59 research outputs found
The Unseen Population of F to K-type Companions to Hot Subdwarf Stars
We present a method to select hot subdwarf stars with A to M-type companions
using photometric selection criteria. We cover a wide range in wavelength by
combining GALEX ultraviolet data, optical photometry from the SDSS and the
Carlsberg Meridian telescope, near-infrared data from 2MASS and UKIDSS. We
construct two complimentary samples, one by matching GALEX, CMC and 2MASS, as
well as a smaller, but deeper, sample using GALEX, SDSS and UKIDSS. In both
cases, a large number of composite subdwarf plus main-sequence star candidates
were found. We fit their spectral energy distributions with a composite model
in order to estimate the subdwarf and companion star effective temperatures
along with the distance to each system. The distribution of subdwarf effective
temperature was found to primarily lie in the 20,000 - 30,000 K regime, but we
also find cooler subdwarf candidates, making up ~5-10 per cent. The most
prevalent companion spectral types were seen to be main-sequence stars between
F0 and K0, while subdwarfs with M-type companions appear much rarer. This is
clear observational confirmation that a very efficient first stable Roche-lobe
overflow channel appears to produce a large number of subdwarfs with F to
K-type companions. Our samples thus support the importance of binary evolution
for subdwarf formation.Comment: 30 pages, 10 figures, 11 tables. Accepted for publication in MNRA
Periodic and Quasiperiodic Motion of an Elongated Microswimmer in Poiseuille Flow
We study the dynamics of a prolate spheroidal microswimmer in Poiseuille flow
for different flow geometries. When moving between two parallel plates or in a
cylindrical microchannel, the swimmer performs either periodic swinging or
periodic tumbling motion. Although the trajectories of spherical and elongated
swimmers are qualitatively similar, the swinging and tumbling frequency
strongly depends on the aspect ratio of the swimmer. In channels with reduced
symmetry the swimmers perform quasiperiodic motion which we demonstrate
explicitely for swimming in a channel with elliptical cross section
The Rough Guide to In Silico Function Prediction, or How To Use Sequence and Structure Information To Predict Protein Function
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
The LUX-ZEPLIN (LZ) experiment is a dark matter detector centered on a
dual-phase xenon time projection chamber operating at the Sanford Underground
Research Facility in Lead, South Dakota, USA. This Letter reports results from
LZ's first search for Weakly Interacting Massive Particles (WIMPs) with an
exposure of 60 live days using a fiducial mass of 5.5 t. A profile-likelihood
ratio analysis shows the data to be consistent with a background-only
hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent
WIMP-neutron, and spin-dependent WIMP-proton cross-sections for WIMP masses
above 9 GeV/c. The most stringent limit is set at 30 GeV/c, excluding
cross sections above 5.9 cm at the 90\% confidence level.Comment: 9 pages, 6 figures. See https://tinyurl.com/LZDataReleaseRun1 for a
data release related to this pape
The LUX-ZEPLIN (LZ) Experiment
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements
Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study
Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P < 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P < 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk
The LUX-ZEPLIN (LZ) experiment
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850’ level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4×10−48cm2 for a WIMP mass of 40GeV/c2 and a 1000days exposure. LZ achieves this sensitivity through a combination of a large 5.6t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented
- …