Reveals Novel Mechanistic Insight into Murine Biological Responses to Multi-Walled Carbon Nanotubes in Lungs and Cultured Lung Epithelial Cells

    Get PDF
    There is great interest in substituting animal work with in vitro experimentation in human health risk assessment; however, there are only few comparisons of in vitro and in vivo biological responses to engineered nanomaterials. We used high-content genomics tools to compare in vivo pulmonary responses of multiwalled carbon nanotubes (MWCNT) to those in vitro in cultured lung epithelial cells (FE1) at the global transcriptomic level. Primary size, surface area and other properties of MWCNT- XNRI -7 (Mitsui7) were characterized using DLS, SEM and TEM. Mice were exposed via a single intratracheal instillation to 18, 54, or 162 μg of Mitsui7/mouse. FE1 cells were incubated with 12.5, 25 and 100 μg/ml of Mitsui7. Tissue and cell samples were collected at 24 hours post-exposure. DNA microarrays were employed to establish mechanistic differences and similarities between the two models. Microarray results were confirmed using gene-specific RT-qPCR. Bronchoalveolar lavage (BAL) fluid was assessed for indications of inflammation in vivo. A strong dose-dependent activation of acute phase and inflammation response was observed in mouse lungs reflective mainly of an inflammatory response as observed in BAL. In vitro, a wide variety of core cellular functions were affected including transcription, cell cycle, and cellular growth and proliferation. Oxidative stress, fibrosis and inflammation processes were altered in both models. Although there were similarities observed between the two models at the pathway-level, the specific genes altered under these pathways were different, suggesting that the underlying mechanisms of responses are different in cells in culture and the lung tissue. Our results suggest that careful consideration should be given in selecting relevant endpoints when substituting animal with in vitro testing
    corecore