642 research outputs found

    The gatekeeper: individual differences are key in the chain from perception to behaviour

    No full text
    A basic assumption in mainstream social cognition is that the path from perception to behaviour is often automatic and direct, as supported for example by several experimental studies showing that priming can lead directly to a congruent behaviour without any need of conscious awareness of the process. However, we argue that the priming of a goal or an object activates individual differences in automatic evaluations at the associative level that in turn are the key predictors of action (gatekeeper model). A study (n = 90) on the American stereotype is presented to support the model. The results show that individual differences of the American stereotype as assessed with the IAT predicts a relevant action (essay evaluation) but only under condition of priming. Broader implications for predictive validity of implicit measures are also discussed

    An x ray archive on your desk: The Einstein CD-ROM's

    Get PDF
    Data from the Einstein Observatory imaging proportional counter (IPC) and high resolution imager (HRI) were released on several CD-ROM sets. The sets released so far include pointed IPC and HRI observations in both simple image and detailed photon event list format, as well as the IPC slew survey. With the data on these CD-ROMS's the user can perform spatial analysis (e.g., surface brightness distributions), spectral analysis (with the IPC event lists), and timing analysis (with the IPC and HRI event lists). The next CD-ROM set will contain IPC unscreened data, allowing the user to perform custom screening to recover, for instance, data during times of lost aspect data or high particle background rates

    Post-treatment FDG PET-CT in head and neck carcinoma: comparative analysis of 4 qualitative interpretative criteria in a large patient cohort

    Get PDF
    There is no consensus regarding optimal interpretative criteria (IC) for Fluorine-18 fluorodeoxyglucose (FDG) Positron Emission Tomography – Computed Tomography (PET-CT) response assessment following (chemo)radiotherapy (CRT) for head and neck squamous cell carcinoma (HNSCC). The aim was to compare accuracy of IC (NI-RADS, Porceddu, Hopkins, Deauville) for predicting loco-regional control and progression free survival (PFS). All patients with histologically confirmed HNSCC treated at a specialist cancer centre with curative-intent non-surgical treatment who underwent baseline and response assessment FDG PET-CT between August 2008 and May 2017 were included. Metabolic response was assessed using 4 different IC harmonised into 4-point scales (complete response, indeterminate, partial response, progressive disease). IC performance metrics (sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy) were compared. Kaplan-Meier and Cox proportional hazards regression analyses were performed for survival analysis. 562 patients were included (397 oropharynx, 53 hypopharynx, 48 larynx, 64 other/unknown primary). 420 patients (75%) received CRT and 142 (25%) had radiotherapy alone. Median follow-up was 26 months (range 3–148). 156 patients (28%) progressed during follow-up. All IC were accurate for prediction of primary tumour (mean NPV 85.0% (84.6–85.3), PPV 85.0% (82.5–92.3), accuracy 84.9% (84.2–86.0)) and nodal outcome (mean NPV 85.6% (84.1–86.6), PPV 94.7% (93.8–95.1), accuracy 86.8% (85.6–88.0)). Number of indeterminate scores for NI-RADS, Porceddu, Deauville and Hopkins were 91, 25, 20, 13 and 55, 70, 18 and 3 for primary tumour and nodes respectively. PPV was significantly reduced for indeterminate uptake across all IC (mean PPV primary tumour 36%, nodes 48%). Survival analyses showed significant differences in PFS between response categories classified by each of the four IC (p <0.001). All four IC have similar diagnostic performance characteristics although Porceddu and Deauville scores offered the best trade off of minimising indeterminate outcomes whilst maintaining a high NPV

    Methods for Estimating Fluxes and Absorptions of Faint X-ray Sources

    Full text link
    X-ray sources with very few counts can be identified with low-noise X-ray detectors such as ACIS onboard the Chandra X-ray Observatory. These sources are often too faint for parametric spectral modeling using well-established methods such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic broad-band X-ray fluxes and soft X-ray absorption from gas along the line of sight to these sources, using nonparametric methods. Apparent flux is estimated from the ratio of the source count rate to the instrumental effective area averaged over the chosen band. Absorption, intrinsic flux, and errors on these quantities are estimated from comparison of source photometric quantities with those of high S/N spectra that were simulated using spectral models characteristic of the class of astrophysical sources under study. The concept of this method is similar to the long-standing use of color-magnitude diagrams in optical and infrared astronomy, with X-ray median energy replacing color index and X-ray source counts replacing magnitude. Our nonparametric method is tested against the apparent spectra of 2000 faint sources in the Chandra observation of the rich young stellar cluster in the M17 HII region. We show that the intrinsic X-ray properties can be determined with little bias and reasonable accuracy using these observable photometric quantities without employing often uncertain and time-consuming methods of non-linear parametric spectral modeling. Our method is calibrated for thermal spectra characteristic of stars in young stellar clusters, but recalibration should be possible for some other classes of faint X-ray sources such as extragalactic AGN.Comment: Accepted for publication in The Astrophysical Journal. 39 pages, 15 figure

    Probing the X-Ray Binary Populations of the Ring Galaxy NGC 1291

    Get PDF
    We present Chandra studies of the X-ray binary (XRB) populations in the bulge and ring regions of the ring galaxy NGC 1291. We detect 169 X-ray point sources in the galaxy, 75 in the bulge and 71 in the ring, utilizing the four available Chandra observations totaling an effective exposure of 179 ks. We report photometric properties of these sources in a point-source catalog. There are ~40% of the bulge sources and ~25% of the ring sources showing >3\sigma long-term variability in their X-ray count rate. The X-ray colors suggest that a significant fraction of the bulge (~75%) and ring (~65%) sources are likely low-mass X-ray binaries (LMXBs). The spectra of the nuclear source indicate that it is a low-luminosity AGN with moderate obscuration; spectral variability is observed between individual observations. We construct 0.3-8.0 keV X-ray luminosity functions (XLFs) for the bulge and ring XRB populations, taking into account the detection incompleteness and background AGN contamination. We reach 90% completeness limits of ~1.5\times10^{37} and ~2.2\times10^{37} erg/s for the bulge and ring populations, respectively. Both XLFs can be fit with a broken power-law model, and the shapes are consistent with those expected for populations dominated by LMXBs. We perform detailed population synthesis modeling of the XRB populations in NGC 1291, which suggests that the observed combined XLF is dominated by an old LMXB population. We compare the bulge and ring XRB populations, and argue that the ring XRBs are associated with a younger stellar population than the bulge sources, based on the relative overdensity of X-ray sources in the ring, the generally harder X-ray color of the ring sources, the overabundance of luminous sources in the combined XLF, and the flatter shape of the ring XLF.Comment: 15 pages, 11 figures. Accepted for publication in Ap

    Effect of metallicity on the gravitational-wave signal from the cosmological population of compact binary coalescences

    Full text link
    Recent studies on stellar evolution have shown that the properties of compact objects strongly depend on the metallicity of the environment in which they were formed. Using some very simple assumptions on the metallicity of the stellar populations, we explore how this property affects the unresolved gravitational-wave background from extragalactic compact binaries. We obtained a suit of models using population synthesis code, estimated the gravitational-wave background they produce, and discuss its detectability with second- (advanced LIGO, advanced Virgo) and third- (Einstein Telescope) generation detectors. Our results show that the background is dominated by binary black holes for all considered models in the frequency range of terrestrial detectors, and that it could be detected in most cases by advanced LIGO/Virgo, and with Einstein Telescope with a very high signal-to-noise ratio. The observed peak in a gravitational wave spectrum depends on the metallicity of the stellar population.Comment: 9 pages, 5 figures, accepted to A&

    X-ray and Radio Variability of M31*, The Andromeda Galaxy Nuclear Supermassive Black Hole

    Get PDF
    We confirm our earlier tentative detection of M31* in X-rays and measure its light-curve and spectrum. Observations in 2004-2005 find M31* rather quiescent in the X-ray and radio. However, X-ray observations in 2006-2007 and radio observations in 2002 show M31* to be highly variable at times. A separate variable X-ray source is found near P1, the brighter of the two optical nuclei. The apparent angular Bondi radius of M31* is the largest of any black hole, and large enough to be well resolved with Chandra. The diffuse emission within this Bondi radius is found to have an X-ray temperature ~0.3 keV and density 0.1 cm-3, indistinguishable from the hot gas in the surrounding regions of the bulge given the statistics allowed by the current observations. The X-ray source at the location of M31* is consistent with a point source and a power law spectrum with energy slope 0.9+/-0.2. Our identification of this X-ray source with M31* is based solely on positional coincidence.Comment: 25 pages, 8 figures, submitted to Ap

    The Chandra Local Volume Survey: The X-ray Point Source Catalog of NGC 300

    Full text link
    We present the source catalog of a new Chandra ACIS-I observation of NGC 300 obtained as part of the Chandra Local Volume Survey. Our 63 ks exposure covers ~88% of the D25 isophote (R~6.3 kpc) and yields a catalog of 95 X-ray point sources detected at high significance to a limiting unabsorbed 0.35-8 keV luminosity of ~10^36 erg s^-1. Sources were cross-correlated with a previous XMM-Newton catalog, and we find 75 "X-ray transient candidate" sources that were detected by one observatory, but not the other. We derive an X-ray scale length of 1.7+/-0.2 kpc and a recent star formation rate of 0.12 Msun yr^-1, in excellent agreement with optical observations. Deep, multi-color imaging from the Hubble Space Telescope, covering ~32% of our Chandra field, was used to search for optical counterparts to the X-ray sources, and we have developed a new source classification scheme to determine which sources are likely X-ray binaries, supernova remnants, and background AGN candidates. Finally, we present the X-ray luminosity functions (XLFs) at different X-ray energies, and we find the total NGC 300 X-ray point source population to be consistent with other late-type galaxies hosting young stellar populations (<50 Myr). We find XLF of sources associated with older stellar populations has a steeper slope than the XLF of X-ray sources coinciding with young stellar populations, consistent with theoretical predictions.Comment: 23 pages, 13 figures. Accepted to Ap
    • …
    corecore