263 research outputs found

    Emotion matters: Different psychophysiological responses to expressive and non-expressive full-body movements

    Get PDF
    We explore dance video clip stimuli as a means to test human observers' accuracy in detecting genuine emotional expressivity in full-body movements. Stimuli of every-day-type full-body expressions of emotions usually use culturally very recognizable actions (e.g. fist shaking for anger, etc). However, expressive dance movement stimuli can be created to contain fully abstract movements. The expressivity results from subtle variations in the body movements of the expressor, and emotions cannot be recognised by observers via particular actions (e.g. fist shaking, etc). Forty-one participants watched and rated 24 pairs of short dance videos –from a published normalised dance stimuli library– in randomised order (N = 48). Of each carefully matched pair, one version of the full-body movement sequence had been danced to be emotionally genuinely expressive (clip a), while the other version of the same sequence (clip b) had been danced –while technically correct– without any emotional expressivity. Participants rated (i) expressivity (to test their accuracy; block 1), and (ii) how much they liked each movement (an implicit measure to test their emotional response (“liking”); block 2). Participants rated clips that were intended to be expressive as more expressive (part 1: expressivity ratings), and liked those expressive clips more than the non-expressive clips (part 2: liking ratings). Besides, their galvanic skin response differed, depending on the category of clips they were watching (expressive vs. non-expressive), and this relationship was modulated by interceptive accuracy and arts experience. Results are discussed in relation to the Body Precision Hypothesis and the Hypothesis of Constructed Emotion

    Detection of Salmonella enterica in meat in less than 5 hours by a low-cost and non-complex sample preparation method

    Get PDF
    Salmonella is recognized as one of the most important foodborne bacteria and has wide health and socioeconomic impacts worldwide. Fresh pork meat is one of the main sources of Salmonella, and efficient and fast methods for detection are therefore necessary. Current methods for Salmonella detection in fresh meat usually include >16 h of culture enrichment, in a few cases <12 h, thus requiring at least two working shifts. Here, we report a rapid (<5 h) and high-throughput method for screening of Salmonella in samples from fresh pork meat, consisting of a 3-h enrichment in standard buffered peptone water and a real-time PCR-compatible sample preparation method based on filtration, centrifugation, and enzymatic digestion, followed by fast-cycling real-time PCR detection. The method was validated in an unpaired comparative study against the Nordic Committee on Food Analysis (NMKL) reference culture method 187. Pork meat samples (n = 140) were either artificially contaminated with Salmonella at 0, 1 to 10, or 10 to 100 CFU/25 g of meat or naturally contaminated. Cohen's kappa for the degree of agreement between the rapid method and the reference was 0.64, and the relative accuracy, sensitivity, and specificity for the rapid method were 81.4, 95.1, and 97.9%, respectively. The 50% limit of detections (LOD(50)s) were 8.8 CFU/25 g for the rapid method and 7.7 CFU/25 g for the reference method. Implementation of this method will enable faster release of Salmonella low-risk meat, providing savings for meat producers, and it will help contribute to improved food safety. IMPORTANCE While the cost of analysis and hands-on time of the presented rapid method were comparable to those of reference culture methods, the fast product release by this method can provide the meat industry with a competitive advantage. Not only will the abattoirs save costs for work hours and cold storage, but consumers and retailers will also benefit from fresher meat with a longer shelf life. Furthermore, the presented sample preparation might be adjusted for application in the detection of other pathogenic bacteria in different sample types

    I just lost it! Fear and anger reduce the sense of agency: a study using intentional binding

    Get PDF
    Two recent studies have demonstrated that increases in arousal states lead to an increase people’s sense of agency, i.e., the subjective experience of controlling one’s own voluntary actions (Minohara et al. in Front Psychol 7:1165, 2016; Wen et al. in Conscious Cogn 36:87–95, 2015). We here extend these findings by showing that arousal states with negative emotional valence, such as fear and anger, decrease sense of agency. Anger and fear are negative emotional states. Anecdotally, they are often invoked as reasons for losing control, and neuroscientific evidence confirms important effects on the brain’s action control systems. Surprisingly, the subjective experience of acting in anger or fear has scarcely been investigated experimentally. Thus, the legal notion that these intense emotions may undermine normal voluntary control over actions and outcomes (the ‘Loss of Control’, a partial defence for murder) lacks any clear evidence base. In three laboratory experiments, we measured sense of agency using an implicit measure based on time perception (the “intentional binding” paradigm). These actions occurred in either an emotionally neutral condition, or in a fearful (experiments 1 and 2) or angry state (experiment 3). In line with our hypotheses, fear or anger reduced the subjective sense of control over an action outcome, even though the objective causal link between action and outcome remained the same. This gap between the objective facts of agency, and a reduced subjective experience of agency under emotional conditions, has important implications for society and law

    NuSTAR on-ground calibration: I. Imaging quality

    Get PDF
    The Nuclear Spectroscopic Telescope Array (NuSTAR) launched in June 2012 carries the first focusing hard Xray (5 - 80 keV) telescope to orbit. The on-ground calibration was performed at the RaMCaF facility at Nevis, Columbia University. During the assembly of the telescopes, mechanical surface metrology provided surface maps of the reflecting surfaces. Several flight coated mirrors were brought to BNL for scattering measurements. The information from both sources is fed to a raytracing code that is tested against the on-ground calibration data. The code is subsequently used for predicting the imaging properties for X-ray sources at infinite distance

    Histological assessment of paxgene tissue fixation and stabilization reagents

    Get PDF
    Within SPIDIA, an EC FP7 project aimed to improve pre analytic procedures, the PAXgene Tissue System (PAXgene), was designed to improve tissue quality for parallel molecular and morphological analysis. Within the SPIDIA project promising results were found in both genomic and proteomic experiments with PAXgene-fixed and paraffin embedded tissue derived biomolecules. But, for this technology to be accepted for use in both clinical and basic research, it is essential that its adequacy for preserving morphology and antigenicity is validated relative to formalin fixation. It is our aim to assess the suitability of PAXgene tissue fixation for (immuno)histological methods. Normal human tissue specimens (n = 70) were collected and divided into equal parts for fixation either with formalin or PAXgene. Sections of the obtained paraffin-embedded tissue were cut and stained. Morphological aspects of PAXgene-fixed tissue were described and also scored relative to formalin-fixed tissue. Performance of PAXgene-fixed tissue in immunohistochemical and in situ hybridization assays was also assessed relative to the corresponding formalin-fixed tissues. Morphology of PAXgene-fixed paraffin embedded tissue was well preserved and deemed adequate for diagnostics in most cases. Some antigens in PAXgene-fixed and paraffin embedded sections were detectable without the need for antigen retrieval, while others were detected using standard, formalin fixation based, immunohistochemistry protocols. Comparable results were obtained with in situ hybridization and histochemical stains. Basically all assessed histological techniques were found to be applicable to PAXgene-fixed and paraffin embedded tissue. In general results obtained with PAXgene-fixed tissue are comparable to those of formalin-fixed tissue. Compromises made in morphology can be called minor compared to the advantages in the molecular pathology possibilities

    Timing and flux evolution of the galactic center magnetar SGR J1745–2900

    Get PDF
    We present the X-ray timing and spectral evolution of the Galactic Center magnetar SGR J1745–2900 for the first ∌4 months post-discovery using data obtained with the Nuclear Spectroscopic Telescope Array and Swift observatories. Our timing analysis reveals a large increase in the magnetar spin-down rate by a factor of 2.60 ± 0.07 over our data span. We further show that the change in spin evolution was likely coincident with a bright X-ray burst observed in 2013 June by Swift, and if so, there was no accompanying discontinuity in the frequency. We find that the source 3-10 keV flux has declined monotonically by a factor of ∌2 over an 80 day period post-outburst accompanied by a ∌20% decrease in the source's blackbody temperature, although there is evidence for both flux and kT having leveled off. We argue that the torque variations are likely to be magnetospheric in nature and will dominate over any dynamical signatures of orbital motion around Sgr A*

    Examination of Late Palaeolithic archaeological sites in northern Europe for the preservation of cryptotephra layers

    Get PDF
    We report the first major study of cryptotephra (non-visible volcanic ash layers) on Late Palaeolithic archaeological sites in northern Europe. Examination of 34 sites dating from the Last Termination reveals seven with identifiable cryptotephra layers. Preservation is observed in minerogenic and organic deposits, although tephra is more common in organic sediments. Cryptotephra layers normally occur stratigraphically above or below the archaeology. Nearby off-site palaeoclimate archives (peat bogs and lakes &lt;0.3 km distant) were better locations for detecting tephra. However in most cases the archaeology can only be correlated indirectly with such cryptotephras. Patterns affecting the presence/absence of cryptotephra include geographic position of sites relative to the emitting volcanic centre; the influence of past atmospherics on the quantity, direction and patterns of cryptotephra transport; the nature and timing of local site sedimentation; sampling considerations and subsequent taphonomic processes. Overall, while tephrostratigraphy has the potential to improve significantly the chronology of such sites many limiting factors currently impacts the successful application
    • 

    corecore