429 research outputs found
Presyncopal/Non-Presyncopal Outcomes of Post Spaceflight Stand Tests are Consistent from Flight to Flight
The overall prevalence of orthostatic hypotension after short duration (6-18 d) spaceflight is 20% with existing countermeasures. However, it is not known if the outcomes of stand tests for orthostatic tolerance are consistent within individuals on subsequent flights, or if first time fliers are more (or less) likely to experience orthostatic hypotension and presyncope than are veteran astronauts. Fifty astronauts were studied retrospectively. Stand test data, which had been collected before and after spaceflight, were compared from at least two flights for each astronaut. For twenty-five of these astronauts, their first flight in this database was also their first time to fly into space. For the remaining 25, their first flight in this database was their second, third or fourth flight, as data were available. No subject became presyncopal during preflight testing. Of the 50 subjects, 45 (90%) had the same outcome on their first and second fligh ts of this study. Of 14 subjects on whom we had data from a third mission, 12 had the same stand test outcome on all three flights (86% same outcome across three flights). There was no correlation between flight duration and orthostatic tolerance (r = 0.39). These data support the idea that astronauts are predisposed to orthostatic tolerance/intolerance after spaceflight and that this predisposition is not altered by subsequent flights. Flight durations within this data set did not alter the likelihood of orthostatic intolerance and rookie fliers were no more likely to experience orthostatic intolerance than were veteran astronauts
Evaluations of complex global health initiatives: evidence on the need for case-based research
In My Mercer Racing Car
Illustration of two people driving in a car among tall trees.https://scholarsjunction.msstate.edu/cht-sheet-music/2538/thumbnail.jp
Recommended from our members
The Influence of Composition upon Surface Degradation and Stress Corrosion Cracking of the Ni-Cr-Mo Alloys in Wet Hydrofluoric Acid
At concentrations below 60%, wet hydrofluoric acid (HF) is extremely corrosive to steels, stainless steels and reactive metals, such as titanium, zirconium, and tantalum. In fact, only a few metallic materials will withstand wet HF at temperatures above ambient. Among these are the nickel-copper (Ni-Cu) and nickel-chromium-molybdenum (Ni-Cr-Mo) alloys. Previous work has shown that, even with these materials, there are complicating factors. For example, under certain conditions, internal attack and stress corrosion cracking (SCC) are possible with the Ni-Cr-Mo alloys, and the Ni-Cu materials can suffer intergranular attack when exposed to wet HF vapors. The purpose of this work was to study further the response of the Ni-Cr-Mo alloys to HF, in particular their external corrosion rates, susceptibility to internal attack and susceptibility to HF-induced SCC, as a function of alloy composition. As a side experiment, one of the alloys was tested in two microstructural conditions, i.e. solution annealed (the usual condition for materials of this type) and long-range ordered (this being a means of strengthening the alloy in question). The study of external corrosion rates over wide ranges of concentration and temperature revealed a strong beneficial influence of molybdenum content. However, tungsten, which is used as a partial replacement for molybdenum in some Ni-Cr-Mo alloys, appears to render the alloys more prone to internal attack. With regard to HF-induced SCC of the Ni-Cr-Mo alloys, this study suggests that only certain alloys (i.e., those containing tungsten) exhibit classical SCC. It was also discovered that high external corrosion rates inhibit HF-induced SCC, presumably due to rapid progression of the external attack front. With regard to the effects of long-range ordering, these were only evident at the highest test temperatures, where the ordered structure exhibited much higher external corrosion rates than the annealed structure
Time perception and its neuropsychological correlates in patients with schizophrenia and in healthy volunteers
Disordered time perception has been reported in schizophrenia. We investigated time perception dysfunction and its neuropsychological correlates in patients with schizophrenia. Participants comprised 38 patients and 38 age- and sex-matched healthy volunteers who were compared in an auditory temporal bisection paradigm using two interval ranges (a 400/800 ins condition and a 1000/2000 ms condition). In the temporal bisection, subjects were required to categorise a probe duration as short or long, based upon the similarity with two reference durations. All subjects also completed a battery of neuropsychological tests measuring sustained attention, short- and long-term memory and executive function. In the 400/800 ins condition, patients judged durations significantly shorter than did control subjects. Patients also exhibited decreased temporal sensitivity in both conditions. We found in both groups a negative association between temporal sensitivity and sustained attention for the 400/800 ms condition, and between temporal sensitivity and long-term memory for the 1000/200 ms condition. In patients, short-term memory performance was negatively associated with duration judgement in both conditions, while executive dysfunction was correlated to a general performance deficit in the 400/800 ms condition. These findings suggest the possibility that time perception abnormalities in schizophrenia are part of neuropsychological dysfunction and are likely to adversely impact upon activity of daily living. (c) 2008 Elsevier Ireland Ltd. All rights reserved
ExoPranayama: a biofeedback-driven actuated environment for supporting yoga breathing practices
Both breathing and internal self-awareness are an integral part of any yoga practice. We describe and discuss the development of ExoPranayama, an actuated environment that physically manifests users’ breathing in yoga. Through a series of trials with yoga practitioners and expert teachers, we explore its role in the practice of yoga. Our interview results reveal that biofeedback through the environment supported teaching and improved self-awareness, but it impacted group cohesion. Two practical uses of the technology emerged for supporting breath control in yoga: (1) biofeedback can provide new information about users’ current internal states; (2) machine-driven feedback provides users with a future state or goal, and leads to improved cohesiveness
Cardiovascular Adaptations to Long Duration Head-Down Tilt Bed Rest
INTRODUCTION: Orthostatic hypotension is a serious risk for crewmembers returning from spaceflight. Numerous cardiovascular mechanisms have been proposed to account for this problem, including vascular and cardiac dysfunction, which we studied during bed rest. METHODS: Thirteen subjects were studied before and during bed rest. Statistical analysis was limited to the first 49-60 days of bed rest, and compared to pre-bed rest data. Ultrasound data were collected on vascular and cardiac structure and function. Tilt testing was conducted for 30 minutes or until presyncopal symptoms intervened. RESULTS: Plasma volume was significantly reduced by day 7 of bed rest. Flow-mediated dilation in the leg was significantly increased at bed rest day 49. Arterial responses to nitroglycerin differed in the arm and leg, but did not change as a result of bed rest. Intimal-medial thickness markedly decreased at bed rest days 21, 35 and 49. Several cardiac functional parameters including isovolumic relaxation time, ejection time and myocardial performance index were significantly increased (indicating a decrease in cardiac function) during bed rest. There was a trend for decreased orthostatic tolerance following 60 days of bed rest. DISCUSSION: These data suggest that 6 head-down tilt bed rest alters cardiovascular structure and function in a pattern similar to short duration spaceflight. Additionally, the vascular alterations are primarily seen in the lower body, while vessels of the upper body are unaffected. KEY WORDS: spaceflight, orthostatic intolerance, hypotension, fluid-shift, plasma volum
Relativistic Compression and Expansion of Experiential Time in the Left and Right Space
Time, space and numbers are closely linked in the physical world. However, the relativistic-like effects on time perception of spatial and magnitude factors remain poorly investigated. Here we wanted to investigate whether duration judgments of digit visual stimuli are biased depending on the side of space where the stimuli are presented and on the magnitude of the stimulus itself. Different groups of healthy subjects performed duration judgment tasks on various types of visual stimuli. In the first two experiments visual stimuli were constituted by digit pairs (1 and 9), presented in the centre of the screen or in the right and left space. In a third experiment visual stimuli were constituted by black circles. The duration of the reference stimulus was fixed at 300 ms. Subjects had to indicate the relative duration of the test stimulus compared with the reference one. The main results showed that, regardless of digit magnitude, duration of stimuli presented in the left hemispace is underestimated and that of stimuli presented in the right hemispace is overestimated. On the other hand, in midline position, duration judgments are affected by the numerical magnitude of the presented stimulus, with time underestimation of stimuli of low magnitude and time overestimation of stimuli of high magnitude. These results argue for the presence of strict interactions between space, time and magnitude representation on the human brain
A Neural Correlate of the Processing of Multi-Second Time Intervals in Primate Prefrontal Cortex
Several areas of the brain are known to participate in temporal processing.
Neurons in the prefrontal cortex (PFC) are thought to contribute to perception
of time intervals. However, it remains unclear whether the PFC itself can
generate time intervals independently of external stimuli. Here we describe a
group of PFC neurons in area 9 that became active when monkeys recognized a
particular elapsed time within the range of 1–7 seconds. Another group of
area 9 neurons became active only when subjects reproduced a specific interval
without external cues. Both types of neurons were individually tuned to
recognize or reproduce particular intervals. Moreover, the injection of
muscimol, a GABA agonist, into this area bilaterally resulted in an increase in
the error rate during time interval reproduction. These results suggest that
area 9 may process multi-second intervals not only in perceptual recognition,
but also in internal generation of time intervals
Attenuation of the effects of d-amphetamine on interval timing behavior by central 5-hydroxytryptamine depletion
- …