593 research outputs found

    Current density distribution in cylindrical Li-Ion cells during impedance measurements

    Get PDF
    In this work, modified commercial cylindrical lithium-ion cells with multiple separate current tabs are used to analyze the influence of tab pattern, frequency and temperature on electrochemical impedance spectroscopy. In a first step, the effect of different current tab arrangements on the impedance spectra is analyzed and possible electrochemical causes are discussed. In a second step, one terminal is used to apply a sinusoidal current while the other terminals are used to monitor the local potential distribution at different positions along the electrodes of the cell. It is observed that the characteristic decay of the voltage amplitude along the electrode changes non-linearly with frequency, where high-frequent currents experience a stronger attenuation along the current collector than low-frequent currents. In further experiments, the decay characteristic is controlled by the cell temperature, driven by the increasing resistance of the current collector and the enhanced kinetic and transport properties of the active material and electrolyte. Measurements indicate that the ac current distribution depends strongly on the frequency and the temperature. In this context, the challenges for electrochemical impedance spectroscopy as cell diagnostic technique for commercial cells are discussed

    A Very Intense Neutrino Super Beam Experiment for Leptonic CP Violation Discovery based on the European Spallation Source Linac: A Snowmass 2013 White Paper

    Full text link
    Very intense neutrino beams and large neutrino detectors will be needed in order to enable the discovery of CP violation in the leptonic sector. We propose to use the proton linac of the European Spallation Source currently under construction in Lund, Sweden to deliver, in parallel with the spallation neutron production, a very intense, cost effective and high performance neutrino beam. The baseline program for the European Spallation Source linac is that it will be fully operational at 5 MW average power by 2022, producing 2 GeV 2.86 ms long proton pulses at a rate of 14 Hz. Our proposal is to upgrade the linac to 10 MW average power and 28 Hz, producing 14 pulses/s for neutron production and 14 pulses/s for neutrino production. Furthermore, because of the high current required in the pulsed neutrino horn, the length of the pulses used for neutrino production needs to be compressed to a few μ\mus with the aid of an accumulator ring. A long baseline experiment using this Super Beam and a megaton underground Water Cherenkov detector located in existing mines 300-600 km from Lund will make it possible to discover leptonic CP violation at 5 σ\sigma significance level in up to 50% of the leptonic Dirac CP-violating phase range. This experiment could also determine the neutrino mass hierarchy at a significance level of more than 3 σ\sigma if this issue will not already have been settled by other experiments by then. The mass hierarchy performance could be increased by combining the neutrino beam results with those obtained from atmospheric neutrinos detected by the same large volume detector. This detector will also be used to measure the proton lifetime, detect cosmological neutrinos and neutrinos from supernova explosions. Results on the sensitivity to leptonic CP violation and the neutrino mass hierarchy are presented.Comment: 28 page

    Prospective Assessment of Sex-Related Differences in Symptom Status and Health Perception Among Patients With Atrial Fibrillation.

    Get PDF
    We prospectively assessed sex-specific differences in health perception, overall symptom status, and specific symptoms in a large cohort of patients with atrial fibrillation. We performed a prospective multicenter observational cohort study of 1553 patients with atrial fibrillation. Patients completed questionnaires about personal characteristics, comorbidities, and symptoms on a yearly basis. Mean age was 70±11 years among women and 67±12 years among men. Health perception on a visual analogue scale ranging from 0 to 100 (with higher scores indicating better health perception) was significantly lower in women than in men (70 [interquartile range: 50-80] versus 75 [interquartile range: 60-85]; javax.xml.bind.JAXBElement@29592a5d <0.0001). More women than men had any symptoms (85.0% versus 68.3%; javax.xml.bind.JAXBElement@7ac0b4e4 <0.0001), palpitations (65.2% versus 44.4%; javax.xml.bind.JAXBElement@41229466 <0.0001), dizziness (25.6% versus 13.5%; javax.xml.bind.JAXBElement@61871784 <0.0001), dyspnea (35.7% versus 21.8%; javax.xml.bind.JAXBElement@16cc22b <0.0001), and fatigue (25.3% versus 19.1%; javax.xml.bind.JAXBElement@7ef43176 =0.006). At 1-year follow-up, symptoms decreased in both sexes but remained more frequent in women (49.1% versus 32.6%, javax.xml.bind.JAXBElement@2b200b6a <0.0001). In multivariable adjusted longitudinal regression models, female sex remained an independent predictor for lower health perception (ß=-4.8; 95% CI, -6.5 to -3.1; javax.xml.bind.JAXBElement@72c212bd <0.0001), any symptoms (odds ratio [OR]: 2.6; 95% CI, 2.1-3.4; javax.xml.bind.JAXBElement@15d8fb54 <0.0001), palpitations (OR: 2.6; 95% CI, 2.1-3.2; javax.xml.bind.JAXBElement@4af80718 <0.0001), dizziness (OR: 2.9; 95% CI, 2.1-3.9; javax.xml.bind.JAXBElement@61282e76 <0.0001), dyspnea (OR: 2.1; 95% CI, 1.6-2.8; javax.xml.bind.JAXBElement@31d9f14 <0.0001), fatigue (OR: 1.6; 95% CI, 1.2-2.2; javax.xml.bind.JAXBElement@51cdd678 =0.0008), and chest pain (OR: 1.8; 95% CI, 1.3-2.6; javax.xml.bind.JAXBElement@5b87db9e =0.001). Women with atrial fibrillation have a substantially higher symptom burden and lower health perception than men. These relationships persisted after multivariable adjustment and during prospective follow-up

    Temperature dependency of state of charge inhomogeneities and their equalization in cylindrical lithium-ion cells

    Get PDF
    The influence of cell temperature on the current density distribution and accompanying inhomogeneities in state of charge (SOC) during cycling is analyzed in this work. To allow for a detailed insight in the electrochemical behavior of the cell, commercially available 26650 cells were modified to allow for measuring local potentials at four different, nearly equidistant positions along the electrodes. As a follow-up to our previous work investigating local potentials within a cell, we apply this method for studying SOC deviations and their sensitivity to cell temperature. The local potential distribution was studied during constant current discharge operations for various current rates and discharge pulses in order to evoke local inhomogeneities for temperatures ranging from 10 °C to 40 °C. Differences in local potentials were considered for estimating local SOC variations within the electrodes. It could be observed that even low currents such as 0.1C can lead to significant inhomogeneities, whereas a higher cell temperature generally results in more pronounced inhomogeneities. A rapid SOC equilibration can be observed if the variation in the SOC distribution corresponds to a considerable potential difference defined by the open circuit voltage of either the positive or negative electrode. With increasing temperature, accelerated equalization effects can be observed

    Design of the Swiss Atrial Fibrillation Cohort Study (Swiss-AF): structural brain damage and cognitive decline among patients with atrial fibrillation.

    Get PDF
    Several studies found that patients with atrial fibrillation (AF) have an increased risk of cognitive decline and dementia over time. However, the magnitude of the problem, associated risk factors and underlying mechanisms remain unclear. This article describes the design and methodology of the Swiss Atrial Fibrillation (Swiss-AF) Cohort Study, a prospective multicentre national cohort study of 2400 patients across 13 sites in Switzerland. Eligible patients must have documented AF. Main exclusion criteria are the inability to provide informed consent and the presence of exclusively short episodes of reversible forms of AF. All patients undergo extensive phenotyping and genotyping, including repeated assessment of cognitive functions, quality of life, disability, electrocardiography and cerebral magnetic resonance imaging. We also collect information on health related costs, and we assemble a large biobank. Key clinical outcomes in Swiss-AF are death, stroke, systemic embolism, bleeding, hospitalisation for heart failure and myocardial infarction. Information on outcomes and updates on other characteristics are being collected during yearly follow-up visits. Up to 7 April 2017, we have enrolled 2133 patients into Swiss-AF. With the current recruitment rate of 15 to 20 patients per week, we expect that the target sample size of 2400 patients will be reached by summer 2017. Swiss-AF is a large national prospective cohort of patients with AF in Switzerland. This study will provide important new information on structural and functional brain damage in patients with AF and on other AF related complications, using a large variety of genetic, phenotypic and health economic parameters

    High intensity neutrino oscillation facilities in Europe

    Get PDF
    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ+ and μ− beams in a storage ring. The far detector in this case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular He6 and Ne18, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive
    corecore