64 research outputs found

    Carotid intima-media thickness and coronary atherosclerosis : weak or strong relations?

    Get PDF
    Aims Measurement of change in carotid intima-media thickness (CIMT) has been proposed as an alternative for the occurrence of cardiovascular (CV) events in the assessment of therapeutic interventions. Nevertheless, criticism has been voiced based on observations indicating a weak relation between CIMT and coronary atherosclerosis as well as on the virtual absence of data showing that progression of CIMT indeed predicts coronary artery disease (CAD) and stroke. Methods and results We set out to review the evidence on these issues by performing a literature search on these topics. Of the 34 studies on the relation of CIMT with coronary atherosclerosis, as assessed by angiography (n \ubc 33) or intravascular ultrasound (n \ubc 1), 30 showed a modest positive relationship; the magnitude of which was similar to that found in autopsy studies. Of all studies on CIMT and future CV events (n \ubc 18), 17 showed graded positive relationships. At present, only one study has provided evidence on the relation of change in CIMT and future CV events, showing an increased risk with CIMT progression. The paucity of data on progression and future CV risk is partly attributable to time windows required to complete these studies. Conclusion The modest relation between CIMT and coronary atherosclerosis most likely reflects variability in atherosclerosis development between the vascular beds rather than limitations of CIMT measurements. Additional data on the relation between change in CIMT and future CV events is required and currently is in progres

    Novel Loci for Adiponectin Levels and Their Influence on Type 2 Diabetes and Metabolic Traits : A Multi-Ethnic Meta-Analysis of 45,891 Individuals

    Get PDF
    J. Kaprio, S. Ripatti ja M.-L. Lokki työryhmien jäseniä.Peer reviewe

    Patients with premature coronary artery disease who carry the ABCC6 R1141X mutation have no Pseudoxanthoma Elasticum phenotype

    No full text
    Background: Pseudoxanthoma elasticurn (PXE) is an inherited disorder of elastic tissue. We recently found that heterozygosity for the frequent (0.8% prevalence in Dutch population) R 1141 X mutation in the PXE gene coding for the ABCC6 transporter, is associated with a fourfold risk of premature coronary artery disease. Yet, it is not clear whether or not heterozygosity for this mutation results in a mild PXE phenotype. The objective of our study was to determine if skin and/or eye abnormalities related to a PXE phenotype could be found in patients with premature coronary artery disease, with and without the R 1141 X mutation. Methods: R1141X mutation carriers with premature coronary artery disease (cases) and patients with premature coronary artery disease with no-or not known-mutation (controls) were studied. Cases and controls were examined for PXE-like skin changes and retinal angioid streaks, peau d'orange or pigment epithelium changes. Results: 7 cases and 31 controls were analysed. In both the mutation-positive and the control group, skin inspection and eye fundus examination did not reveal any dermatological or ocular signs of PXE. Conclusions: Carriers for the ABCC6 R 114 1 X mutation, which is frequent and confers a high risk of premature coronary artery disease, do not commonly have skin or eye abnormalities consistent with a mild PXE phenotype. (c) 2004 Elsevier Ireland Ltd. All rights reserve

    Clinical Trials Report

    No full text

    Completeness of carotid intima media thickness measurements depends on body composition: the RADIANCE 1 and 2 trials.

    Get PDF
    Contains fulltext : 89728.pdf (publisher's version ) (Open Access)AIM: Ultrasound protocols to measure carotid intima media thickness (CIMT) differ considerably with regard to the inclusion of the number of carotid segments and angles used. Detailed information on the completeness of CIMT information is often lacking in published reports, and at most, overall percentages are presented. We therefore decided to study the completeness of CIMT measurements and its relation with vascular risk factors using data from two CIMT intervention studies: one among familial hypercholesterolemia (FH) patients, the Rating Atherosclerotic Disease change by Imaging With A New CETP Inhibitor (RADIANCE 1), and one among mixed dyslipidemia (MD) patients, the Rating Atherosclerotic Disease change by Imaging With A New CETP Inhibitor (RADIANCE 2). METHODS: We used baseline ultrasound scans from the RADIANCE 1 (n=872) and RADIANCE 2 (n=752) studies. CIMT images were recorded for 12 artery-wall combinations (near and far walls of the left and right common carotid artery (CCA), bifurcation (BIF) and internal carotid artery (ICA) segments) at 4 set angles, resulting in 48 possible measurements per patient. The presence or absence of CIMT measurements was assessed per artery-wall combination and per angle. The relation between completeness and patient characteristics was evaluated with logistic regression analysis. RESULTS: In 89% of the FH patients, information on CIMT could be obtained on all twelve carotid segments, and in 7.6%, eleven segments had CIMT information (nearly complete 96.6%). For MD patients this was 74.6% and 17.9%, respectively (nearly complete: 92.5%). Increased body mass index and increased waist circumference were significantly (p=0.01) related to less complete data in FH patients. For MD patients, relations were seen with increased waist circumference (p98%). In MD patients, completeness was lower for the near wall of both the right and left carotid arteries: 86.0% and 90.8%, respectively, as compared to other segments (all >97%). CONCLUSIONS: With the current ultrasound protocols it is possible to obtain a very high level of completeness. Apart from the population studied, body mass index and waist circumference are important in achieving complete CIMT measurements

    ENHANCE and ACCORD: Controversy over surrogate end points

    No full text

    Pregnancy in women suffering from familial hypercholesterolemia: a harmful period for both mother and newborn?

    No full text
    Contains fulltext : 81899.pdf (publisher's version ) (Closed access)PURPOSE OF REVIEW: The present review aims to highlight the consequences for mother and child of profound hypercholesterolemia during pregnancy of women with familial hypercholesterolemia. RECENT FINDINGS: Familial hypercholesterolemia is increasingly diagnosed in younger patients due to the existence of screening programs and more widespread cholesterol testing. Increasing numbers of young female patients with familial hypercholesterolemia raise the issue of pregnancy and its consequences for the familial hypercholesterolemia patient herself but also for her offspring. When pregnancy is considered, lipid-lowering drugs are often discontinued because of the fear for teratogenic effects. The evidence for teratogenesis associated with statin use is scant and conflicting. On the other hand, several studies do suggest that pronounced hypercholesterolemia during pregnancy has adverse effects on both fetus and mother. In fact, human and animal studies reveal an enhanced tendency toward atherosclerosis in the offspring of women who suffer from hypercholesterolemia during pregnancy. In animal studies, some evidence exists that this can be reversed by treatment with lipid-lowering and antioxidative agents. Until today, however, no human studies exist that have evaluated efficacy or safety of lipid-lowering interventions in pregnant women with familial hypercholesterolemia. SUMMARY: Altogether, the suggested relationship between severe hypercholesterolemia and enhanced atherosclerosis in offspring and possibly the mother warrants further confirmation and, consequently, studies that focus on therapeutic strategies that can safely lower cholesterol levels during pregnancy in these women

    Ultrasound protocols to measure carotid intima-media thickness in trials; comparison of reproducibility, rate of progression, and effect of intervention in subjects with familial hypercholesterolemia and subjects with mixed dyslipidemia.

    No full text
    Item does not contain fulltextBACKGROUND: Current ultrasound protocols to measure carotid intima-media thickness (CIMT) in trials rather differ. The ideal protocol combines high reproducibility with a high precision in the measurement of the rate of change in CIMT over time and with a precise estimate of a treatment effect. To study these aspects, a post-hoc analysis was performed using data from two randomized double-blind, placebo-controlled trials: one among 872 subjects with familial hypercholesterolemia (FH) and the other among 752 subjects with mixed dyslipidemia (MD), respectively. Participants were randomized to torcetrapib or placebo on top of optimal atorvastatin therapy. METHODS: CIMT information was collected from the left and right carotid artery from two walls (the near and far wall) of three segments (common carotid, bifurcation, and internal carotid artery) at four different angles (right: 90, 120, 150, and 180 degrees on Meijer's carotid arc; left: 270, 240, 210, and 180 degrees, respectively). Based on combinations of these measurements, 60 different protocols were constructed to estimate a CIMT measure per participant (20 protocols for mean common CIMT, 40 protocols for mean maximum CIMT). For each protocol we assessed reproducibility (intra-class correlation coefficient (ICC), mean difference of duplicate base-line scans); 2-year progression rate in the atorvastatin group with its standard error (SE); and treatment effect (difference in rate of change in CIMT between torcetrapib and placebo) with its SE. RESULTS: Reproducibility: ICC ranged from 0.77 to 0.91 among FH patients and from 0.68 to 0.86 among MD patients. CIMT progression rates ranged from -0.0030 to 0.0020 mm/year in the FH trial and from 0.00084 to 0.01057 mm/year in the MD trial, with SE ranging from 0.00054 to 0.00162 and from 0.00083 to 0.00229, respectively. The difference in CIMT progression rate between treatment arms ranged from -0.00133 to 0.00400 mm/year in the FH trial and from -0.00231 to 0.00486 mm/year in the MD trial. The protocol with the highest reproducibility, highest CIMT progression/precision ratio, and the highest treatment effect/precision ratio were those measuring mean common CIMT with measurements of the near and far wall at multiple angles. When the interest is in the mean maximum CIMT, protocols using multiple segments and angles performed the best. CONCLUSION: Our findings support the position that the number and specific combination of segments, angles, and walls interrogated are associated with differences in reproducibility, magnitude, and precision of progression of CIMT over time, and treatment effect. The best protocols were mean common CIMT protocols in which both the near and far walls are measured at multiple angles.1 september 201

    Evaluation of cholesterol lowering treatment of patients with familial hypercholesterolemia: a large cross-sectional study in The Netherlands.

    No full text
    Contains fulltext : 88642.pdf (publisher's version ) (Closed access)BACKGROUND: Heterozygous familial hypercholesterolemia (heFH) is a common autosomal dominant hereditary disorder caused by mutations in the LDL-receptor gene that lead to elevated plasma levels of low-density lipoprotein-cholesterol (LDL-c). Robust lowering of LDL-c levels is essential for risk reduction of premature cardiovascular diseases and early death. European and Dutch guidelines recommend to treat LDL-c to plasma levels or=2.5mmol/l, was acceptance of a higher target LDL-c level by the treating physician. An alternative treatment goal of >50% LDL-c reduction, as recommended in the NICE guidelines, was achieved in 47% of patients with an LDL-c >or=2.5mmol/l and not using maximum therapy. CONCLUSION: Only a small proportion of patients with heFH reaches the LDL-c treatment target of <2.5mmol/l. These results emphasize the need for better monitoring, better utilization of available medication and for new treatment options in heFH to further decrease LDL-c levels.1 maart 201
    corecore