107 research outputs found

    Defining the role of dexmedetomidine in the prevention of delirium in the intensive care unit (ICU)

    Get PDF
    Dexmedetomidine is a highly selective α2 agonist used as a sedative agent. It also provides anxiolysis and sympatholysis without significant respiratory compromise or delirium. We conducted a systematic review to examine whether sedation of patients in the intensive care unit (ICU) with dexmedetomidine was associated with a lower incidence of delirium as compared to other nondexmedetomidine sedation strategies. A search of PUBMED, EMBASE, and the Cochrane Database of Systematic Reviews yielded only three trials from 1966 through April 2015 that met our predefined inclusion criteria and assessed dexmedetomidine and outcomes of delirium as their primary endpoint. The studies varied in regard to population, comparator sedation regimen, delirium outcome measure, and dexmedetomidine dosing. All trials are limited by design issues that limit our ability definitively to conclude that dexmedetomidine prevents delirium. Evidence does suggest that dexmedetomidine may allow for avoidance of deep sedation and use of benzodiazepines, factors both observed to increase the risk for developing delirium. Our assessment of currently published literature highlights the need for ongoing research to better delineate the role of dexmedetomidine for delirium prevention

    Combined Use of High-Sensitive Cardiac Troponin, Copeptin, and the Modified HEART Score for Rapid Evaluation of Chest Pain Patients.

    Get PDF
    Clinical short-term risk stratification is a recommended approach in patients with chest pain and possible acute myocardial infarction (AMI) to further improve high safety of biomarker-based rule-out algorithms. The study aim was to assess clinical performance of baseline concentrations of high-sensitivity cardiac troponin T (hs-TnT) and copeptin and the modified HEART score (mHS) in early presenters to the emergency department with chest pain. This cohort study included patients with chest pain with onset maximum of 6 h before admission and no persistent ST-segment elevation on electrocardiogram. hs-TnT, copeptin, and the mHS were assessed from admission data. The diagnostic and prognostic value for three baseline rule-out algorithms: (1) single hs-TnT < 14 ng/l, (2) hs-TnT < 14 ng/l/mHS ≤ 3, and (3) hs-TnT < 14 ng/l/mHS ≤ 3/copeptin < 17.4 pmol/l, was assessed with sensitivity and negative predictive value. Primary diagnostic endpoint was the diagnosis of AMI. Prognostic endpoint was death and/or AMI within 30 days. Among 154 enrolled patients, 44 (29%) were classified as low-risk according to the mHS; AMI was diagnosed in 105 patients (68%). For ruling out AMI, the highest sensitivity and NPV from all studied algorithms were observed for hs-TnT/mHS/copeptin (100%, 95% CI 96.6-100, and 100%, 95% CI 75.3-100). At 30 days, the highest event-free survival was achieved in patients stratified with hs-TnT/mHS/copeptin algorithm (100%) with 100% (95% CI 75.3-100) NPV and 100% (95% CI 96.6-100) sensitivity. The combination of baseline hs-TnT, copeptin, and the mHS has an excellent sensitivity and NPV for short-term risk stratification. Such approach might improve the triage system in emergency departments and be a bridge for inclusion to serial blood sampling algorithms

    Predicting Major Adverse Events in Patients With Acute Myocardial Infarction

    Get PDF
    Early and accurate detection of short-term major adverse cardiac events (MACE) in patients with suspected acute myocardial infarction (AMI) is an unmet clinical need.; The goal of this study was to test the hypothesis that adding clinical judgment and electrocardiogram findings to the European Society of Cardiology (ESC) high-sensitivity cardiac troponin (hs-cTn) measurement at presentation and after 1 h (ESC hs-cTn 0/1 h algorithm) would further improve its performance to predict MACE.; Patients presenting to an emergency department with suspected AMI were enrolled in a prospective, multicenter diagnostic study. The primary endpoint was MACE, including all-cause death, cardiac arrest, AMI, cardiogenic shock, sustained ventricular arrhythmia, and high-grade atrioventricular block within 30 days including index events. The secondary endpoint was MACE + unstable angina (UA) receiving early (≤24 h) revascularization.; Among 3,123 patients, the ESC hs-cTnT 0/1 h algorithm triaged significantly more patients toward rule-out compared with the extended algorithm (60%; 95% CI: 59% to 62% vs. 45%; 95% CI: 43% to 46%; p < 0.001), while maintaining similar 30-day MACE rates (0.6%; 95% CI: 0.3% to 1.1% vs. 0.4%; 95% CI: 0.1% to 0.9%; p = 0.429), resulting in a similar negative predictive value (99.4%; 95% CI: 98.9% to 99.6% vs. 99.6%; 95% CI: 99.2% to 99.8%; p = 0.097). The ESC hs-cTnT 0/1 h algorithm ruled-in fewer patients (16%; 95% CI: 14.9% to 17.5% vs. 26%; 95% CI: 24.2% to 27.2%; p < 0.001) compared with the extended algorithm, albeit with a higher positive predictive value (76.6%; 95% CI: 72.8% to 80.1% vs. 59%; 95% CI: 55.5% to 62.3%; p < 0.001). For 30-day MACE + UA, the ESC hs-cTnT 0/1 h algorithm had a higher positive predictive value for rule-in, whereas the extended algorithm had a higher negative predictive value for the rule-out. Similar findings emerged when using hs-cTnI.; The ESC hs-cTn 0/1 h algorithm better balanced efficacy and safety in the prediction of MACE, whereas the extended algorithm is the preferred option for the rule-out of 30-day MACE + UA. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587)

    Thermal Evolution of the Proton Irradiated Structure in Tungsten–5 wt% Tantalum

    Get PDF
    We have monitored the thermal evolution of the proton irradiated structure of W–5 wt% Ta alloy by in-situ annealing in a transmission electron microscope at fusion reactor temperatures of 500–1300 °C. The interstitial-type a/2 dislocation loops emit self-interstitial atoms and glide to the free sample surface during the early stages of annealing. The resultant vacancy excess in the matrix originates vacancy-type a/2 dislocation loops that grow by loop and vacancy absorption in the temperature range of 600–900 °C. Voids form at 1000 °C, by either vacancy absorption or loop collapse, and grow progressively up to 1300 °C. Tantalum delays void formation by a vacancy-solute trapping mechanism

    Circadian rhythm of cardiac troponin I and its clinical impact on the diagnostic accuracy for acute myocardial infarction

    Get PDF
    High-sensitivity cardiac troponin T (hs-cTnT) blood concentrations were shown to exhibit a diurnal rhythm, characterized by gradually decreasing concentrations throughout daytime, rising concentrations during nighttime and peak concentrations in the morning. We aimed to investigate whether this also applies to (h)s-cTnI assays and whether it would affect diagnostic accuracy for acute myocardial infarction (AMI).; Blood concentrations of cTnI were measured at presentation and after 1 h using four different cTnI assays: three commonly used sensitive (s-cTnI Architect, Ultra and Accu) and one experimental high-sensitivity assay (hs-cTnI Accu) in a prospective multicenter diagnostic study of patients presenting to the emergency department with suspected AMI. These concentrations and their diagnostic accuracy for AMI (quantified by the area under the curve (AUC)) were compared between morning (11 p.m. to 2 p.m.) and evening (2 p.m. to 11 p.m.) presenters.; Among 2601 patients, AMI was the final diagnosis in 17.6% of patients. Concentrations of (h)s-cTnI as measured using all four assays were comparable in patients presenting in the morning versus patients presenting in the evening. Diagnostic accuracy for AMI of all four (h)s-cTnI assays were high and comparable between patients presenting in the morning versus presenting in the evening (AUC at presentation: 0.90 vs 0.93 for s-cTnI Architect; 0.91 vs 0.94 for s-cTnI Ultra; 0.89 vs 0.94 for s-cTnI Accu; 0.91 vs 0.94 for hs-cTnI Accu).; Cardiac TnI does not seem to express a diurnal rhythm. Diagnostic accuracy for AMI is very high and does not differ with time of presentation.; NCT00470587, http://clinicaltrials.gov/show/NCT00470587

    Ultrafine grained plates of Al-Mg-Si alloy obtained by Incremental Equal Channel Angular Pressing : microstructure and mechanical properties

    Get PDF
    In this study, an Al-Mg-Si alloy was processed using via Incremental Equal Channel Angular Pressing (I-ECAP) in order to obtain homogenous, ultrafine grained plates with low anisotropy of the mechanical properties. This was the first attempt to process an Al-Mg-Si alloy using this technique. Samples in the form of 3 mm-thick square plates were subjected to I-ECAP with the 90˚ rotation around the axis normal to the surface of the plate between passes. Samples were investigated first in their initial state, then after a single pass of I-ECAP and finally after four such passes. Analyses of the microstructure and mechanical properties demonstrated that the I-ECAP method can be successfully applied in Al-Mg-Si alloys. The average grain size decreased from 15 - 19 µm in the initial state to below 1 µm after four I-ECAP passes. The fraction of high angle grain boundaries in the sample subjected to four I-ECAP passes lay within 53-57 % depending on the examined plane. The mechanism of grain refinement in Al-Mg-Si alloy was found to be distinctly different from that in pure aluminium with the grain rotation being more prominent than the grain subdivision, which was attributed to lower stacking fault energy and the reduced mobility of dislocations in the alloy. The ultimate tensile strength increased more than twice, whereas the yield strength - more than threefold. Additionally, the plates processed by I-ECAP exhibited low anisotropy of mechanical properties (in plane and across the thickness) in comparison to other SPD processing methods, which makes them attractive for further processing and applications
    corecore