239 research outputs found

    Accuracy of urine pH testing in a regional metabolic renal clinic: is the dipstick accurate enough?

    Get PDF
    Urine pH is a useful marker for assessing treatment need and efficacy in patients with nephrolithiasis. Though the gold standard of measurement is with a pH electrode, dipsticks offer the convenience of cost, ease of use, and the possibility of patients measuring their own values outside the clinic. The aim of this study was to determine whether dipsticks offer the same accuracy as the electrode. Paired measurements of freshly voided urine pH with both electrode and dipstick were analysed in a multidisciplinary renal clinic. We found that although there was a high Pearson correlation between the samples (0.89, p = 0.001), urine dipstick measurements carried an approximately 1 in 4 risk of producing clinically significant differences (pH differences  > 0.5 pH unit) from meter values. We also found that at high and low urine pH, the dipstick tended to over- and underestimate true pH readings, respectively. Examining the values in the 98 patients where a need for pharmacological urinary pH manipulation was indicated by the true pH, we found 14 who would not have been appropriately treated, and 5 who would have been unnecessarily medicated, if the stick pH value had been used. We conclude that dipstick pH measurement is insufficiently reliable for guiding clinical decision-making

    Impact of Ureteral Stent Material on Stent-related Symptoms: A Systematic Review of the Literature

    Full text link
    CONTEXT Ureteral stents are essential implants that are used on a daily basis. Since their invention, advances in stent design have been directed towards alleviating stent-related symptoms. It remains unclear how the material composition of the stent affects stent-related symptoms. OBJECTIVE To review the literature and define the clinical impact of ureteral stent material on stent-related symptoms. EVIDENCE ACQUISITION A literature search of the Embase, MEDLINE (PubMed), and Web of Science databases was conducted on December 17, 2021 to collect articles comparing stent composition materials regarding stent-related symptoms. Thirteen publications met the inclusion criteria, of which only one met the high-quality requirements of the Cochrane Collaboration tool for assessing the risk of bias in randomized trials. EVIDENCE SYNTHESIS Most trials, including the highest quality trial, seem to support that silicone double-J (DJ) stents reduce stent-related symptoms compared to nonsilicone DJ stents. Regarding physical properties, it seems that "soft" or "flexible" DJ stents reduce stent-related symptoms. However, since there was only one high-quality study with a low risk of bias, it is impossible to draw a definitive conclusion owing to the lack of quality data. CONCLUSIONS Silicone DJ stents, and by extension "soft" DJ stents, appear to reduce stent-related symptoms compared to nonsilicone polymers and "hard" DJ stents. No definitive conclusion can be drawn owing to a lack of quality evidence. Creating a standard for measuring and reporting physical stent properties should be the first step for further research. PATIENT SUMMARY A ureteral stent is a small hollow tube placed inside the ureter to help urine drain from the kidney. We reviewed the literature on the impact of stent material on stent-related symptoms. We found that silicone may reduce stent-related symptoms, but no definitive conclusion can be drawn and further studies are needed

    Investigating upper urinary tract urothelial carcinomas: a single-centre 10-year experience.

    Get PDF
    OBJECTIVES: Evidence of the accuracy of predictive tests in confirming the presence and grade of upper urinary tract urothelial carcinomas (UUTUC) is limited. We present the largest series evaluating the diagnostic value of pre- and intra-operative parameters in the detection of UUTUC. MATERIALS AND METHODS: We retrospectively analysed records of patients who underwent diagnostic ureteroscopy between 2005 and 2014 for suspected UUTUC. Pre-operative workup included voided urine cytology and CT imaging. Intra-operative assessments involved ureteroscopy to directly visualise suspicious lesions, and where possible selective cytology and biopsy. Primary outcomes were the visualisation of UUTUC and histopathological confirmation of tumour. RESULTS: Hundred out of 160 (63 %) patients presenting with suspected upper tract malignancy had UUTUC. Voided and selective urine cytology and CT individually predicted UUTUC with a sensitivity/specificity of 63/67, 76/73, and 95/26 %, respectively. Forty out of 48 (83 %) patients who had abnormal CT and abnormal voided urine cytology had UUTUC, while 100 % of those with normal CT and normal voided cytology (investigated for ongoing symptoms) were normal. Comparing endoscopic biopsy to nephroureterectomy specimen grade, 19 (46 %), 18 (44 %), and 4 (10 %) were identical, upgraded, and downgraded, respectively. CONCLUSION: Pre-operative investigations can predict UUTUCs. When these investigations were normal, the risk of UUTUC is negligible. In selective patients with abnormal investigations, ureteroscopy should be performed to confirm and predict the grade of UUTUC, in order to guide future management. Selective cytology is unlikely to significantly contribute to the diagnostic workup of UUTUC.This is the author accepted manuscript. It is currently under an indefinite embargo pending publication by Springer

    Embedded Research::a promising way to create evidence-informed impact in public health?

    Get PDF
    Background Embedded research (ER) is recognized as one way to strengthen the integration of evidence into public health (PH) practice. In this paper, we outline a promising example of the co-production of research evidence between Fuse, the UKCRC Centre for Translational Research in Public Health and a local authority (LA) in north east England. Methods We critically examine attempts to share and use research findings to influence decision-making in a LA setting, drawing on insights from PH practitioners, managers, commissioners and academic partners involved in this organizational case study. We highlight what can be achieved as a co-located embedded researcher. Results The benefits and risks of ER are explored, alongside our reflections on the added value of this approach and the institutional prerequisites necessary for it to work. We argue that while this is not a new methodological approach, its application in PH as a way to facilitate evidence use is novel, and raises pragmatic and theoretical questions about the nature of impact and the extent to which it can be engineered. Conclusion With increased situated understanding of organizational culture and norms and greater awareness of the socio-political realities of PH, ER enables new co-produced solutions to become possible

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 102210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200

    Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

    Get PDF
    We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi

    Single molecule fluorescence for membrane proteins

    Get PDF
    The cell membrane is a complex milieu of lipids and proteins. In order to understand the behaviour of individual molecules is it often desirable to examine them as purified components in in vitro systems. Here, we detail the creation and use of droplet interface bilayers (DIBs) which, when coupled to TIRF microscopy, can reveal spatiotemporal and kinetic information for individual membrane proteins. A number of steps are required including modification of the protein sequence to enable the incorporation of appropriate fluorescent labels, expression and purification of the membrane protein and subsequent labelling. Following creation of DIBs, proteins are spontaneously incorporated into the membrane where they can be imaged via conventional single molecule TIRF approaches. Using this strategy, in conjunction with step-wise photobleaching, FRET and / or single particle tracking, a host of parameters can be determined such as oligomerisation state and dynamic information. We discuss advantages and limitations of this system and offer guidance for successful implementation of these approaches
    corecore