21 research outputs found

    Design and assembly of a catalyst bed gas generator for the catalytic decomposition of high concentration hydrogen peroxide propellants and the catalytic combustion of hydrocarbon/air mixtures

    Get PDF
    A method for designing and assembling a high performance catalyst bed gas generator for use in decomposing propellants, particularly hydrogen peroxide propellants, for use in target, space, and on-orbit propulsion systems and low-emission terrestrial power and gas generation. The gas generator utilizes a sectioned catalyst bed system, and incorporates a robust, high temperature mixed metal oxide catalyst. The gas generator requires no special preheat apparatus or special sequencing to meet start-up requirements, enabling a fast overall response time. The high performance catalyst bed gas generator system has consistently demonstrated high decomposition efficiency, extremely low decomposition roughness, and long operating life on multiple test articles

    High-temperature catalyst for catalytic combustion and decomposition

    Get PDF
    A robust, high temperature mixed metal oxide catalyst for propellant composition, including high concentration hydrogen peroxide, and catalytic combustion, including methane air mixtures. The uses include target, space, and on-orbit propulsion systems and low-emission terrestrial power and gas generation. The catalyst system requires no special preheat apparatus or special sequencing to meet start-up requirements, enabling a fast overall response time. Start-up transients of less than 1 second have been demonstrated with catalyst bed and propellant temperatures as low as 50 degrees Fahrenheit. The catalyst system has consistently demonstrated high decomposition effeciency, extremely low decomposition roughness, and long operating life on multiple test particles

    Application of a mixed metal oxide catalyst to a metallic substrate

    Get PDF
    A method for applying a mixed metal oxide catalyst to a metallic substrate for the creation of a robust, high temperature catalyst system for use in decomposing propellants, particularly hydrogen peroxide propellants, for use in propulsion systems. The method begins by forming a prepared substrate material consisting of a metallic inner substrate and a bound layer of a noble metal intermediate. Alternatively, a bound ceramic coating, or frit, may be introduced between the metallic inner substrate and noble metal intermediate when the metallic substrate is oxidation resistant. A high-activity catalyst slurry is applied to the surface of the prepared substrate and dried to remove the organic solvent. The catalyst layer is then heat treated to bind the catalyst layer to the surface. The bound catalyst layer is then activated using an activation treatment and calcinations to form the high-activity catalyst system

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Microbial Dynamics Associated with Decomposing \u3ci\u3eTypha angustifolia\u3c/i\u3e Litter in two Contrasting Lake Erie Coastal Wetlands

    No full text
    We compared the decomposition of sediment-associated litter of Typha angustifolia in 2 Lake Erie coastal wetlands, examining the effects of sedimentation on microbial biomass, production and litter decay dynamics. Experimental manipulations of sediment had no statistically significant effect (p \u3e 0.05) on microbial biomass or metabolism. However, unforeseen differences between wetland sites (i.e. permanently inundated vs. exposed) had a major influence on microbial colonization and growth, litter mass loss, and nutrient dynamics. Litter-associated bacterial biomass and production were greater at the inundated site vs. the exposed wetland site (e.g. 487 vs. 158 µg C g–1 detrital C after 146 d, respectively). In contrast, fungal biomass and production were greater at the exposed site (e.g. 125 vs. 56 mg C g–1 detrital C after 146 d, respectively). Microbial degradative enzymes involved in the acquisition of phosphorus, nitrogen and carbon followed similar patterns as observed for fungal biomass and production, with higher activities associated with decaying litter at the exposed site. Microbial respiration rates were initially similar at both sites, but increased at the inundated site towards the end of the study period. Despite greater litter-associated microbial biomass, production and enzyme activities at the exposed wetland site, rates of litter mass loss were similar, suggesting that the greater metabolic potential of microbiota at the exposed site may have been offset by environmental conditions (e.g. fluctuations in water availability). Although mass loss rates were similar, significant differences in nutrient dynamics were observed, with higher N and P associated with higher litter-associated microbial biomass. These results illustrate how microbial decay dynamics can potentially interact with environmental variables (e.g. water availability) to modulate the carbon and nutrient dynamics of a litter resource that dominates many wetlands

    Immunocompromised patients with acute respiratory distress syndrome: Secondary analysis of the LUNG SAFE database

    Get PDF
    Background: The aim of this study was to describe data on epidemiology, ventilatory management, and outcome of acute respiratory distress syndrome (ARDS) in immunocompromised patients. Methods: We performed a post hoc analysis on the cohort of immunocompromised patients enrolled in the Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE) study. The LUNG SAFE study was an international, prospective study including hypoxemic patients in 459 ICUs from 50 countries across 5 continents. Results: Of 2813 patients with ARDS, 584 (20.8%) were immunocompromised, 38.9% of whom had an unspecified cause. Pneumonia, nonpulmonary sepsis, and noncardiogenic shock were their most common risk factors for ARDS. Hospital mortality was higher in immunocompromised than in immunocompetent patients (52.4% vs 36.2%; p &lt; 0.0001), despite similar severity of ARDS. Decisions regarding limiting life-sustaining measures were significantly more frequent in immunocompromised patients (27.1% vs 18.6%; p &lt; 0.0001). Use of noninvasive ventilation (NIV) as first-line treatment was higher in immunocompromised patients (20.9% vs 15.9%; p = 0.0048), and immunodeficiency remained independently associated with the use of NIV after adjustment for confounders. Forty-eight percent of the patients treated with NIV were intubated, and their mortality was not different from that of the patients invasively ventilated ab initio. Conclusions: Immunosuppression is frequent in patients with ARDS, and infections are the main risk factors for ARDS in these immunocompromised patients. Their management differs from that of immunocompetent patients, particularly the greater use of NIV as first-line ventilation strategy. Compared with immunocompetent subjects, they have higher mortality regardless of ARDS severity as well as a higher frequency of limitation of life-sustaining measures. Nonetheless, nearly half of these patients survive to hospital discharge. Trial registration: ClinicalTrials.gov, NCT02010073. Registered on 12 December 2013

    Validation and utility of ARDS subphenotypes identified by machine-learning models using clinical data: an observational, multicohort, retrospective analysis

    No full text
    International audienceTwo acute respiratory distress syndrome (ARDS) subphenotypes (hyperinflammatory and hypoinflammatory) with distinct clinical and biological features and differential treatment responses have been identified using latent class analysis (LCA) in seven individual cohorts. To facilitate bedside identification of subphenotypes, clinical classifier models using readily available clinical variables have been described in four randomised controlled trials. We aimed to assess the performance of these models in observational cohorts of ARDS. Methods: In this observational, multicohort, retrospective study, we validated two machine-learning clinical classifier models for assigning ARDS subphenotypes in two observational cohorts of patients with ARDS: Early Assessment of Renal and Lung Injury (EARLI; n=335) and Validating Acute Lung Injury Markers for Diagnosis (VALID; n=452), with LCA-derived subphenotypes as the gold standard. The primary model comprised only vital signs and laboratory variables, and the secondary model comprised all predictors in the primary model, with the addition of ventilatory variables and demographics. Model performance was assessed by calculating the area under the receiver operating characteristic curve (AUC) and calibration plots, and assigning subphenotypes using a probability cutoff value of 0·5 to determine sensitivity, specificity, and accuracy of the assignments. We also assessed the performance of the primary model in EARLI using data automatically extracted from an electronic health record (EHR; EHR-derived EARLI cohort). In Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE; n=2813), a multinational, observational ARDS cohort, we applied a custom classifier model (with fewer variables than the primary model) to determine the prognostic value of the subphenotypes and tested their interaction with the positive end-expiratory pressure (PEEP) strategy, with 90-day mortality as the dependent variable. Findings: The primary clinical classifier model had an area under receiver operating characteristic curve (AUC) of 0·92 (95% CI 0·90–0·95) in EARLI and 0·88 (0·84–0·91) in VALID. Performance of the primary model was similar when using exclusively EHR-derived predictors compared with manually curated predictors (AUC=0·88 [95% CI 0·81–0·94] vs 0·92 [0·88–0·97]). In LUNG SAFE, 90-day mortality was higher in patients assigned the hyperinflammatory subphenotype than in those with the hypoinflammatory phenotype (414 [57%] of 725 vs 694 [33%] of 2088; p<0·0001). There was a significant treatment interaction with PEEP strategy and ARDS subphenotype (p=0·041), with lower 90-day mortality in the high PEEP group of patients with the hyperinflammatory subphenotype (hyperinflammatory subphenotype: 169 [54%] of 313 patients in the high PEEP group vs 127 [62%] of 205 patients in the low PEEP group; hypoinflammatory subphenotype: 231 [34%] of 675 patients in the high PEEP group vs 233 [32%] of 734 patients in the low PEEP group). Interpretation: Classifier models using clinical variables alone can accurately assign ARDS subphenotypes in observational cohorts. Application of these models can provide valuable prognostic information and could inform management strategies for personalised treatment, including application of PEEP, once prospectively validated. Funding: US National Institutes of Health and European Society of Intensive Care Medicine

    Outcome of acute hypoxaemic respiratory failure: insights from the LUNG SAFE Study

    No full text
    Background: Current incidence and outcome of patients with acute hypoxaemic respiratory failure requiring mechanical ventilation in the intensive care unit (ICU) are unknown, especially for patients not meeting criteria for acute respiratory distress syndrome (ARDS). Methods: An international, multicentre, prospective cohort study of patients presenting with hypoxaemia early in the course of mechanical ventilation, conducted during four consecutive weeks in the winter of 2014 in 459 ICUs from 50 countries (LUNG SAFE). Patients were enrolled with arterial oxygen tension/inspiratory oxygen fraction ratio ≤300 mmHg, new pulmonary infiltrates and need for mechanical ventilation with a positive end-expiratory pressure of ≥5 cmH2O. ICU prevalence, causes of hypoxaemia, hospital survival and factors associated with hospital mortality were measured. Patients with unilateral versus bilateral opacities were compared. Findings: 12 906 critically ill patients received mechanical ventilation and 34.9% with hypoxaemia and new infiltrates were enrolled, separated into ARDS (69.0%), unilateral infiltrate (22.7%) and congestive heart failure (CHF; 8.2%). The global hospital mortality was 38.6%. CHF patients had a mortality comparable to ARDS (44.1% versus 40.4%). Patients with unilateral-infiltrate had lower unadjusted mortality, but similar adjusted mortality compared to those with ARDS. The number of quadrants on chest imaging was associated with an increased risk of death. There was no difference in mortality comparing patients with unilateral-infiltrate and ARDS with only two quadrants involved. Interpretation: More than one-third of patients receiving mechanical ventilation have hypoxaemia and new infiltrates with a hospital mortality of 38.6%. Survival is dependent on the degree of pulmonary involvement whether or not ARDS criteria are reached

    Outcomes of Patients Presenting with Mild Acute Respiratory Distress Syndrome Insights from the LUNG SAFE Study

    No full text
    BACKGROUND: Patients with initial mild acute respiratory distress syndrome are often underrecognized and mistakenly considered to have low disease severity and favorable outcomes. They represent a relatively poorly characterized population that was only classified as having acute respiratory distress syndrome in the most recent definition. Our primary objective was to describe the natural course and the factors associated with worsening and mortality in this population. METHODS: This study analyzed patients from the international prospective Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE) who had initial mild acute respiratory distress syndrome in the first day of inclusion. This study defined three groups based on the evolution of severity in the first week: "worsening" if moderate or severe acute respiratory distress syndrome criteria were met, "persisting" if mild acute respiratory distress syndrome criteria were the most severe category, and "improving" if patients did not fulfill acute respiratory distress syndrome criteria any more from day 2. RESULTS: Among 580 patients with initial mild acute respiratory distress syndrome, 18% (103 of 580) continuously improved, 36% (210 of 580) had persisting mild acute respiratory distress syndrome, and 46% (267 of 580) worsened in the first week after acute respiratory distress syndrome onset. Global in-hospital mortality was 30% (172 of 576; specifically 10% [10 of 101], 30% [63 of 210], and 37% [99 of 265] for patients with improving, persisting, and worsening acute respiratory distress syndrome, respectively), and the median (interquartile range) duration of mechanical ventilation was 7 (4, 14) days (specifically 3 [2, 5], 7 [4, 14], and 11 [6, 18] days for patients with improving, persisting, and worsening acute respiratory distress syndrome, respectively). Admissions for trauma or pneumonia, higher nonpulmonary sequential organ failure assessment score, lower partial pressure of alveolar oxygen/fraction of inspired oxygen, and higher peak inspiratory pressure were independently associated with worsening. CONCLUSIONS: Most patients with initial mild acute respiratory distress syndrome continue to fulfill acute respiratory distress syndrome criteria in the first week, and nearly half worsen in severity. Their mortality is high, particularly in patients with worsening acute respiratory distress syndrome, emphasizing the need for close attention to this patient population.status: publishe
    corecore