298 research outputs found

    Лечение переломов дистального метаэпифиза лучевой кости с использованием малоинвазивного накостного остеосинтеза и перкутанной спицевой фиксации: сравнительный анализ результатов анализ результатов

    Get PDF
    Purpose to evaluate and to compare radiological and functional outcomes of the volar locking plate fixation using pronator-sparing approach and K-wire fixation of distal radius fractures. Materials and Methods. We retrospectively analyzed 41 patients with distal radius fractures (27 female and 14 male) treated in the period from 2016 to 2020 using minimally invasive osteosynthesis via pronator-sparing approach. The mean age was 51 years (31-74 years). The control group consists of 37 patients (19 female and 18 male, mean age 61 years (29-76 years)), who underwent minimally invasive percutaneous K-wire fixation of distal radius fractures during the same period of time. Comparative analysis of radiographic and functional outcomes in both groups of minimally invasive osteosynthesis of distal radius fractures was carried out in the period from 1 to 6 months after the surgery. Results. Primary union of distal radius fractures was confirmed in X-rays in all patients within 6 weeks after the surgery. There were no complications in patients treated by pronator-sparing volar locking plate fixation, whereas in K-wire group we had 6 patients with complications: 4 cases (11%) superficial infection around K-wires and 2 cases (5,4%) intraoperative damage of sensitive branch of radial nerve. There were statistically significant differences in radiographic results (volar tilt, radial inclination, and radial height) between two groups: they all were better in patients treated by pronator-sparing volar locking plate fixation during the whole follow-up period (р0,01). Minimally invasive volar locking plate fixation via pronator-sparing approach also provided significantly better grip strength and range of wrist motion and forearm rotation in the early 6-month postoperative period, compared with percutaneous K-wire fixation (р0,001). Conclusion. Our study demonstrates that both techniques of minimally invasive osteosynthesis of distal radius fractures are effective and relatively safe methods of surgical treatment, but volar plating via pronator-sparing approach leads to a better reconstruction of the distal radius and better functional outcomes compared to percutaneous K-wiring.Цель исследования сравнительная оценка рентгенологических и функциональных результатов малоинвазивного накостного остеосинтеза с применением пронатор-сберегающего доступа и перкутанной спицевой фиксации у пациентов с переломами дистального метаэпифиза лучевой кости (ДМЛК). Материал и методы. Проведен ретроспективный анализ результатов лечения 41 пациента с переломами ДМЛК (14 мужчин и 27 женщин), которым в период с 2016 по 2020 г. был выполнен малоинвазивный накостный остеосинтез блокируемыми пластинами с применением пронатор-сберегающего хирургического доступа (основная группа). Средний возраст больных составил 51 год (от 31 до 74 лет). В контрольную группу вошли 37 пациентов: 19 женщин и 18 мужчин; средний возраст 61 год (от 29 до 76 лет), которым за этот же период времени был выполнен малоинвазивный перкутанный спицевой остеосинтез ДМЛК. Сравнительную оценку рентгенологических и функциональных результатов малоинвазивного остеосинтеза в обеих группах осуществляли в сроки от 1 до 6 мес. со дня оперативного лечения. Результаты. У всех пациентов в сроки до 6 нед. после операции была достигнута консолидация переломов, подтвержденная рентгенологически. Среди пациентов, прооперированных путем пронатор-сберегающего накостного остеосинтеза, осложнений не было, в группе пациентов, которым выполняли перкутанный спицевой остеосинтез, было получено 6 осложнений: в 4 случаях (11%) воспаление в области выхода спиц и в 2 случаях (5,4%) ятрогенное интраоперационное повреждение чувствительной ветви лучевого нерва. Были получены статистически значимые различия в рентгенологических результатах (ладонный наклон суставной фасетки лучевой кости, инклинация лучевой кости и высота лучевой кости) между двумя группами. Показатели в основной группе пациентов были лучше на всех этапах наблюдения (p0,01). Малоинвазивный накостный остеосинтез с применением пронатор-сберегающей техники также продемонстрировал значимо лучшие функциональные результаты (сила схвата кисти, объем движения в лучезапястном суставе, ротационные движения предплечья) по сравнению с контрольной группой на всех этапах оценки (p0,001). Заключение. Результаты исследования демонстрируют эффективность и относительную безопасность обеих методик малоинвазивного остеосинтеза ДМЛК. Однако накостный остеосинтез волярными блокируемыми пластинами с применением пронатор-сберегающей техники позволяет получать лучшие рентгенологические и функциональные результаты по сравнению с применением чрескожного остеосинтеза спицами

    Overcritical states of a superconductor strip in a magnetic environment

    Full text link
    A current-carrying superconducting strip partly penetrated by magnetic flux and surrounded by a bulk magnet of high permeability is considered. Two types of samples are studied: those with critical current controlled by an edge barrier dominating over the pinning, and those with high pinning-mediated critical current masking the edge barrier.It is shown for both cases that the current distribution in a central flux-free part of the strip is strongly affected by the actual shape of the magnetic surroundings. Explicit analytical solutions for the sheet current and self-field distributions are obtained which show that, depending on the geometry, the effect may suppress the total loss-free transport current of the strip or enhance it by orders of magnitude. The effect depends strongly on the shape of the magnet and its distance to the superconductor but only weakly on the magnetic permeability.Comment: 20 pages, 20 figure

    Gluon polarization in the nucleon from quasi-real photoproduction of high-pT hadron pairs

    Get PDF
    We present a determination of the gluon polarization Delta G/G in the nucleon, based on the helicity asymmetry of quasi-real photoproduction events, Q^2<1(GeV/c)^2, with a pair of large transverse-momentum hadrons in the final state. The data were obtained by the COMPASS experiment at CERN using a 160 GeV polarized muon beam scattered on a polarized 6-LiD target. The helicity asymmetry for the selected events is = 0.002 +- 0.019(stat.) +- 0.003(syst.). From this value, we obtain in a leading-order QCD analysis Delta G/G=0.024 +- 0.089(stat.) +- 0.057(syst.) at x_g = 0.095 and mu^2 =~ 3 (GeV}/c)^2.Comment: 10 pages, 3 figure

    The Deuteron Spin-dependent Structure Function g1d and its First Moment

    Get PDF
    We present a measurement of the deuteron spin-dependent structure function g1d based on the data collected by the COMPASS experiment at CERN during the years 2002-2004. The data provide an accurate evaluation for Gamma_1^d, the first moment of g1d(x), and for the matrix element of the singlet axial current, a0. The results of QCD fits in the next to leading order (NLO) on all g1 deep inelastic scattering data are also presented. They provide two solutions with the gluon spin distribution function Delta G positive or negative, which describe the data equally well. In both cases, at Q^2 = 3 (GeV/c)^2 the first moment of Delta G is found to be of the order of 0.2 - 0.3 in absolute value.Comment: fits redone using MRST2004 instead of MRSV1998 for G(x), correlation matrix adde

    Spin asymmetry A_1^d and the spin-dependent structure function g_1^d of the deuteron at low values of x and Q^2

    Get PDF
    We present a precise measurement of the deuteron longitudinal spin asymmetry A_1^d and of the deuteron spin-dependent structure function g_1^d at Q^2 < 1 GeV^2 and 4*10^-5 < x < 2.5*10^-2 based on the data collected by the COMPASS experiment at CERN during the years 2002 and 2003. The statistical precision is tenfold better than that of the previous measurement in this region. The measured A_1^d and g_1^d are found to be consistent with zero in the whole range of x.Comment: 17 pages, 10 figure

    A new measurement of the Collins and Sivers asymmetries on a transversely polarised deuteron target

    Get PDF
    New high precision measurements of the Collins and Sivers asymmetries of charged hadrons produced in deep-inelastic scattering of muons on a transversely polarised 6LiD target are presented. The data were taken in 2003 and 2004 with the COMPASS spectrometer using the muon beam of the CERN SPS at 160 GeV/c. Both the Collins and Sivers asymmetries turn out to be compatible with zero, within the present statistical errors, which are more than a factor of 2 smaller than those of the published COMPASS results from the 2002 data. The final results from the 2002, 2003 and 2004 runs are compared with naive expectations and with existing model calculations.Comment: 40 pages, 28 figure

    Measurement of the Spin Structure of the Deuteron in the DIS Region

    Full text link
    We present a new measurement of the longitudinal spin asymmetry A_1^d and the spin-dependent structure function g_1^d of the deuteron in the range 1 GeV^2 < Q^2 < 100 GeV^2 and 0.004< x <0.7. The data were obtained by the COMPASS experiment at CERN using a 160 GeV polarised muon beam and a large polarised 6-LiD target. The results are in agreement with those from previous experiments and improve considerably the statistical accuracy in the region 0.004 < x < 0.03.Comment: 10 pages, 6 figures, subm. to PLB, revised: author list, Fig. 4, details adde

    The COMPASS Experiment at CERN

    Get PDF
    The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both hadron and electromagnetic calorimeters. The setup has been successfully operated from 2002 onwards using a muon beam. Data with a hadron beam were also collected in 2004. This article describes the main features and performances of the spectrometer in 2004; a short summary of the 2006 upgrade is also given.Comment: 84 papes, 74 figure

    Electron accelerator for energy up to 5.0 MeV and beam power up to 50 kW with Х-ray converter

    No full text
    The paper describes the industrial electron accelerator ILU-10 for electron energy up to 5 MeV and beam power up to 50 kW specially designed for use in industrial applications. The ILU-10 accelerator generates the vertical electron beam. The beam line turns the beam through an angle of 90° and transports the beam to the vertically posed Xray converter to generate the horizontal beam of X-rays.Приводиться опис прискорювача електронів ІЛУ-10 на енергію 5 МеВ потужністю 50 кВт, спеціально розробленого для таких комплексів. Для спрощення конструкції конвеєрної системи подачі оброблюваної продукції в зону опромінення використовується випускний пристрій з поворотом пучка на 90 градусів інаступною конвертацією електронного пучка в гамма-випромінювання на вертикально розташованій мішені.Приводится описание ускорителя электронов ИЛУ-10 на энергию 5 МэВ мощностью 50 кВт, специально разработанного для таких комплексов. Для упрощения конструкции конвейерной системы подачи обрабатываемой продукции в зону облучения используется выпускное устройство с поворотом пучка на 90 градусов и последующей конвертацией электронного пучка в гамма-излучение на вертикально расположенной мишени
    corecore