13 research outputs found

    Cross-compensation of FET sensor drift and matrix effects in the industrial continuous monitoring of ion concentrations

    Full text link
    Field-effect transistor (FET) sensors are attractive potentiometric (bio)chemical measurement devices because of their fast response, low output impedance, and potential for miniaturization in standard integrated circuit manufacturing technologies. Yet the wide adoption of these sensors for real-world applications is still limited, mainly due to temporal drift and cross-sensitivities that introduce considerable error in the measurements. In this paper, we demonstrate that such non-idealities can be corrected by joint use of an array of FET sensors – selective to target and major interfering ions – with machine learning (ML) methods in order to accurately predict ion concentrations continuously and in the field. We studied the predictive performance of linear regression (LR), support vector regression (SVR), and state-of-art deep neural networks (DNNs) when monitoring pH from combinatorial H+, Na+, and K+ ion-sensitive FET (ISFET) sequences of readings collected over a period of 90 consecutive days in real water quality assessment conditions. The proposed ML algorithms were trained against reference online measurements obtained from a commercial pH sensor. Results show a greater capability of DNNs to provide precise pH monitoring for longer than a week, achieving a relative root-mean-square error reduction of 73% over standard two-point sensor calibration methods

    Real-time smart multisensing wearable platform for monitoring sweat biomarkers during exercise

    Full text link
    Sweat secreted by the human eccrine sweat glands can provide valuable biomarker information during exercise in hot and humid conditions. Real-time noninvasive biomarker recordings are therefore useful for evaluating the physiological conditions of an athlete such as their hydration status during endurance exercise. In this work, we describe a platform that in- cludes different sweat biomonitoring prototypes of cost-effective, smart wearable devices for continuous biomonitoring of sweat during exercise. One prototype is based on conformable and disposable soft sensing patches with an integrated multi-sensor array requiring the integration of different sensors and printed sensors with their corresponding functionalization protocols on the same substrate. The second is based on silicon based sensors and paper microfluidics. Both platforms integrate a multi-sensor array for measuring sodium, potassium, and pH in sweat. We show preliminary results obtained from the multi-sensor prototypes placed on two athletes during exercise. We also show that the machine learning algorithms can predict the percentage of body weight loss during exercise from biomarkers such as heart rate and sweat sodium concentration collected over multiple subjects

    ISFET Based Microsensors for Environmental Monitoring

    Get PDF
    The use of microsensors for in-field monitoring of environmental parameters is gaining interest due to their advantages over conventional sensors. Among them microsensors based on semiconductor technology offer additional advantages such as small size, robustness, low output impedance and rapid response. Besides, the technology used allows integration of circuitry and multiple sensors in the same substrate and accordingly they can be implemented in compact probes for particular applications e.g., in situ monitoring and/or on-line measurements. In the field of microsensors for environmental applications, Ion Selective Field Effect Transistors (ISFETs) have a special interest. They are particularly helpful for measuring pH and other ions in small volumes and they can be integrated in compact flow cells for continuous measurements. In this paper the technologies used to fabricate ISFETs and a review of the role of ISFETs in the environmental field are presented

    Canagliflozin and renal outcomes in type 2 diabetes and nephropathy

    Get PDF
    BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to <90 ml per minute per 1.73 m2 of body-surface area and albuminuria (ratio of albumin [mg] to creatinine [g], >300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of <15 ml per minute per 1.73 m2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P<0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P<0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years

    Spermine-induced hybridization and charge inversion at the diffuse layer of a DNA-FET

    No full text
    Detection of DNA hybridization events by using field-effect transducers is limited by the electrolyte content of the medium. So far, DNA was thought to hybridize only in solutions with concentrated electrolytes. In these media, the interface between the transducer gate and the solution is reduced to a thin layer in close contact with the surface, and DNA is poorly detected. In the present work, this limitation is overcome by using spermine as screening polycation. Hybridization assays with polycation concentrations as low as 10 mu M are reported. This ensures that hybridization takes place at the diffuse layer of the interface. The reported results suggest a charge-inversion mechanism induced by spermine. A target sequence is real-time label-free detected in the range from 10 to 500 nM

    Chemical sensor network for pH monitoring

    Get PDF
    Monitoring of water sources is a major concern worldwide. Wireless sensor networks (WSN) may be used for this monitoring. However, current systems employ mainly physical sensors for variables such as temperature, pressure, humidity and light. Wireless chemical sensors networks (WCSNs) for environmental monitoring are scarce due to the lack of autonomy of conventional sensors. This paper presents results of a WCSN for monitoring pH based on ion selective field effect transistors (ISFETs). Sensing nodes employ a human interface required for in situ calibration of chemical sensors. Unlike most studies, our work evaluates the network employing chemical measurements and wireless network metrics. Results show zero packet losses by using a time division multiple access (TDMA) protocol. The network allows wireless communication within 300 m including attenuation from buildings and trees. Therefore, the system presented in this paper is suitable for long range applications with unobstructed line of sight. pH measurements present a standard deviation below 1%, showing high repeatability. When compared to a commercial pH meter, difference in measurements is below 5%. As a consequence, accuracy is adequate for the application. Measurements also presented high stability during 3 h of continuous measurement

    Thin-film electrochemical sensor for diphenylamine detection using molecularly imprinted polymers

    No full text
    This work reports on the development of a new voltammetric sensor for diphenylamine based on the use of a miniaturized gold electrode modified with a molecularly imprinted polymer recognition element. Molecularly imprinted particles were synthesized ex situ and further entrapped into a poly(3,4-ethylenedioxythiophene) polymer membrane, which was electropolymerized on the surface of the gold electrode. The thickness of the polymer layer was optimized in order to get an adequate diffusion of the target analyte and in turn to achieve an adequate charge transfer at the electrode surface. The resulting modified electrodes showed a selective response to diphenylamine and a high sensitivity compared with the bare gold electrode and the electrode modified with poly(3,4-ethylenedioxythiophene) and non-imprinted polymer particles. The sensor showed a linear range from 4.95 to 115. ÎĽM diphenylamine, a limit of detection of 3.9. ÎĽM and a good selectivity in the presence of other structurally related molecules. This sensor was successfully applied to the quantification of diphenylamine in spiked apple juice samples

    A new device for simple and accurate urinary pH testing by the Stone-former patient

    Get PDF
    Abstract Purpose Urinary pH is an important factor linked to renal stone disease and a useful marker in the treatment of urolithiasis. Although the gold standard for measuring urinary pH utilizes a glass electrode and a pH meter, at present dipstick testing is largely used to estimate urinary pH. However, the accuracy and precision of this method may be insufficient for making clinical decisions in patients with lithiasis. The aim of this study is to describe a new device for urinary pH testing. Methods The device includes a pH sensor based on differential measurement of an ISFET-REFET pair. The drawbacks associated with this type of configuration, namely short lifetime and manual fabrication, have been overcome in the prototype. An automatic one point calibration is performed when turning on the system. Two buffer solutions were utilized to determine the intra- and inter-day precision of the device. The pH of 30 fresh human urine samples was measured using a pH-meter, a dipstick and the new electronic device. Results In some cases, dipstick measurements differed from those of the pH meter by more than 0.40 units, a clinically relevant discrepancy, whereas none of the measurements made with the new electronic device differed from the results of the pH-meter by more than 0.1 pH units. Conclusions This new electronic device has the possibility to be used by stone-formers to control their urinary pH at home, increasing the tools available for stone prevention and prophylaxis.This work was supported by the project grants CTQ2010-18271/PPQ and TEC2010-19467 from the Ministerio de Ciencia e Innovación (Gobierno de España), FEDER funds (European Union) and the project grant 9/2011 from the Conselleria d’Educació, Cultura i Universitat (Govern de les Illes Balears).Peer Reviewe