642 research outputs found
The gatekeeper: individual differences are key in the chain from perception to behaviour
A basic assumption in mainstream social cognition is that the path from perception to behaviour is often automatic and direct, as supported for example by several experimental studies showing that priming can lead directly to a congruent behaviour without any need of conscious awareness of the process. However, we argue that the priming of a goal or an object activates individual differences in automatic evaluations at the associative level that in turn are the key predictors of action (gatekeeper model). A study (n = 90) on the American stereotype is presented to support the model. The results show that individual differences of the American stereotype as assessed with the IAT predicts a relevant action (essay evaluation) but only under condition of priming. Broader implications for predictive validity of implicit measures are also discussed
An x ray archive on your desk: The Einstein CD-ROM's
Data from the Einstein Observatory imaging proportional counter (IPC) and high resolution imager (HRI) were released on several CD-ROM sets. The sets released so far include pointed IPC and HRI observations in both simple image and detailed photon event list format, as well as the IPC slew survey. With the data on these CD-ROMS's the user can perform spatial analysis (e.g., surface brightness distributions), spectral analysis (with the IPC event lists), and timing analysis (with the IPC and HRI event lists). The next CD-ROM set will contain IPC unscreened data, allowing the user to perform custom screening to recover, for instance, data during times of lost aspect data or high particle background rates
Post-treatment FDG PET-CT in head and neck carcinoma: comparative analysis of 4 qualitative interpretative criteria in a large patient cohort
There is no consensus regarding optimal interpretative criteria (IC) for Fluorine-18 fluorodeoxyglucose (FDG) Positron Emission Tomography – Computed Tomography (PET-CT) response assessment following (chemo)radiotherapy (CRT) for head and neck squamous cell carcinoma (HNSCC). The aim was to compare accuracy of IC (NI-RADS, Porceddu, Hopkins, Deauville) for predicting loco-regional control and progression free survival (PFS). All patients with histologically confirmed HNSCC treated at a specialist cancer centre with curative-intent non-surgical treatment who underwent baseline and response assessment FDG PET-CT between August 2008 and May 2017 were included. Metabolic response was assessed using 4 different IC harmonised into 4-point scales (complete response, indeterminate, partial response, progressive disease). IC performance metrics (sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy) were compared. Kaplan-Meier and Cox proportional hazards regression analyses were performed for survival analysis. 562 patients were included (397 oropharynx, 53 hypopharynx, 48 larynx, 64 other/unknown primary). 420 patients (75%) received CRT and 142 (25%) had radiotherapy alone. Median follow-up was 26 months (range 3–148). 156 patients (28%) progressed during follow-up. All IC were accurate for prediction of primary tumour (mean NPV 85.0% (84.6–85.3), PPV 85.0% (82.5–92.3), accuracy 84.9% (84.2–86.0)) and nodal outcome (mean NPV 85.6% (84.1–86.6), PPV 94.7% (93.8–95.1), accuracy 86.8% (85.6–88.0)). Number of indeterminate scores for NI-RADS, Porceddu, Deauville and Hopkins were 91, 25, 20, 13 and 55, 70, 18 and 3 for primary tumour and nodes respectively. PPV was significantly reduced for indeterminate uptake across all IC (mean PPV primary tumour 36%, nodes 48%). Survival analyses showed significant differences in PFS between response categories classified by each of the four IC (p <0.001). All four IC have similar diagnostic performance characteristics although Porceddu and Deauville scores offered the best trade off of minimising indeterminate outcomes whilst maintaining a high NPV
Methods for Estimating Fluxes and Absorptions of Faint X-ray Sources
X-ray sources with very few counts can be identified with low-noise X-ray
detectors such as ACIS onboard the Chandra X-ray Observatory. These sources are
often too faint for parametric spectral modeling using well-established methods
such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic
broad-band X-ray fluxes and soft X-ray absorption from gas along the line of
sight to these sources, using nonparametric methods. Apparent flux is estimated
from the ratio of the source count rate to the instrumental effective area
averaged over the chosen band. Absorption, intrinsic flux, and errors on these
quantities are estimated from comparison of source photometric quantities with
those of high S/N spectra that were simulated using spectral models
characteristic of the class of astrophysical sources under study. The concept
of this method is similar to the long-standing use of color-magnitude diagrams
in optical and infrared astronomy, with X-ray median energy replacing color
index and X-ray source counts replacing magnitude. Our nonparametric method is
tested against the apparent spectra of 2000 faint sources in the Chandra
observation of the rich young stellar cluster in the M17 HII region. We show
that the intrinsic X-ray properties can be determined with little bias and
reasonable accuracy using these observable photometric quantities without
employing often uncertain and time-consuming methods of non-linear parametric
spectral modeling. Our method is calibrated for thermal spectra characteristic
of stars in young stellar clusters, but recalibration should be possible for
some other classes of faint X-ray sources such as extragalactic AGN.Comment: Accepted for publication in The Astrophysical Journal. 39 pages, 15
figure
Probing the X-Ray Binary Populations of the Ring Galaxy NGC 1291
We present Chandra studies of the X-ray binary (XRB) populations in the bulge
and ring regions of the ring galaxy NGC 1291. We detect 169 X-ray point sources
in the galaxy, 75 in the bulge and 71 in the ring, utilizing the four available
Chandra observations totaling an effective exposure of 179 ks. We report
photometric properties of these sources in a point-source catalog. There are
~40% of the bulge sources and ~25% of the ring sources showing >3\sigma
long-term variability in their X-ray count rate. The X-ray colors suggest that
a significant fraction of the bulge (~75%) and ring (~65%) sources are likely
low-mass X-ray binaries (LMXBs). The spectra of the nuclear source indicate
that it is a low-luminosity AGN with moderate obscuration; spectral variability
is observed between individual observations. We construct 0.3-8.0 keV X-ray
luminosity functions (XLFs) for the bulge and ring XRB populations, taking into
account the detection incompleteness and background AGN contamination. We reach
90% completeness limits of ~1.5\times10^{37} and ~2.2\times10^{37} erg/s for
the bulge and ring populations, respectively. Both XLFs can be fit with a
broken power-law model, and the shapes are consistent with those expected for
populations dominated by LMXBs. We perform detailed population synthesis
modeling of the XRB populations in NGC 1291, which suggests that the observed
combined XLF is dominated by an old LMXB population. We compare the bulge and
ring XRB populations, and argue that the ring XRBs are associated with a
younger stellar population than the bulge sources, based on the relative
overdensity of X-ray sources in the ring, the generally harder X-ray color of
the ring sources, the overabundance of luminous sources in the combined XLF,
and the flatter shape of the ring XLF.Comment: 15 pages, 11 figures. Accepted for publication in Ap
Recommended from our members
The use of electron beams for pasteurization of meats
Electron beam accelerators can be used for electronic pasteurization of meat products by: (1) using the electrons directly impacting the products, or (2) optimizing the conversion of electron energy to x-rays and treating the product with these x-rays. The choice of process depends on the configuration of the product when it is treated. For electron treatment, ten million electron volt (MeV) kinetic energy is the maximum allowed by international agreement. The depth of penetration of electrons with that energy into a product with density of meat is about five centimeters (cm). Two-sided treatment can be done on products up to 10 cm thick with a two-to-one ratio between minimum and maximum dose. Ground beef patties are about 1.25 cm (0.5 inch thick). Beams with 2.5 MeV electron energy could be used to treat these products. Our calculations show that maximum to minimum dose ratios less than 1.2 can be achieved with this energy if the transverse beam energy is small. If the product thickness is greater than 10 cm, x-rays can provide the needed dose uniformity. Uniform doses can be supplied for pallets with dimensions greater than 1.2 m on each side using x-rays from a 5 MeV electron beam. The efficiency of converting the electron beam to x-rays and configurations to achieve dose uniformity are discussed
Effect of metallicity on the gravitational-wave signal from the cosmological population of compact binary coalescences
Recent studies on stellar evolution have shown that the properties of compact
objects strongly depend on the metallicity of the environment in which they
were formed. Using some very simple assumptions on the metallicity of the
stellar populations, we explore how this property affects the unresolved
gravitational-wave background from extragalactic compact binaries. We obtained
a suit of models using population synthesis code, estimated the
gravitational-wave background they produce, and discuss its detectability with
second- (advanced LIGO, advanced Virgo) and third- (Einstein Telescope)
generation detectors. Our results show that the background is dominated by
binary black holes for all considered models in the frequency range of
terrestrial detectors, and that it could be detected in most cases by advanced
LIGO/Virgo, and with Einstein Telescope with a very high signal-to-noise ratio.
The observed peak in a gravitational wave spectrum depends on the metallicity
of the stellar population.Comment: 9 pages, 5 figures, accepted to A&
X-ray and Radio Variability of M31*, The Andromeda Galaxy Nuclear Supermassive Black Hole
We confirm our earlier tentative detection of M31* in X-rays and measure its
light-curve and spectrum. Observations in 2004-2005 find M31* rather quiescent
in the X-ray and radio. However, X-ray observations in 2006-2007 and radio
observations in 2002 show M31* to be highly variable at times. A separate
variable X-ray source is found near P1, the brighter of the two optical nuclei.
The apparent angular Bondi radius of M31* is the largest of any black hole, and
large enough to be well resolved with Chandra. The diffuse emission within this
Bondi radius is found to have an X-ray temperature ~0.3 keV and density 0.1
cm-3, indistinguishable from the hot gas in the surrounding regions of the
bulge given the statistics allowed by the current observations. The X-ray
source at the location of M31* is consistent with a point source and a power
law spectrum with energy slope 0.9+/-0.2. Our identification of this X-ray
source with M31* is based solely on positional coincidence.Comment: 25 pages, 8 figures, submitted to Ap
The Chandra Local Volume Survey: The X-ray Point Source Catalog of NGC 300
We present the source catalog of a new Chandra ACIS-I observation of NGC 300
obtained as part of the Chandra Local Volume Survey. Our 63 ks exposure covers
~88% of the D25 isophote (R~6.3 kpc) and yields a catalog of 95 X-ray point
sources detected at high significance to a limiting unabsorbed 0.35-8 keV
luminosity of ~10^36 erg s^-1. Sources were cross-correlated with a previous
XMM-Newton catalog, and we find 75 "X-ray transient candidate" sources that
were detected by one observatory, but not the other. We derive an X-ray scale
length of 1.7+/-0.2 kpc and a recent star formation rate of 0.12 Msun yr^-1, in
excellent agreement with optical observations. Deep, multi-color imaging from
the Hubble Space Telescope, covering ~32% of our Chandra field, was used to
search for optical counterparts to the X-ray sources, and we have developed a
new source classification scheme to determine which sources are likely X-ray
binaries, supernova remnants, and background AGN candidates. Finally, we
present the X-ray luminosity functions (XLFs) at different X-ray energies, and
we find the total NGC 300 X-ray point source population to be consistent with
other late-type galaxies hosting young stellar populations (<50 Myr). We find
XLF of sources associated with older stellar populations has a steeper slope
than the XLF of X-ray sources coinciding with young stellar populations,
consistent with theoretical predictions.Comment: 23 pages, 13 figures. Accepted to Ap
- …