3D electronics for hybrid pixel detectors – TWEPP-09
Future hybrid pixel detectors are asking for smaller pixels in order to improve spatial resolution and to deal with an increasing counting rate. Facing these requirements is foreseen to be done by microelectronics technology shrinking. However, this straightforward approach presents some disadvantages in term of performances and cost. New 3D technologies offer an alternative way with the advantage of technology mixing. For the upgrade of ATLAS pixel detector, a 3D conception of the read-out chip appeared as an interesting solution. Splitting the pixel functionalities into two separate levels will reduce pixel size and open the opportunity to take benefit of technology's mixing. Based on a previous prototype of the read-out chip FE-I4 (IBM 130nm), this paper presents the design of a hybrid pixel read-out chip using threedimensional Tezzaron-Chartered technology. In order to disentangle effects due to Chartered 130nm technology from effects involved by 3D architecture, a first translation of FEI4 prototype had been designed at the beginning of this year in Chartered 2D technology, and first test results will be presented in the last part of this paper
HV/HR-CMOS sensors for the ATLAS upgrade—concepts and test chip results
In order to extend its discovery potential, the Large Hadron Collider (LHC) will have a major upgrade (Phase II Upgrade) scheduled for 2022. The LHC after the upgrade, called High-Luminosity LHC (HL-LHC), will operate at a nominal leveled instantaneous luminosity of 5× 1034 cm−2 s−1, more than twice the expected Phase I . The new Inner Tracker needs to cope with this extremely high luminosity. Therefore it requires higher granularity, reduced material budget and increased radiation hardness of all components. A new pixel detector based on High Voltage CMOS (HVCMOS) technology targeting the upgraded ATLAS pixel detector is under study. The main advantages of the HVCMOS technology are its potential for low material budget, use of possible cheaper interconnection technologies, reduced pixel size and lower cost with respect to traditional hybrid pixel detector. Several first prototypes were produced and characterized within ATLAS upgrade R&D effort, to explore the performance and radiation hardness of this technology.
In this paper, an overview of the HVCMOS sensor concepts is given. Laboratory tests and irradiation tests of two technologies, HVCMOS AMS and HVCMOS GF, are also given
Radiation-hard active pixel sensors for HL-LHC detector upgrades based on HV-CMOS technology
Luminosity upgrades are discussed for the LHC (HL-LHC) which would make updates to the detectors necessary, requiring in particular new, even more radiation-hard and granular, sensors for the inner detector region.
A proposal for the next generation of inner detectors is based on HV-CMOS: a new family of silicon sensors based on commercial high-voltage CMOS technology, which enables the fabrication of part of the pixel electronics inside the silicon substrate itself.
The main advantages of this technology with respect to the standard silicon sensor technology are: low material budget, fast charge collection time, high radiation tolerance, low cost and operation at room temperature.
A traditional readout chip is still needed to receive and organize the data from the active sensor and to handle high-level functionality such as trigger management. HV-CMOS has been designed to be compatible with both pixel and strip readout.
In this paper an overview of HV2FEI4, a HV-CMOS prototype in 180 nm AMS technology, will be given. Preliminary results after neutron and X-ray irradiation are shown
Airway structural cells regulate TLR5-mediated mucosal adjuvant activity
Antigen-presenting cell (APC) activation is enhanced by vaccine adjuvants. Most vaccines are based on the assumption that adjuvant activity of Toll-like receptor (TLR) agonists depends on direct, functional activation of APCs. Here, we sought to establish whether TLR stimulation in non-hematopoietic cells contributes to flagellin’s mucosal adjuvant activity. Nasal administration of flagellin enhanced T-cell-mediated immunity, and systemic and secretory antibody responses to coadministered antigens in a TLR5-dependent manner. Mucosal adjuvant activity was not affected by either abrogation of TLR5 signaling in hematopoietic cells or the presence of flagellin-specific, circulating neutralizing antibodies. We found that flagellin is rapidly degraded in conducting airways, does not translocate into lung parenchyma and stimulates an early immune response, suggesting that TLR5 signaling is regionalized. The flagellin-specific early response of lung was regulated by radioresistant cells expressing TLR5 (particularly the airway epithelial cells). Flagellin stimulated the epithelial production of a small set of mediators that included the chemokine CCL20, which is known to promote APC recruitment in mucosal tissues. Our data suggest that (i) the adjuvant activity of TLR agonists in mucosal vaccination may require TLR stimulation of structural cells and (ii) harnessing the effect of adjuvants on epithelial cells can improve mucosal vaccines.Fil: Van Maele, Laurye. Institut Pasteur de Lille. Lille; Francia. Univ Lille Nord de France. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; FranciaFil: Fougeron, Delphine. Institut Pasteur de Lille. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Univ Lille Nord de France. Lille; FranciaFil: Janot, Laurent. University of Orléans. Orléans; Francia. Institut de Transgenose. Orleans; FranciaFil: Didierlaurent, A.. Imperial College of London. Londres; Reino UnidoFil: Cayet, D.. Institut Pasteur de Lille. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Univ Lille Nord de France. Lille; FranciaFil: Tabareau, J.. Institut Pasteur de Lille. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Univ Lille Nord de France. Lille; FranciaFil: Rumbo, Martín. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Estudios Inmunológicos y Fisiopatológicos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Estudios Inmunológicos y Fisiopatológicos; ArgentinaFil: Corvo Chamaillard, S.. Institut Pasteur de Lille. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Univ Lille Nord de France. Lille; FranciaFil: Boulenoir, S.. Institut Pasteur de Lille. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Univ Lille Nord de France. Lille; FranciaFil: Jeffs, S. Imperial College of London. Londres; Reino UnidoFil: Vande Walle, L. Department of Medical Protein Research. Ghent; Bélgica. University of Ghent; BélgicaFil: Lamkanfi, M.. Department of Medical Protein Research. Ghent; Bélgica. University of Ghent; BélgicaFil: Lemoine, Y.. Univ Lille Nord de France. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Institut Pasteur de Lille. Lille; FranciaFil: Erard, F.. Institut de Transgenose. Orleans; Francia. University of Orléans. Orléans; FranciaFil: Hot, D.. Univ Lille Nord de France. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Institut Pasteur de Lille. Lille; FranciaFil: Hussell, Tracy. Imperial College of London. Londres; Reino Unido. University of Manchester; Reino UnidoFil: Ryffel, B.. Institut de Transgenose. Orleans; Francia. University of Orléans. Orléans; FranciaFil: Benecke, Arndt G.. Institut des Hautes Études Scientifiques and Centre National de la Recherche Scientifique; FranciaFil: Sirard, J.C.. Univ Lille Nord de France. Lille; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Institut Pasteur de Lille. Lille; Franci
Prototype ATLAS IBL Modules using the FE-I4A Front-End Readout Chip
The ATLAS Collaboration will upgrade its semiconductor pixel tracking
detector with a new Insertable B-layer (IBL) between the existing pixel
detector and the vacuum pipe of the Large Hadron Collider. The extreme
operating conditions at this location have necessitated the development of new
radiation hard pixel sensor technologies and a new front-end readout chip,
called the FE-I4. Planar pixel sensors and 3D pixel sensors have been
investigated to equip this new pixel layer, and prototype modules using the
FE-I4A have been fabricated and characterized using 120 GeV pions at the CERN
SPS and 4 GeV positrons at DESY, before and after module irradiation. Beam test
results are presented, including charge collection efficiency, tracking
efficiency and charge sharing.Comment: 45 pages, 30 figures, submitted to JINS
Design of analog front-ends for the RD53 demonstrator chip
The RD53 collaboration is developing a large scale pixel front-end chip, which will be a tool to evaluate the performance of 65 nm CMOS technology in view of its application to the readout of the innermost detector layers of ATLAS and CMS at the HL-LHC. Experimental results of the characterization of small prototypes will be discussed in the frame of the design work that is currently leading to the development of the large scale demonstrator chip RD53A to be submitted in early 2017. The paper is focused on the analog processors developed in the framework of the RD53 collaboration, including three time over threshold front-ends, designed by INFN Torino and Pavia, University of Bergamo and LBNL and a zero dead time front-end based on flash ADC designed by a joint collaboration between the Fermilab and INFN. The paper will also discuss the radiation tolerance features of the front-end channels, which were exposed to up to 800 Mrad of total ionizing dose to reproduce the system operation in the actual experiment
The modulation of lexical competition by segment duration
Item does not contain fulltextIn an eye-tracking study, we examined how fine-grained phonetic detail, such as segment duration, influences the lexical competition process during spoken word recognition. Dutch listeners' eye movements to pictures of four objects were monitored as they heard sentences in which a stop-initial target word (e.g., pijp "pipe") was preceded by an [s]. The participants made more fixations to pictures of cluster-initial words (e.g., spijker "nail") when they heard a long [s] (mean duration, 103 msec) than when they heard a short [s] (mean duration, 73 msec). Conversely, the participants made more fixations to pictures of the stop-initial words when they heard a short [s] than when they heard a long [s]. Lexical competition between stop- and cluster-initial words, therefore, is modulated by segment duration differences of only 30 msec.6 p
- …