32 research outputs found

    Type 1 Diabetes Mellitus reversal via implantation of magnetically purified microencapsulated pseudoislets

    Get PDF
    [Abstract] Microencapsulation of pancreatic islets for the treatment of Type I Diabetes Mellitus (T1DM) generates a high quantity of empty microcapsules, resulting in high therapeutic graft volumes that can enhance the host’s immune response. We report a 3D printed microfluidic magnetic sorting device for microcapsules purification with the objective to reduce the number of empty microcapsules prior transplantation. In this study, INS1E pseudoislets were microencapsulated within alginate (A) and alginate-poly-L-lysine-alginate (APA) microcapsules and purified through the microfluidic device. APA microcapsules demonstrated higher mechanical integrity and stability than A microcapsules, showing better pseudoislets viability and biological function. Importantly, we obtained a reduction of the graft volume of 77.5% for A microcapsules and 78.6% for APA microcapsules. After subcutaneous implantation of induced diabetic Wistar rats with magnetically purified APA microencapsulated pseudoislets, blood glucose levels were restored into normoglycemia (<200 mg/dL) for almost 17 weeks. In conclusion, our described microfluidic magnetic sorting device represents a great alternative approach for the graft volume reduction of microencapsulated pseudoislets and its application in T1DM disease.Universidad del País Vasco; ESPPOC 16/65Universidad del País vasco; EHUa16/06Gobierno Vasco; IT907-16Gobierno Vasco; KK-2017/0000088Gobierno Vasco; 307616FKA4Ministerio de Economía y Competitividad; RYC-2012-1079

    Compromiso por la calidad de las sociedades científicas en España

    Get PDF
    En este artículo se resumen los objetivos, la metodología y las primeras conclusiones del proyecto «Compromiso por la calidad de las sociedades científicas en España», coordinado por el Ministerio de Sanidad, Servicios Sociales e Igualdad, la Sociedad Española de Medicina Interna y el Instituto Aragonés de Ciencias de la Salud, en el que participan 48 sociedades científicas. Los objetivos de este proyecto son: disminuir la utilización de intervenciones médicas innecesarias, que son las que no han demostrado eficacia, tienen escasa o dudosa efectividad, o no son coste-efectivas; disminuir la variabilidad en la práctica clínica; difundir entre médicos y pacientes el compromiso con el uso adecuado de recursos sanitarios y, por último, promover la seguridad clínica. En el documento se incluyen 135 recomendaciones finales de «no hacer» elaboradas por 30 sociedades científicas españolas. This article summarises the objectives, methodology and initial conclusions of the project “Commitment to Quality of the Spanish Scientific Societies”, coordinated by the Ministry of Health, Social Services and Equality, the Spanish Society of Internal Medicine and the Aragon Institute of Health Sciences, in which 48 scientific societies participate. This project's objectives are to decrease the use of unnecessary medical interventions, which are those that have shown no efficacy, have little or questionable effectiveness or are not cost-effective; decrease variability in clinical practice; promote the commitment among physicians and patients to properly use healthcare resources; and to promote clinical safety. The document includes 135 final recommendations for what not to do, prepared by 30 Spanish scientific societies

    A new view of electrochemistry at highly oriented pyrolytic graphite

    Get PDF
    Major new insights on electrochemical processes at graphite electrodes are reported, following extensive investigations of two of the most studied redox couples, Fe(CN)64–/3– and Ru(NH3)63+/2+. Experiments have been carried out on five different grades of highly oriented pyrolytic graphite (HOPG) that vary in step-edge height and surface coverage. Significantly, the same electrochemical characteristic is observed on all surfaces, independent of surface quality: initial cyclic voltammetry (CV) is close to reversible on freshly cleaved surfaces (>400 measurements for Fe(CN)64–/3– and >100 for Ru(NH3)63+/2+), in marked contrast to previous studies that have found very slow electron transfer (ET) kinetics, with an interpretation that ET only occurs at step edges. Significantly, high spatial resolution electrochemical imaging with scanning electrochemical cell microscopy, on the highest quality mechanically cleaved HOPG, demonstrates definitively that the pristine basal surface supports fast ET, and that ET is not confined to step edges. However, the history of the HOPG surface strongly influences the electrochemical behavior. Thus, Fe(CN)64–/3– shows markedly diminished ET kinetics with either extended exposure of the HOPG surface to the ambient environment or repeated CV measurements. In situ atomic force microscopy (AFM) reveals that the deterioration in apparent ET kinetics is coupled with the deposition of material on the HOPG electrode, while conducting-AFM highlights that, after cleaving, the local surface conductivity of HOPG deteriorates significantly with time. These observations and new insights are not only important for graphite, but have significant implications for electrochemistry at related carbon materials such as graphene and carbon nanotubes

    Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country

    Get PDF
    BACKGROUND: Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. OBJECTIVE: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. MATERIAL AND METHODS: We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). RESULTS: Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). CONCLUSION: despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results

    Occurrence and ecological risk assessment of organic UV filters in coastal waters of the Iberian Peninsula

    Get PDF
    This study aimed to assess the presence of 21 UVFs and metabolites in coastal regions of the Iberian Peninsula, to evaluate their environmental risk, and identify possible influential factors affecting their measured concentrations. Sampling was carried out in spring and summer to assess possible seasonal variations. UVFs were detected in 43 of the 46 sampling sites. Only 5 were found above LOD: BP4, OC, BP3 and metabolites BP1 and BP8. Samples collected in Mar Menor had the greatest variety of compounds per sample and the highest cumulative concentrations. The risk was characterized using Risk Quotients (RQ). BP1 showed a Low environmental Risk in 2 sites while for OC the RQ indicated a Moderate Risk in 22 points. The variables that contribute most to the variation are population density, sampling season, whether it was an open bay or not, and level of urbanization. The presence of WWTPs had a lower influence.We thank the Rey Juan Carlos University Internal Program for the Promotion and Development of Research and Innovation – Bridge Grants 2020; the Spanish Ministry of Education and Professional Development, and the “Salvador Madariaga” Program in Support of Research Stays for Professor and Senior Researchers in Foreign Research Centres. A. Rico acknowledges the funding provided by the Talented Researcher Support Programme – PlanGenT(CIDEGENT/2020/043) of the Generalitat Valenciana. G. Quintana acknowledges the Spanish Ministry of Science and Innovation (Project CEX2018-000794-S) for his fellowship.Peer reviewe

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362
    corecore