11 research outputs found

    Friction and Wear Properties of Si-containing H-free Amorphous Carbon-based Films

    No full text
    To investigate the effect of Si incorporation on friction and wear properties of H-free amorphous carbon-based films, Si-containing H-free amorphous carbon films were deposited on Si and 304 stainless steel substrates by direct current magnetron sputtering method. The composition, structure and mechanical properties of the films were examined by scanning electron microscopy (SEM), Raman spectra, nanoindenter and other techniques. The tribological properties of the films were tested in dry contact conditions using a reciprocating sliding tribometer with ball-on-disk contact geometry. The results indicate that Si incorporation reduces the residual stress of films and promotes the sp~3 hybridization. The film hardness is increased by Si incorporation over 10%. The addition of Si has little influence on friction coefficient of H-free carbon film under various wetting conditions. Si-doped films show higher wear rates than the H-free film, and their wear rates increase with increasing Si contents and decreasing relative humidity. High Si content within films causes significant instability of friction coefficient and leads to severe wear of the films in the low humid air. This suggests that the degradation in performance resulting from Si doping should be fully considered in designing and developing H-free amorphous carbon-based tribological coatings with excellent properties

    Magnetic Lateral Flow Strip for the Detection of Cocaine in Urine by Naked Eyes and Smart Phone Camera

    No full text
    Magnetic lateral flow strip (MLFS) based on magnetic bead (MB) and smart phone camera has been developed for quantitative detection of cocaine (CC) in urine samples. CC and CC-bovine serum albumin (CC-BSA) could competitively react with MB-antibody (MB-Ab) of CC on the surface of test line of MLFS. The color of MB-Ab conjugate on the test line relates to the concentration of target in the competition immunoassay format, which can be used as a visual signal. Furthermore, the color density of the MB-Ab conjugate can be transferred into digital signal (gray value) by a smart phone, which can be used as a quantitative signal. The linear detection range for CC is 5–500 ng/mL and the relative standard deviations are under 10%. The visual limit of detection was 5 ng/mL and the whole analysis time was within 10 min. The MLFS has been successfully employed for the detection of CC in urine samples without sample pre-treatment and the result is also agreed to that of enzyme-linked immunosorbent assay (ELISA). With the popularization of smart phone cameras, the MLFS has large potential in the detection of drug residues in virtue of its stability, speediness, and low-cost

    Prognostic Significance of CD56 Antigen Expression in Patients with De Novo Non-M3 Acute Myeloid Leukemia

    No full text
    Acute myeloid leukemia (AML) is a heterogeneous group of disorders with distinct characteristics and prognoses. Although cytogenetic changes and gene mutations are associated with AML prognosis, there is a need to identify further factors. CD56 is considered a prognostic factor for AML, which is abnormally expressed in leukemia cells. However, a clear consensus for this surface molecule is lacking, which has prompted us to investigate its prognostic significance. Bone marrow samples of de novo non-M3 AML were collected to detect CD56 expression using multiparameter flow cytometry (FCM). As a result, the CD56 expression in de novo non-M3 AML was found to be significantly higher than that in acute lymphoma leukemia (ALL, P=0.017) and healthy controls (P=0.02). The X-Tile program produced a CD56 cutoff point at a relative expression level of 24.62%. Based on this cutoff point, high CD56 expression was observed in 29.21% of de novo non-M3 AML patients. CD56-high patients had a poor overall survival (OS, P=0.015) compared to CD56-low patients. Bone marrow transplantation (BMT) improved OS (P=0.004), but a poor genetic risk was associated with an inferior OS (P=0.002). Compared with CD56-low patients, CD56-high patients had lower peripheral blood platelet (PLT) counts (P=0.010). Our research confirmed that high CD56 expression is associated with adverse clinical outcomes in de novo non-M3 AML patients, indicating that CD56 could be used as a prognostic marker for a more precise stratification of de novo non-M3 AML patients

    Genetic risk of extranodal natural killer T-cell lymphoma: a genome-wide association study in multiple populations

    No full text

    CEPC Conceptual Design Report: Volume 2 - Physics & Detector

    No full text
    The Circular Electron Positron Collider (CEPC) is a large international scientific facility proposed by the Chinese particle physics community to explore the Higgs boson and provide critical tests of the underlying fundamental physics principles of the Standard Model that might reveal new physics. The CEPC, to be hosted in China in a circular underground tunnel of approximately 100 km in circumference, is designed to operate as a Higgs factory producing electron-positron collisions with a center-of-mass energy of 240 GeV. The collider will also operate at around 91.2 GeV, as a Z factory, and at the WW production threshold (around 160 GeV). The CEPC will produce close to one trillion Z bosons, 100 million W bosons and over one million Higgs bosons. The vast amount of bottom quarks, charm quarks and tau-leptons produced in the decays of the Z bosons also makes the CEPC an effective B-factory and tau-charm factory. The CEPC will have two interaction points where two large detectors will be located. This document is the second volume of the CEPC Conceptual Design Report (CDR). It presents the physics case for the CEPC, describes conceptual designs of possible detectors and their technological options, highlights the expected detector and physics performance, and discusses future plans for detector R&D and physics investigations. The final CEPC detectors will be proposed and built by international collaborations but they are likely to be composed of the detector technologies included in the conceptual designs described in this document. A separate volume, Volume I, recently released, describes the design of the CEPC accelerator complex, its associated civil engineering, and strategic alternative scenarios

    CEPC Conceptual Design Report: Volume 2 - Physics & Detector

    No full text
    The Circular Electron Positron Collider (CEPC) is a large international scientific facility proposed by the Chinese particle physics community to explore the Higgs boson and provide critical tests of the underlying fundamental physics principles of the Standard Model that might reveal new physics. The CEPC, to be hosted in China in a circular underground tunnel of approximately 100 km in circumference, is designed to operate as a Higgs factory producing electron-positron collisions with a center-of-mass energy of 240 GeV. The collider will also operate at around 91.2 GeV, as a Z factory, and at the WW production threshold (around 160 GeV). The CEPC will produce close to one trillion Z bosons, 100 million W bosons and over one million Higgs bosons. The vast amount of bottom quarks, charm quarks and tau-leptons produced in the decays of the Z bosons also makes the CEPC an effective B-factory and tau-charm factory. The CEPC will have two interaction points where two large detectors will be located. This document is the second volume of the CEPC Conceptual Design Report (CDR). It presents the physics case for the CEPC, describes conceptual designs of possible detectors and their technological options, highlights the expected detector and physics performance, and discusses future plans for detector R&D and physics investigations. The final CEPC detectors will be proposed and built by international collaborations but they are likely to be composed of the detector technologies included in the conceptual designs described in this document. A separate volume, Volume I, recently released, describes the design of the CEPC accelerator complex, its associated civil engineering, and strategic alternative scenarios
    corecore