442 research outputs found
On-site forest fire smoke detection by low-power autonomous vision sensor
Trabajo presentado a la VI International Conference on Forest Fire Research celebrada en Coimbra (Portugal) del 15 al 18 de noviembre de 2010.Early detection plays a crucial role to prevent forest fires from spreading. Wireless vision sensor networks deployed throughout high-risk areas can perform fine-grained surveillance and thereby very early detection and precise location of forest fires. One of the fundamental requirements that need to be met at the network nodes is reliable low-power on-site image processing. It greatly simplifies the communication infrastructure of the network as only alarm signals instead of complete images are transmitted, anticipating thus a very competitive cost. As a first approximation to fulfill such a requirement, this paper reports the results achieved from field tests carried out in collaboration with the Andalusian Fire-Fighting Service (INFOCA). Two controlled burns of forest debris were realized (www.youtube.com/user/vmoteProject). Smoke was successfully detected on-site by the EyeRISTM v1.2, a general-purpose autonomous vision system, built by AnaFocus Ltd., in which a vision algorithm was programmed. No false alarm was triggered despite the significant motion other than smoke present in the scene. Finally, as a further step, we describe the preliminary laboratory results obtained from a prototype vision chip which implements, at very low energy cost, some image processing primitives oriented to environmental monitoring.This work is funded by CICE/JA and MICINN (Spain) through projects 2006-TIC-2352 and TEC2009-11812 respectively.Peer Reviewe
Morphometric study of the nerve fibers of the oculomotor nerve in dog
The intracranial portion of the right oculomotor nerves was extracted from six adult German Shepherd dogs. The nerves were studied using light
and electron microscopy. Nerve area was calculated, and myelinated and unmyelinated fibers were analized to determine number, diameter and area.
Also in the myelinated fibers the area and diameter of the correspondent axon, and thickness of the myeline sheath were measured. The mean
number of fibers was 8543.50±1231.85 for myelinated and 1402.00±241.58 for unmyelinated. The mean fiber diameter was 10.23±0.68 μm for
myelinated and 0.43±0.21 μm for unmyelinated. This study demonstrated that the oculomotor nerves in dogs have structural and ultrastructural
characteristics that are similar to those from other specie
Intravenous immunoglobulin to prevent myasthenic crisis after thymectomy and other procedures can be omitted in patients with well-controlled myasthenia gravis
Immunoglobulin; Myasthenia; ThymectomyInmunoglobulina; Miastenia; TimectomíaImmunoglobulina; Miastènia; TimectomiaBACKGROUND:
Myasthenic crisis (MC) is a potentially life-threatening complication of myasthenia gravis. Its precipitating factors include surgical procedures, particularly thymectomy. The role of preoperative intravenous immunoglobulin (IVIg) in preventing MC in patients scheduled for thymectomy and other surgery with general anaesthesia is unknown. Our objective was to test the hypothesis that preoperative IVIg is effective in preventing myasthenic crisis in patients with myasthenia gravis scheduled for surgery under general anaesthesia, including thymectomy.
METHODS:
A prospective, randomized, double-blind, single-centre study was conducted over a 4-year period. The treatment group received IVIg, 0.4 g/kg/day preoperatively for 5 consecutive days, and the placebo group received saline solution under the same conditions. The two groups were age-matched, with similar functional status, and Myasthenia Gravis Foundation of America class. All patients had well-controlled myasthenia gravis with minimal manifestations before surgery. The primary outcome measured was MC. Intubation times, time in the recovery room, number of postoperative complications, and days of hospitalization were the secondary outcomes measured.
RESULTS:
A total of 47 patients were randomized, 25 to the IVIg group and 22 to placebo. There were 19 men and 28 women, with a mean age of 58.6 years, mean body mass index of 27.8 kg/m2, and mean acetylcholine receptor antibodies of 12.9 nmol/l. The mean forced vital capacity was 84.4%. The mean quantitative myasthenia gravis sum score was 6.3. Ten patients (five in each arm) had a history of MC. Thymectomy was performed in 16 patients. Only one patient in the placebo group presented with MC requiring non-invasive ventilation (but no reintubation) for 6 days. Neither differences between groups in the univariate analysis nor risk factors for MC in the multivariate analysis were found.
CONCLUSIONS:
Preoperative IVIg to prevent MC does not appear to be justified in well-controlled myasthenia gravis patients. This study provides class I evidence that preparation with IVIg to prevent MC is not necessary in well-controlled myasthenia gravis patients scheduled for surgery with general anaesthesia.This work was funded by a Fondo de Investigacion Sanitaria (FIS-FEDER) (grants PI16-01673 and PI19/00593) and an Interlaken Research Award Programme (2012-12094537
Intravenous immunoglobulin to prevent myasthenic crisis after thymectomy and other procedures can be omitted in patients with well-controlled myasthenia gravis
The authors disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was funded by a Fondo de Investigación Sanitaria (FIS-FEDER) (grants PI16-01673 and PI19/00593) and an Interlaken Research Award Programme (2012-12094537).Background: Myasthenic crisis (MC) is a potentially life-threatening complication of myasthenia gravis. Its precipitating factors include surgical procedures, particularly thymectomy. The role of preoperative intravenous immunoglobulin (IVIg) in preventing MC in patients scheduled for thymectomy and other surgery with general anaesthesia is unknown. Our objective was to test the hypothesis that preoperative IVIg is effective in preventing myasthenic crisis in patients with myasthenia gravis scheduled for surgery under general anaesthesia, including thymectomy. Methods: A prospective, randomized, double-blind, single-centre study was conducted over a 4-year period. The treatment group received IVIg, 0.4 g/kg/day preoperatively for 5 consecutive days, and the placebo group received saline solution under the same conditions. The two groups were age-matched, with similar functional status, and Myasthenia Gravis Foundation of America class. All patients had well-controlled myasthenia gravis with minimal manifestations before surgery. The primary outcome measured was MC. Intubation times, time in the recovery room, number of postoperative complications, and days of hospitalization were the secondary outcomes measured. Results: A total of 47 patients were randomized, 25 to the IVIg group and 22 to placebo. There were 19 men and 28 women, with a mean age of 58.6 years, mean body mass index of 27.8 kg/m, and mean acetylcholine receptor antibodies of 12.9 nmol/l. The mean forced vital capacity was 84.4%. The mean quantitative myasthenia gravis sum score was 6.3. Ten patients (five in each arm) had a history of MC. Thymectomy was performed in 16 patients. Only one patient in the placebo group presented with MC requiring non-invasive ventilation (but no reintubation) for 6 days. Neither differences between groups in the univariate analysis nor risk factors for MC in the multivariate analysis were found. Conclusions: Preoperative IVIg to prevent MC does not appear to be justified in well-controlled myasthenia gravis patients. This study provides class I evidence that preparation with IVIg to prevent MC is not necessary in well-controlled myasthenia gravis patients scheduled for surgery with general anaesthesia
A new method to quantify and compare the multiple components of fitness-A study case with kelp niche partition by divergent microstage adaptations to Temperature
Point 1 Management of crops, commercialized or protected species, plagues or life-cycle evolution are subjects requiring comparisons among different demographic strategies. The simpler methods fail in relating changes in vital rates with changes in population viability whereas more complex methods lack accuracy by neglecting interactions among vital rates. Point 2 The difference between the fitness (evaluated by the population growth rate.) of two alternative demographies is decomposed into the contributions of the differences between the pair-wised vital rates and their interactions. This is achieved through a full Taylor expansion (i.e. remainder = 0) of the demographic model. The significance of each term is determined by permutation tests under the null hypothesis that all demographies come from the same pool. Point 3 An example is given with periodic demographic matrices of the microscopic haploid phase of two kelp cryptic species observed to partition their niche occupation along the Chilean coast. The method provided clear and synthetic results showing conditional differentiation of reproduction is an important driver for their differences in fitness along the latitudinal temperature gradient. But it also demonstrated that interactions among vital rates cannot be neglected as they compose a significant part of the differences between demographies. Point 4 This method allows researchers to access the effects of multiple effective changes in a life-cycle from only two experiments. Evolutionists can determine with confidence the effective causes for changes in fitness whereas population managers can determine best strategies from simpler experimental designs.CONICYT-FRENCH EMBASSADY Ph.D. gran
NEXT-100 Technical Design Report (TDR). Executive Summary
In this Technical Design Report (TDR) we describe the NEXT-100 detector that
will search for neutrinoless double beta decay (bbonu) in Xe-136 at the
Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes
the design presented in our Conceptual Design Report (CDR): an
electroluminescence time projection chamber, with separate readout planes for
calorimetry and tracking, located, respectively, behind cathode and anode. The
detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or
100 kg at 10 bar. This option builds in the capability to increase the total
isotope mass by 50% while keeping the operating pressure at a manageable level.
The readout plane performing the energy measurement is composed of Hamamatsu
R11410-10 photomultipliers, specially designed for operation in low-background,
xenon-based detectors. Each individual PMT will be isolated from the gas by an
individual, pressure resistant enclosure and will be coupled to the sensitive
volume through a sapphire window. The tracking plane consists in an array of
Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged
in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner
walls of the TPC, the sapphire windows and the boards holding the MPPCs will be
coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the
light collection.Comment: 32 pages, 22 figures, 5 table
Epigenetics in schizophrenia: a pilot study of global DNA methylation in different brain regions associated with higher cognitive functions
Attempts to discover genes that are involved in the pathogenesis of major psychiatric disorders have been frustrating and often fruitless. Concern is building about the need to understand the complex ways in which nature and nurture interact to produce mental illness. We analyze the epigenome in several brain regions from schizophrenic patients with severe cognitive impairment using high-resolution (450K) DNA methylation array. We identified 139 differentially methylated CpG sites included in known and novel candidate genes sequences as well as in and intergenic sequences which functions remain unknown. We found that altered DNA methylation is not restricted to a particular region, but includes others such as CpG shelves and gene bodies, indicating the presence of different DNA methylation signatures depending on the brain area analyzed. Our findings suggest that epimutations are not relatables between different tissues or even between tissues' regions, highlighting the need to adequately study brain samples to obtain reliable data concerning the epigenetics of schizophrenia
Measurement of Through-Going Particle Momentum By Means Of Multiple Scattering With The ICARUS T600 TPC
The ICARUS collaboration has demonstrated, following the operation of a 600
ton (T600) detector at shallow depth, that the technique based on liquid Argon
TPCs is now mature. The study of rare events, not contemplated in the Standard
Model, can greatly benefit from the use of this kind of detectors. In
particular, a deeper understanding of atmospheric neutrino properties will be
obtained thanks to the unprecedented quality of the data ICARUS provides.
However if we concentrate on the T600 performance, most of the
charged current sample will be partially contained, due to the reduced
dimensions of the detector. In this article, we address the problem of how well
we can determine the kinematics of events having partially contained tracks.
The analysis of a large sample of atmospheric muons collected during the T600
test run demonstrate that, in case the recorded track is at least one meter
long, the muon momentum can be reconstructed by an algorithm that measures the
Multiple Coulomb Scattering along the particle's path. Moreover, we show that
momentum resolution can be improved by a factor two using an algorithm based on
the Kalman Filtering technique
Systematic search for VHE gamma-ray emission from X-ray bright high-frequency BL Lac objects
All but three (M87, BL Lac and 3C 279) extragalactic sources detected so far
at very high energy (VHE) gamma-rays belong to the class of high-frequency
peaked BL Lac (HBL) objects. This suggested to us a systematic scan of
candidate sources with the MAGIC telescope, based on the compilation of X-ray
blazars by Donato et al. (2001). The observations took place from December 2004
to March 2006 and cover sources on the northern sky visible under small zenith
distances zd < 30 degrees at culmination. The sensitivity of the search was
planned for detecting X-ray bright F(1 keV) > 2 uJy) sources emitting at least
the same energy flux at 200 GeV as at 1 keV. In order to avoid strong gamma-ray
attenuation close to the energy threshold, the redshift of the sources was
constrained to values z<0.3. Of the fourteen sources observed, 1ES 1218+304 and
1ES 2344+514 have been detected in addition to the known bright TeV blazars Mrk
421 and Mrk 501. A marginal excess of 3.5 sigma from the position of 1ES
1011+496 was observed and has been confirmed as a source of VHE gamma-rays by a
second MAGIC observation triggered by a high optical state (Albert et al.
2007). For the remaining sources, we present here the 99% confidence level
upper limits on the integral flux above ~200 GeV. We characterize the sample of
HBLs (including all HBLs detected at VHE so far) by looking for correlations
between their multi-frequency spectral indices determined from simultaneous
optical, archival X-ray, and radio luminosities, finding that the VHE emitting
HBLs do not seem to constitute a unique subclass. The absorption corrected
gamma-ray luminosities at 200 GeV of the HBLs are generally not higher than
their X-ray luminosities at 1 keV.Comment: 15 pages, 7 figures, 5 tables, submitted to ApJ (revised version
- …