150 research outputs found
The HADES RV Programme with HARPS-N@TNG IV. Time resolved analysis of the Ca ii H&K and H{\alpha} chromospheric emission of low-activity early-type M dwarfs
M dwarfs are prime targets for planet search programs, particularly of those
focused on the detection and characterization of rocky planets in the habitable
zone. Understanding their magnetic activity is important because it affects our
ability to detect small planets, and it plays a key role in the
characterization of the stellar environment. We analyze observations of the Ca
II H&K and H{\alpha} lines as diagnostics of chromospheric activity for
low-activity early-type M dwarfs. We analyze the time series of spectra of 71
early-type M dwarfs collected for the HADES project for planet search purposes.
The HARPS-N spectra provide simultaneously the H&K doublet and the H{\alpha}
line. We develop a reduction scheme able to correct the HARPS-N spectra for
instrumental and atmospheric effects, and to provide flux-calibrated spectra in
units of flux at the stellar surface. The H&K and H{\alpha} fluxes are compared
with each other, and their variability is analyzed. We find that the H and K
flux excesses are strongly correlated with each other, while the H{\alpha} flux
excess is generally less correlated with the H&K doublet. We also find that
H{\alpha} emission does not increase monotonically with the H&K line flux,
showing some absorption before being filled in by chromospheric emission when
H&K activity increases. Analyzing the time variability of the emission fluxes,
we derive a tentative estimate of the rotation period (of the order of a few
tens of days) for some of the program stars, and the typical lifetime of
chromospheric active regions (a few stellar rotations). Our results are in good
agreement with previous studies. In particular, we find evidence that the
chromospheres of early-type M dwarfs could be characterized by different
filaments coverage, affecting the formation mechanism of the H{\alpha} line. We
also show that chromospheric structure is likely related to spectral type
The Imaging Magnetograph eXperiment (IMaX) for the Sunrise balloon-borne solar observatory
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by
four institutions in Spain that flew on board the Sunrise balloon-borne
telesocope in June 2009 for almost six days over the Arctic Circle. As a
polarimeter IMaX uses fast polarization modulation (based on the use of two
liquid crystal retarders), real-time image accumulation, and dual beam
polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the
instrument uses a LiNbO3 etalon in double pass and a narrow band pre-filter to
achieve a spectral resolution of 85 mAA. IMaX uses the high Zeeman sensitive
line of Fe I at 5250.2 AA and observes all four Stokes parameters at various
points inside the spectral line. This allows vector magnetograms, Dopplergrams,
and intensity frames to be produced that, after reconstruction, reach spatial
resolutions in the 0.15-0.18 arcsec range over a 50x50 arcsec FOV. Time
cadences vary between ten and 33 seconds, although the shortest one only
includes longitudinal polarimetry. The spectral line is sampled in various ways
depending on the applied observing mode, from just two points inside the line
to 11 of them. All observing modes include one extra wavelength point in the
nearby continuum. Gauss equivalent sensitivities are four Gauss for
longitudinal fields and 80 Gauss for transverse fields per wavelength sample.
The LOS velocities are estimated with statistical errors of the order of 5-40
m/s. The design, calibration and integration phases of the instrument, together
with the implemented data reduction scheme are described in some detail.Comment: 17 figure
Advice on assistance and protection from the Scientific Advisory Board of the Organisation for the Prohibition of Chemical Weapons : Part 2. On preventing and treating health effects from acute, prolonged, and repeated nerve agent exposure, and the identification of medical countermeasures able to reduce or eliminate the longer term health effects of nerve agents
The Scientific Advisory Board (SAB) of the Organisation for the Prohibition of Chemical Weapons (OPCW) has provided advice in relation to the Chemical Weapons Convention on assistance and protection. We present the SAB’s response to a request from the OPCW Director-General in 2014 for information on the best practices for preventing and treating the health effects from acute, prolonged, and repeated organophosphorus nerve agent (NA) exposure. The report summarises pre- and post-exposure treatments, and developments in decontaminants and adsorbing materials, that at the time of the advice, were available for NAs. The updated information provided could assist medics and emergency responders unfamiliar with treatment and decontamination options related to exposure to NAs. The SAB recommended that developments in research on medical countermeasures and decontaminants for NAs should be monitored by the OPCW, and used in assistance and protection training courses and workshops organised through its capacity building programmes.Peer reviewe
Stereoscopic disambiguation of vector magnetograms: first applications to SO/PHI-HRT data
Spectropolarimetric reconstructions of the photospheric vector magnetic field
are intrinsically limited by the 180-ambiguity in the orientation of
the transverse component. So far, the removal of such an ambiguity has required
assumptions about the properties of the photospheric field, which makes
disambiguation methods model-dependent. The basic idea is that the unambiguous
line-of-sight component of the field measured from one vantage point will
generally have a non-zero projection on the ambiguous transverse component
measured by the second telescope, thereby determining the ``true'' orientation
of the transverse field. Such an idea was developed and implemented in the
Stereoscopic Disambiguation Method (SDM), which was recently tested using
numerical simulations. In this work we present a first application of the SDM
to data obtained by the High Resolution Telescope (HRT) onboard Solar Orbiter
during the March 2022 campaign, when the angle with Earth was 27 degrees. The
method is successfully applied to remove the ambiguity in the transverse
component of the vector magnetogram solely using observations (from HRT and
from the Helioseismic and Magnetic Imager), for the first time. The SDM is
proven to provide observation-only disambiguated vector magnetograms that are
spatially homogeneous and consistent. A discussion about the sources of error
that may limit the accuracy of the method, and of the strategies to remove them
in future applications, is also presented.Comment: 32 pages, 12 figures, accepted in A&A on 09/07/202
Magnetic fields inferred by Solar Orbiter: A comparison between SO/PHI-HRT and SDO/HMI
Context. The High Resolution Telescope (HRT) of the Polarimetric and Helioseismic Imager on board the Solar Orbiter spacecraft (SO/PHI) and the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) both infer the photospheric magnetic field from polarised light images. SO/PHI is the first magnetograph to move out of the Sun–Earth line and will provide unprecedented access to the Sun’s poles. This provides excellent opportunities for new research wherein the magnetic field maps from both instruments are used simultaneously.
Aims. We aim to compare the magnetic field maps from these two instruments and discuss any possible differences between them.
Methods. We used data from both instruments obtained during Solar Orbiter’s inferior conjunction on 7 March 2022. The HRT data were additionally treated for geometric distortion and degraded to the same resolution as HMI. The HMI data were re-projected to correct for the 3° separation between the two observatories.
Results. SO/PHI-HRT and HMI produce remarkably similar line-of-sight magnetograms, with a slope coefficient of 0.97, an offset below 1 G, and a Pearson correlation coefficient of 0.97. However, SO/PHI-HRT infers weaker line-of-sight fields for the strongest fields. As for the vector magnetic field, SO/PHI-HRT was compared to both the 720-second and 90-second HMI vector magnetic field: SO/PHI-HRT has a closer alignment with the 90-second HMI vector. In the weak signal regime (< 600 G), SO/PHI-HRT measures stronger and more horizontal fields than HMI, very likely due to the greater noise in the SO/PHI-HRT data. In the strong field regime (≳600 G), HRT infers lower field strengths but with similar inclinations (a slope of 0.92) and azimuths (a slope of 1.02). The slope values are from the comparison with the HMI 90-second vector. Possible reasons for the differences found between SO/PHI-HRT and HMI magnetic field parameters are discussed.Sección Deptal. de Óptica (Óptica)Fac. de Óptica y OptometríaTRUEBMWi - Bundesministerium für Wirtschaft und Energie (Alemania)AEI/MCIN/10.13039/501100011033Ministerio de ciencia e innovación de EspañaInstituto Astrofísico de Andalucía (España)Agencia Estatal de Investigación (España)Fondo Europeo de Desarrollo Regional (Fondos FEDER)Centre national d'études spatiales (CNES) (Francia)CSIC (Centro Superior de Investigaciones Científicas) (España)pu
Autoantibodies against MHC class I polypeptide-related sequence A are associated with increased risk of concomitant autoimmune diseases in celiac patients
Background: Overexpression of autologous proteins can lead to the formation of autoantibodies and autoimmune diseases. MHC class I polypeptide-related sequence A (MICA) is highly expressed in the enterocytes of patients with celiac disease, which arises in response to gluten. The aim of this study was to investigate anti-MICA antibody formation in patients with celiac disease and its association with other autoimmune processes. Methods: We tested serum samples from 383 patients with celiac disease, obtained before they took up a gluten-free diet, 428 patients with diverse autoimmune diseases, and 200 controls for anti-MICA antibodies. All samples were also tested for anti-endomysium and anti-transglutaminase antibodies. Results: Antibodies against MICA were detected in samples from 41.7% of patients with celiac disease but in only 3.5% of those from controls (P <0.0001) and 8.2% from patients with autoimmune disease (P <0.0001). These antibodies disappeared after the instauration of a gluten-free diet. Anti-MICA antibodies were significantly prevalent in younger patients (P <0.01). Fifty-eight patients with celiac disease (15.1%) presented a concomitant autoimmune disease. Anti-MICA-positive patients had a higher risk of autoimmune disease than MICA antibody-negative patients (P <0.0001; odds ratio = 6.11). The risk was even higher when we also controlled for age (odds ratio = 11.69). Finally, we found that the associated risk of developing additional autoimmune diseases was 16 and 10 times as high in pediatric patients and adults with anti-MICA, respectively, as in those without. Conclusions: The development of anti-MICA antibodies could be related to a gluten-containing diet, and seems to be involved in the development of autoimmune diseases in patients with celiac disease, especially younger ones
Polymorphisms in DNA-repair genes in a cohort of prostate cancer patients from different areas in Spain: heterogeneity between populations as a confounding factor in association studies
Background: Differences in the distribution of genotypes between individuals of the same ethnicity are an important confounder factor commonly undervalued in typical association studies conducted in radiogenomics. Objective: To evaluate the genotypic distribution of SNPs in a wide set of Spanish prostate cancer patients for determine the homogeneity of the population and to disclose potential bias. Design, Setting, and Participants: A total of 601 prostate cancer patients from Andalusia, Basque Country, Canary and Catalonia were genotyped for 10 SNPs located in 6 different genes associated to DNA repair: XRCC1 (rs25487, rs25489, rs1799782), ERCC2 (rs13181), ERCC1 (rs11615), LIG4 (rs1805388, rs1805386), ATM (rs17503908, rs1800057) and P53 (rs1042522). The SNP genotyping was made in a Biotrove OpenArrayH NT Cycler. Outcome Measurements and Statistical Analysis: Comparisons of genotypic and allelic frequencies among populations, as well as haplotype analyses were determined using the web-based environment SNPator. Principal component analysis was made using the SnpMatrix and XSnpMatrix classes and methods implemented as an R package. Non-supervised hierarchical cluster of SNP was made using MultiExperiment Viewer. Results and Limitations: We observed that genotype distribution of 4 out 10 SNPs was statistically different among the studied populations, showing the greatest differences between Andalusia and Catalonia. These observations were confirmed in cluster analysis, principal component analysis and in the differential distribution of haplotypes among the populations. Because tumor characteristics have not been taken into account, it is possible that some polymorphisms may influence tumor characteristics in the same way that it may pose a risk factor for other disease characteristics. Conclusion: Differences in distribution of genotypes within different populations of the same ethnicity could be an important confounding factor responsible for the lack of validation of SNPs associated with radiation-induced toxicity, especially when extensive meta-analysis with subjects from different countries are carried out
The effect of perceived discrimination on the health of immigrant workers in Spain
Background: Discrimination is an important determinant of health inequalities, and immigrants may be more vulnerable to certain types of discrimination than the native-born. This study analyses the relationship between immigrants' perceived discrimination and various self-reported health indicators. Methods: A cross-sectional survey was conducted (2008) amongst a non-random sample of 2434 immigrants from Ecuador, Morocco, Romania and Colombia in four Spanish cities: Barcelona, Huelva, Madrid and Valencia. A factorial analysis of variables revealed three dimensions of perceived discrimination (due to immigrant status, due to physical appearance, and workplace-related). The association of these dimensions with self-rated health, mental health (GHQ-12), change in self-rated health between origin and host country, and other self-reported health outcomes was analysed. Logistic regression was used adjusting for potential confounders (aOR-95%CI). Subjects with worsening self-reported health status potentially attributable to perceived discrimination was estimated (population attributable proportion, PAP %). Results: 73.3% of men and 69.3% of women immigrants reported discrimination due to immigrant status. Moroccans showed the highest prevalence of perceived discrimination. Immigrants reporting discrimination were at significantly higher risk of reporting health problems than those not reporting discrimination. Workplace-related discrimination was associated with poor mental health (aOR 2.97 95%CI 2.45-3.60), and the worsening of self-rated health (aOR 2.20 95%CI 1.73- 2.80). 40% (95% CI 24-53) PAP of those reporting worse self-rated health could be attributable to discrimination due to immigrant status. Conclusions: Discrimination may constitute a risk factor for health in immigrant workers in Spain and could explain some health inequalities among immigrant populations in Spanish society.This work was supported by the following sources: Carolina Foundation (Spain), Healthcare Research Fund of the Spanish Ministry of Health and Consumption (references PI050497, PI052202, PI052334, PI061701, and PI0790470
- …