268 research outputs found
Comportamento ''in vitro" de uma bactéria fitopatogênica frente a diversos antibióticos
The present paper deals with study of the resistance against five antibiotics in a phytopathogenic bacterium Xanthomonas campestris (Pammel) Dowson. When the antibiotics were added to the solid medium in which the bacteria were grown, the colonies resistant to the streptomycin and erythromycin appeared even in the highest concentration used; as to the penicillin, aureomycin and cloranfenicol when in concentrations higher than 200 mcg/ml, 0,3 mcg/ml and 128 mcg/ml respectively, resistant colonies did not appear. So, the results show that the penicillin was the least efficient antibiotic and aureomycin the most effetive to Xanthomonas campestris.Foi estudada a resistência da bactéria fitopatogênica Xanthomonas campestris com relação a cinco antibióticos. Quando os antibióticos foram adicionados ao meio sólido no qual a bactéria iria se desenvolver, colônias resistentes à estreptomicina e éritromicina, apareceram até nas mais altas concentrações usadas. No caso da penicilina, aureomicina e cloranfenicol, em concentrações superiores a 200 mcg/ml, 0,3 mcg/ml e 128 mcg/ml respectivamente, não apareceram colônias resistentes. Os resultados mostraram que a penicilina foi o antibiótico menos efetivo e a aureomicina a mais efetiva em inibir o crescimento de X. campestris. Os resultados sugerem também que o modêlo de resistência à estreptomicina e éritromicina é o de um só passo enquanto que o modêlo de resistência aos três outros antibióticos ensaiados, é o de múltiplos passos
Single electron quantum tomography in quantum Hall edge channels
We propose a quantum tomography protocol to measure single electron coherence
in quantum Hall edge channels and therefore access for the first time the wave
function of single electron excitations propagating in ballistic quantum
conductors. Its implementation would open the way to quantitative studies of
single electron decoherence and would provide a quantitative tool for analyzing
single to few electron sources. We show how this protocol could be implemented
using ultrahigh sensitivity noise measurement schemes.Comment: Version 3: long version (7 figures): corrections performed and
references have been added. Figures reprocessed for better readabilit
Sudan Black B treatment reduces autofluorescence and improves resolution of in situ hybridization specific fluorescent signals of brain sections
Interference by autofluorescence is one of the major concerns of immunofluorescence analysis of in situ hybridization-based diagnostic assays. We present a useful technique that reduces autofluorescent background without affecting the tissue integrity or direct immunofluorescence signals in brain sections. Using six different protocols, such as ammonia/ethanol, Sudan Black B (SBB) in 70% ethanol, photobleaching with UV light and different combinations of them in both formalin-fixed paraffin-embedded and frozen human brain tissue sections, we have found that tissue treatment of SBB in a concentration of 0.1% in 70% ethanol is the best approach to reduce/eliminate tissue autofluorescence and background, while preserving the specific fluorescence hybridization signals. This strategy is a feasible, non-time consuming method that provides a reasonable compromise between total reduction of the tissue autofluorescence and maintenance of specific fluorescent labels.Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)[2007/56146-2]Comissao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)[1429/08-6
Probing quantum and thermal noise in an interacting many-body system
The probabilistic character of the measurement process is one of the most
puzzling and fascinating aspects of quantum mechanics. In many-body systems
quantum mechanical noise reveals non-local correlations of the underlying
many-body states. Here, we provide a complete experimental analysis of the
shot-to-shot variations of interference fringe contrast for pairs of
independently created one-dimensional Bose condensates. Analyzing different
system sizes we observe the crossover from thermal to quantum noise, reflected
in a characteristic change in the distribution functions from Poissonian to
Gumbel-type, in excellent agreement with theoretical predictions based on the
Luttinger liquid formalism. We present the first experimental observation of
quasi long-range order in one-dimensional atomic condensates, which is a
hallmark of quantum fluctuations in one-dimensional systems. Furthermore, our
experiments constitute the first analysis of the full distribution of quantum
noise in an interacting many-body system
Design and Performance of the XENON10 Dark Matter Experiment
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously
New results on solar neutrino fluxes from 192 days of Borexino data
We report the direct measurement of the ^7Be solar neutrino signal rate
performed with the Borexino detector at the Laboratori Nazionali del Gran
Sasso. The interaction rate of the 0.862 MeV ^7Be neutrinos is
49+-3(stat)+-4(syst) counts/(day * 100ton). The hypothesis of no oscillation
for ^7Be solar neutrinos is inconsistent with our measurement at the 4sigma
level. Our result is the first direct measurement of the survival probability
for solar nu_e in the transition region between matter-enhanced and
vacuum-driven oscillations. The measurement improves the experimental
determination of the flux of ^7Be, pp, and CNO solar nu_e, and the limit on the
magnetic moment of neutrinos
The Borexino detector at the Laboratori Nazionali del Gran Sasso
Borexino, a large volume detector for low energy neutrino spectroscopy, is
currently running underground at the Laboratori Nazionali del Gran Sasso,
Italy. The main goal of the experiment is the real-time measurement of sub MeV
solar neutrinos, and particularly of the mono energetic (862 keV) Be7 electron
capture neutrinos, via neutrino-electron scattering in an ultra-pure liquid
scintillator. This paper is mostly devoted to the description of the detector
structure, the photomultipliers, the electronics, and the trigger and
calibration systems. The real performance of the detector, which always meets,
and sometimes exceeds, design expectations, is also shown. Some important
aspects of the Borexino project, i.e. the fluid handling plants, the
purification techniques and the filling procedures, are not covered in this
paper and are, or will be, published elsewhere (see Introduction and
Bibliography).Comment: 37 pages, 43 figures, to be submitted to NI
Spirometric changes in obstructive disease: after all, how much is significant?
OBJECTIVE: To establish the upper limits for changes in FEV1, slow vital capacity (SVC), FVC, and inspiratory capacity (IC) after placebo administration in patients with airflow obstruction. METHODS: One hundred and two adults with airflow obstruction (FEV1 = 62 ± 19% of predicted) were included in the study. All of the participants performed SVC and FVC maneuvers before and after the administration of placebo spray. The changes in FEV1, SVC, FVC, and IC were expressed as absolute values, percentage of change from baseline values, and percentage of predicted values, 95% CIs and 95th percentiles being calculated. Factor analysis was performed in order to determine how those changes clustered. RESULTS: Considering the 95% CIs and 95th percentiles and after rounding the values, we found that the upper limits for a significant response were as follows: FEV1 = 0.20 L, FVC = 0.20 L, SVC = 0.25 L, and IC = 0.30 L (expressed as absolute values); FEV1 = 12%, FVC = 7%, SVC = 10%, and IC = 15% (expressed as percentage of change from baseline values); and FEV1 = 7%, FVC = 6%, SVC = 7%, and IC = 12% (expressed as percentage of predicted values). CONCLUSIONS: In patients with airflow obstruction, IC varies more widely than do FVC and SVC. For IC, values greater than 0.30 L and 15% of change from the baseline value can be considered significant. For FVC, values greater than 0.20 L and 7% of change from the baseline value are significant. Alternatively, changes exceeding 0.20 L and 7% of the predicted value can be considered significant for FEV1 and FVC. On factor analysis, spirometric parameters clustered into three dimensions, expressing changes in flows, volumes, and dynamic hyperinflation.OBJETIVO: Estabelecer os limites superiores para mudanças em VEF1, capacidade vital lenta (CVL), CVF e capacidade inspiratória (CI) após o uso de placebo em pacientes com obstrução ao fluxo aéreo. MÉTODOS: Cento e dois adultos com obstrução ao fluxo aéreo (VEF1 = 62 ± 19% do previsto) foram incluídos neste estudo. Todos os participantes realizaram manobras de CVL e CVF antes e depois do uso de spray de placebo. As mudanças em VEF1, CVL, CVF e CI foram expressas em valores absolutos, porcentagem de variação em relação aos valores basais e porcentagem dos valores previstos, e foram calculados os IC95% e os percentis 95. A análise fatorial foi realizada a fim de determinar como essas alterações se agrupavam. RESULTADOS: Considerando os IC95% e percentis 95 e após o arredondamento dos valores, obtivemos os seguintes limites superiores para resposta significante: VEF1 = 0,20 L, CVF = 0,20 L, CVL = 0,25 L e CI = 0,30 L (em valores absolutos); VEF1 = 12%, CVF = 7%, CVL = 10% e CI = 15% (em porcentagem de variação em relação aos valores basais) e VEF1 = 7%, CVF = 6%, CVL = 7% e CI = 12% (em porcentagem dos valores previstos). CONCLUSÕES: Em pacientes com obstrução ao fluxo aéreo, a CI apresenta maior variabilidade do que a CVF e a CVL. Para a CI, valores maiores que 0,30 L e 15% de variação em relação ao valor basal devem ser considerados significantes. Para CVF, valores maiores que 0,20L e 7% de variação em relação ao valor basal são significantes. Alternativamente, alterações de mais de 0,20 L e 7% do previsto no VEF1 e na CVF devem ser consideradas significantes. Na análise fatorial, os parâmetros espirométricos se agruparam em três dimensões, expressando mudanças no fluxo, volume e hiperinsuflação dinâmica.Universidade Federal do Rio Grande do NorteUniversidade Federal de São Paulo (UNIFESP)Hospital do Servidor Público Estadual de São PauloUNIFESPSciEL
- …