122 research outputs found

    Association of Osteocalcin and Abdominal Aortic Calcification in Older Women: The Study of Osteoporotic Fractures

    Get PDF
    Osteocalcin (OC) is produced by osteoblasts and vascular smooth muscle cells. In animal models, serum OC levels are strongly correlated with vascular calcium content, however, the association of OC with vascular calcification in humans is uncertain. The Study of Osteoporotic Fractures (SOF) enrolled community-living women, age ≥65 years. The present study included a subsample of 363 randomly selected SOF participants. Serum total OC was measured by ELISA, and abdominal aortic calcification (AAC) was evaluated on lateral lumbar radiographs. We examined the cross-sectional association between serum OC and AAC. The mean serum OC level was 24 ± 11 ng/ml and AAC was present in 188 subjects (52%). We observed no association of OC and AAC in either unadjusted or adjusted analyses. For example, each standard deviation higher OC level was associated with an odds ratio (OR) for AAC prevalence (AAC score >0) near unity (OR = 1.06; 95% CI, 0.82–1.36) in models adjusted for CVD risk factors. Further adjustment for intact parathyroid hormone, bone-specific alkaline phosphatase, 25-hydroxyvitamin D, and hip and spine bone mineral density did not materially change the results (OR = 1.22; 95% CI, 0.86–1.75). Similarly, higher OC levels were not associated with severity of AAC (P = 0.87). In conclusion, among community-living older women, serum OC is not associated with AAC. These findings suggest that serum OC levels may more closely reflect bone formation than vascular calcification in humans

    Excess cardiovascular risk in diabetic women: a case for intensive treatment.

    Get PDF
    Diabetes is a common and rapidly growing disease that affects more than 380 million people worldwide and is an established risk factor for cardiovascular disease with differential effects on women compared to men. While the general population of women, particularly young women, has more favourable cardiovascular risk profiles than men, this protective effect has been shown to be lost or even reversed in diabetic women. Several studies have demonstrated a significant diabetes-associated excess risk of cardiovascular disease in women. Sex-specific differences in risk factors associated with diabetes and their management may be responsible for the relative excess cardiovascular risk in women with diabetes. Diabetic women need intensive treatment in order to optimize management of cardiovascular risk factors. Further studies are needed to elucidate the mechanisms underlying the excess cardiovascular risk in diabetic women in order to tailor prevention and treatment strategies

    Graphene oxide deposition on neodymium doped zinc borotellurite glass surface: optical and polarizability study for future fiber optics

    Get PDF
    Neodymium oxide doped tellurite-based glass has been widely documented for potential uses in optoelectronics, but graphene oxide (GO)-coated tellurite-based glass has rarely been reported. In this work, we compare two sets of glass series which were GO-coated and uncoated tellurite-based glass series denoted as ZBTNd-GO and ZBTNd, respectively. The two sets of glasses were fabricated via melt-quenched process. A set of glass was coated with GO using low-cost spray coating method. The structural and morphological properties of the glass samples were investigated to confirm the type of structure in glass and formation of graphene oxide on glass surface. The X-ray diffraction (XRD) pattern confirmed the amorphous structural arrangement in both sets of glass series. The morphological study proved the existence of GO layers on top of the ZBTNd-GO surface. The optical bandgap energy of ZBTNd-GO glass was found in the range of 3.253 eV–3.381 eV which was higher than ZBTNd glass. Meanwhile, the refractive index of ZBTNd-GO glass varies from 2.301 to 2.332 which was higher than ZBTNd glass due to the presence of functionalized oxygenated groups in GO structure. The oxide ion polarizability of ZBTNd-GO glass was found decreased due to the shift of optical band gap when coated with GO. This work offers a new form of glass that could be used as a new strategy to upgrade the current photonic materials

    A Genome-Scale DNA Repair RNAi Screen Identifies SPG48 as a Novel Gene Associated with Hereditary Spastic Paraplegia

    Get PDF
    We have identified a novel gene in a genome-wide, double-strand break DNA repair RNAi screen and show that is involved in the neurological disease hereditary spastic paraplegia

    Global Chronic Total Occlusion Crossing Algorithm: JACC State-of-the-Art Review

    Get PDF
    The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration

    Global Chronic Total Occlusion Crossing Algorithm

    Get PDF
    The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration.info:eu-repo/semantics/publishedVersio
    corecore