103 research outputs found

    Linezolid population pharmacokinetic model in plasma and cerebrospinal fluid among patients with tuberculosis meningitis

    Get PDF
    BACKGROUND: Linezolid is evaluated in novel treatment regimens for tuberculous meningitis (TBM). Linezolid pharmacokinetics have not been characterized in this population, particularly in cerebrospinal fluid (CSF) where exposures may be affected by changes in protein concentration. Linezolid co-administration with high-dose rifampicin, has also not been studied. We aimed to characterize linezolid plasma and CSF pharmacokinetics in adults with TBM. METHODS: In LASER-TBM pharmacokinetic-substudy, the intervention groups received high-dose rifampicin (35mg/kg) plus linezolid 1200mg/day for 28days, then reduced to 600mg/day. Plasma sampling was done on day 3 (intensive) and on day 28 (sparse). A lumbar CSF sample was obtained on both visits. RESULTS: 30-participants, median(min-max) age and weight of 40(27-56)years and 58(30-96)kg, contributed 247 plasma and 28 CSF observations. Plasma pharmacokinetics was described by one-compartment model with first-order absorption and saturable elimination. Maximal clearance was 7.25L/h, and Km was 27.2mg/L. Rifampicin co-treatment duration did not affect linezolid pharmacokinetics. CSF-Plasma partitioning correlated with CSF total-protein upto 1.2g/L where the partition-coefficient reached maximal value of 37%. Plasma-CSF equilibration half-life was ∌3.5hours. CONCLUSION: Linezolid was readily detected in CSF despite high-dose rifampicin co-administration. These findings support continued clinical evaluation of linezolid plus high-dose rifampicin for the treatment of TBM in adults

    Validation of the Aura Microwave Limb Sounder HNOmeasurements

    Get PDF
    We assess the quality of the version 2.2 (v2.2) HNO3 measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS HNO3 product has been greatly improved over that in the previous version (v1.5), with smoother profiles, much more realistic behavior at the lowest retrieval levels, and correction of a high bias caused by an error in one of the spectroscopy files used in v1.5 processing. The v2.2 HNO3 data are scientifically useful over the range 215 to 3.2 hPa, with single-profile precision of ∌0.7 ppbv throughout. Vertical resolution is 3–4 km in the upper troposphere and lower stratosphere, degrading to ∌5 km in the middle and upper stratosphere. The impact of various sources of systematic uncertainty has been quantified through a comprehensive set of retrieval simulations. In aggregate, systematic uncertainties are estimated to induce in the v2.2 HNO3 measurements biases that vary with altitude between ±0.5 and ±2 ppbv and multiplicative errors of ±5–15% throughout the stratosphere, rising to ∌±30% at 215 hPa. Consistent with this uncertainty analysis, comparisons with correlative data sets show that relative to HNO3 measurements from ground-based, balloon-borne, and satellite instruments operating in both the infrared and microwave regions of the spectrum, MLS v2.2 HNO3 mixing ratios are uniformly low by 10–30% throughout most of the stratosphere. Comparisons with in situ measurements made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost stratosphere indicate that the MLS HNO3 values are low in this region as well, but are useful for scientific studies (with appropriate averaging)

    Validation of Aura Microwave Limb Sounder O-3 and CO observations in the upper troposphere and lower stratosphere

    Get PDF
    International audienceGlobal satellite observations of ozone and carbon monoxide from the Microwave Limb Sounder (MLS) on the EOS Aura spacecraft are discussed with emphasis on those observations in the 215–100 hPa region (the upper troposphere and lower stratosphere). The precision, resolution and accuracy of the data produced by the MLS “version 2.2” processing algorithms are discussed and quantified. O3 accuracy is estimated at ~40 ppbv +5% (~20 ppbv +20% at 215 hPa) while the CO accuracy is estimated at ~30 ppbv +30% for pressures of 147 hPa and less. Comparisons with expectations and other observations show good agreements for the O3 product, generally consistent with the systematic errors quoted above. In the case of CO, a persistent factor of ~2 high bias is seen at 215 hPa. However, the morphology is shown to be realistic, consistent with raw MLS radiance data, and useful for scientific study. The MLS CO data at higher altitudes are shown to be consistent with other observations

    The Global ECT-MRI Research Collaboration (GEMRIC): Establishing a multi-site investigation of the neural mechanisms underlying response to electroconvulsive therapy.

    Get PDF
    Major depression, currently the world's primary cause of disability, leads to profound personal suffering and increased risk of suicide. Unfortunately, the success of antidepressant treatment varies amongst individuals and can take weeks to months in those who respond. Electroconvulsive therapy (ECT), generally prescribed for the most severely depressed and when standard treatments fail, produces a more rapid response and remains the most effective intervention for severe depression. Exploring the neurobiological effects of ECT is thus an ideal approach to better understand the mechanisms of successful therapeutic response. Though several recent neuroimaging studies show structural and functional changes associated with ECT, not all brain changes associate with clinical outcome. Larger studies that can address individual differences in clinical and treatment parameters may better target biological factors relating to or predictive of ECT-related therapeutic response. We have thus formed the Global ECT-MRI Research Collaboration (GEMRIC) that aims to combine longitudinal neuroimaging as well as clinical, behavioral and other physiological data across multiple independent sites. Here, we summarize the ECT sample characteristics from currently participating sites, and the common data-repository and standardized image analysis pipeline developed for this initiative. This includes data harmonization across sites and MRI platforms, and a method for obtaining unbiased estimates of structural change based on longitudinal measurements with serial MRI scans. The optimized analysis pipeline, together with the large and heterogeneous combined GEMRIC dataset, will provide new opportunities to elucidate the mechanisms of ECT response and the factors mediating and predictive of clinical outcomes, which may ultimately lead to more effective personalized treatment approaches

    Validation of the Aura Microwave Limb Sounder HNO3 Measurements

    Get PDF
    We assess the quality of the version 2.2 (v2.2) HNO3 measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS HNO3 product has been greatly improved over that in the previous version (v1.5), with smoother profiles, much more realistic behavior at the lowest retrieval levels, and correction of a high bias caused by an error in one of the spectroscopy files used in v1.5 processing. The v2.2 HNO3 data are scientifically useful over the range 215 to 3.2 hPa, with single-profile precision of 0.7 ppbv throughout. Vertical resolution is 3–4 km in the upper troposphere and lower stratosphere, degrading to 5 km in the middle and upper stratosphere. The impact of various sources of systematic uncertainty has been quantified through a comprehensive set of retrieval simulations. In aggregate, systematic uncertainties are estimated to induce in the v2.2 HNO3 measurements biases that vary with altitude between ±0.5 and ±2 ppbv and multiplicative errors of ±5–15% throughout the stratosphere, rising to ±30% at 215 hPa. Consistent with this uncertainty analysis, comparisons with correlative data sets show that relative to HNO3 measurements from ground-based, balloon-borne, and satellite instruments operating in both the infrared and microwave regions of the spectrum, MLS v2.2 HNO3 mixing ratios are uniformly low by 10–30% throughout most of the stratosphere. Comparisons with in situ measurements made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost stratosphere indicate that the MLS HNO3 values are low in this region as well, but are useful for scientific studies (with appropriate averaging).PublishedD24S401.7. Osservazioni di alta e media atmosferaJCR Journalreserve

    Diagnostic Accuracy of MRI and Additional [F-18]FDG-PET for Behavioral Variant Frontotemporal Dementia in Patients with Late Onset Behavioral Changes

    Get PDF
    BACKGROUND: Neuroimaging has a reasonable accuracy to differentiate behavioral variant frontotemporal dementia (bvFTD) from other neurodegenerative disorders, its value for the differentiation of bvFTD among subjects with acquired behavioral disturbances is unknown. OBJECTIVE: To determine the diagnostic accuracy of MRI, additional [18F]FDG-PET, and their combination for bvFTD among subjects with late onset behavioral changes. METHODS: Patients with late onset behavioral changes referred to a memory clinic or psychiatric services were included. At baseline, 111 patients had a brain MRI scan and 74 patients received an additional [18F]FDG-PET when the MRI was inconclusive. The consensus diagnosis after two-year-follow-up was used as the gold standard to calculate sensitivity and specificity for baseline neuroimaging. RESULTS: 27 patients had probable/definite bvFTD and 84 patients had a non-bvFTD diagnosis (primary psychiatric diagnosis or other neurological disorders). MRI had a sensitivity of 70% (95% CI 52–85%) with a specificity of 93% (95% CI 86–97%). Additional [18F]FDG-PET had a sensitivity of 90% (95% CI 66–100%) with a specificity of 68% (95% CI 56–79%). The sensitivity of combined neuroimaging was 96% (95% CI 85–100%) with a specificity of 73% (95% CI 63–81%). In 66% of the genetic FTD cases, MRI lacked typical frontotemporal atrophy. 40% of cases with a false positive [18F]FDG-PET scan had a primary psychiatric diagnosis. CONCLUSION: A good diagnostic accuracy was found for MRI and additional [18F]FDG-PET for bvFTD in patients with late onset behavioral changes. Caution with the interpretation of neuroimaging results should especially be taken in cases with a genetic background and in cases with a primary psychiatric differential diagnosis where [18F]FDG-PET is the only abnormal investigation

    Validation of the Aura Microwave Limb Sounder Temperature and Geopotential Height Measurements

    Get PDF
    Global satellite observations of temperature and geopotential height (GPH) from the Microwave Limb Sounder (MLS) on the EOS Aura spacecraft are discussed. The precision, resolution, and accuracy of the data produced by the MLS version 2.2 processing algorithms are quantified, and recommendations for data screening are made. Temperature precision is 1 K or better from 316 hPa to 3.16 hPa, degrading to ∌3 K at 0.001 hPa. The vertical resolution is 3 km at 31.6 hPa, degrading to 6 km at 316 hPa and to ∌13 km at 0.001 hPa. Comparisons with analyses (Goddard Earth Observing System version 5.0.1 (GEOS-5), European Centre for Medium-range Weather Forecasts (ECMWF), Met Office (MetO)) and other observations (CHAllenging Minisatellite Payload (CHAMP), Atmospheric Infrared Sounder/Advanced Microwave Sounder Unit (AIRS/AMSU), Sounding of the Atmosphere using Broadband Radiometry (SABER), Halogen Occultation Experiment (HALOE), Atmospheric Chemistry Experiment (ACE), radiosondes) indicate that MLS temperature has persistent, pressure-dependent biases which are between −2.5 K and +1 K between 316 hPa and 10 hPa. The 100-hPa MLS v2.2 GPH surface has a bias of ∌150 m relative to the GEOS-5 values. These biases are compared to modeled systematic uncertainties. GPH biases relative to correlative measurements generally increase with height owing to an overall cold bias in MLS temperature relative to correlative temperature measurements in the upper stratosphere and mesosphere

    Quality of life, psychological morbidity and family stress in elderly residing in the community

    Get PDF
    Este estudo procurou investigar as relaçÔes existentes entre morbilidade psicolĂłgica, stress familiar e qualidade de vida (QV) da pessoa idosa. A amostra foi constituĂ­da por 126 idosos. Os instrumentos utilizados foram: The Lawton Instrumental Activities of Daily Living (IADL), Quality of Life (WHOQOL-Bref), Geriatric Anxiety Inventory (GSI), Geriatric Depression Scale (GDS); e Index of Family Relations (IFR). Os resultados revelaram a importĂąncia da idade, estado civil, escolaridade e nĂșmero de patologias assim como o gĂ©nero na capacidade funcional, morbilidade, stress familiar e QV. Ao nĂ­vel dos preditores, a depressĂŁo foi a variĂĄvel que mais contribuiu para a QV. NĂŁo foram encontradas variĂĄveis moderadoras no modelo. A discussĂŁo e implicaçÔes dos resultados sĂŁo abordadas bem como a intervenção psicolĂłgica nesta população.This study sought to understand the relationships among psychological morbidity, family stress and quality of life (QL) of elderly. The sample consisted of 126 elderly. The following instruments were used: the Lawton Instrumental Activities of Daily Living (IADL); Quality of Life (WHOQOL-Bref), Geriatric Anxiety Inventory (GSI), Geriatric Depression Scale (GDS), and the Index of Family Relations (IFR). Results revealed the importance of age, marital status, education and number of pathologies as well as gender on functional capacity, morbidity, family stress and QV. In terms of predictors, depression was the variable that contributed the most to QL. There were no moderating variables in the model. Discussion and implications of results are addressed as well as psychological interventions.(undefined
    • 

    corecore