40 research outputs found

    Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Get PDF
    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios up to 100 ppbv. The CRM technique has hitherto mainly been used in low-NOx environments, i.e. environments with ambient NOx mixing ratios lower than a few ppbv, due to a measurement artifact generated by ambient NO inside the sampling reactor. However, this study shows that this technique can also be used under NOx-rich conditions if a NOx-dependent correction is carefully applied on the OH reactivity measurements. A full suite of 52 VOCs, NOx, and other inorganic species were monitored during this intercomparison. An investigation of the OH reactivity budget for this urban site suggests that this suite of trace gases can account for the measured total OH reactivity

    Comparison of OH reactivity measurements in the atmospheric simulation chamber SAPHIR

    Get PDF
    Hydroxyl (OH) radical reactivity (kOH) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum JĂŒlich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements (limit of detection  < 1 s−1 at a time resolution of 30 s to a few minutes) is higher for instruments directly detecting hydroxyl radicals, whereas the indirect comparative reactivity method (CRM) has a higher limit of detection of 2 s−1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapour or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds (mixing ratio of OH reactants were up to 10 ppbv). In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied to account for known effects of, for example, deviations from pseudo first-order conditions, nitrogen oxides or water vapour on the measurement. Methods used to derive these corrections vary among the different CRM instruments. Measurements taken with a flow-tube instrument combined with the direct detection of OH by chemical ionisation mass spectrometry (CIMS) show limitations in cases of high reactivity and high NO concentrations but were accurate for low reactivity (< 15 s−1) and low NO (< 5 ppbv) conditions

    ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO GAW and EMEP observation networks

    Get PDF
    The performance of 18 European institutions involved in long-term non-methane hydrocarbon (NMHC) measurements in ambient air within the framework of the Global Atmosphere Watch (GAW) and the European Monitoring and Evaluation Programme (EMEP) was assessed with respect to data quality objectives (DQOs) of ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) and GAW. Compared to previous intercomparison studies the DQOs define a novel approach to assess and ensure a high quality of the measurements. Having already been adopted by GAW, the ACTRIS DQOs are demanding with deviations to a reference value of less than 5% and a repeatability of better than 2% for NMHC mole fractions above 0.1 nmol mol(-1). The participants of the intercomparison analysed two dry gas mixtures in pressurised cylinders, a 30-component NMHC mixture in nitrogen (NMHC_N-2 /at approximately 1 nmol mol(-1) and a whole air sample (NMHC_air), following a standardised operation procedure including zero-and calibration gas measurements. Furthermore, participants had to report details on their instruments and assess their measurement uncertainties. The NMHCs were analysed either by gas chromatography-flame ionisation detection (GC-FID) or by gas chromatography-mass spectrometry (GC-MS). For the NMHC_N-2 measurements, 62% of the reported values were within the 5% deviation class corresponding to the ACTRIS DQOs. For NMHC_air, generally more frequent and larger deviations to the assigned values were observed, with 50% of the reported values within the 5% deviation class. Important contributors to the poorer performance in NMHC_air compared to NMHC_N-2 were a more complex matrix and a larger span of NMHC mole fractions (0.03-2.5 nmol mol(-1)). The performance of the participating laboratories were affected by the different measurement procedures such as the usage of a two-step vs. a one-step calibration, breakthroughs of C-2-C-3 hydrocarbons in the focussing trap, blank values in zero-gas measurements (especially for those systems using a Nafion (R) Dryer), adsorptive losses of aromatic compounds, and insufficient chromatographic separation.Peer reviewe

    Fast sorption measurements of volatile organic compounds on building materials: Part 1 – Methodology developed for field applications

    Get PDF
    A Proton Transfer Reaction-Mass Spectrometer (PTR-MS) has been coupled to the outlet of a Field and Laboratory Emission Cell (FLEC), to measure volatile organic compounds (VOC) concentration during a sorption experiments (Rizk et al., this issue) [1]. The limits of detection of the PTR-MS for three VOCs are presented for different time resolution (2, 10 and 20 s). The mass transfer coefficient was calculated in the FLEC cavity for the different flow rates. The concentration profile obtained from a sorption experiment performed on a gypsum board and a vinyl flooring are also presented in comparison with the profile obtained for a Pyrex glass used as a material that do not present any sorption behavior (no sink). Finally, the correlation between the concentration of VOCs adsorbed on the surface of the gypsum board at equilibrium (Cse) and the concentration of VOCs Ce measured in the gas phase at equilibrium is presented for benzene, C8 aromatics and toluene

    .

    No full text
    International audienc
    corecore