18 research outputs found

    Assessing plant performance in the Enviratron

    Get PDF
    Background: Assessing the impact of the environment on plant performance requires growing plants under controlled environmental conditions. Plant phenotypes are a product of genotype × environment (G × E), and the Enviratron at Iowa State University is a facility for testing under controlled conditions the effects of the environment on plant growth and development. Crop plants (including maize) can be grown to maturity in the Enviratron, and the performance of plants under different environmental conditions can be monitored 24 h per day, 7 days per week throughout the growth cycle. Results: The Enviratron is an array of custom-designed plant growth chambers that simulate different environmental conditions coupled with precise sensor-based phenotypic measurements carried out by a robotic rover. The rover has workflow instructions to periodically visit plants growing in the different chambers where it measures various growth and physiological parameters. The rover consists of an unmanned ground vehicle, an industrial robotic arm and an array of sensors including RGB, visible and near infrared (VNIR) hyperspectral, thermal, and time-of-flight (ToF) cameras, laser profilometer and pulse-amplitude modulated (PAM) fluorometer. The sensors are autonomously positioned for detecting leaves in the plant canopy, collecting various physiological measurements based on computer vision algorithms and planning motion via “eye-in-hand” movement control of the robotic arm. In particular, the automated leaf probing function that allows the precise placement of sensor probes on leaf surfaces presents a unique advantage of the Enviratron system over other types of plant phenotyping systems. Conclusions: The Enviratron offers a new level of control over plant growth parameters and optimizes positioning and timing of sensor-based phenotypic measurements. Plant phenotypes in the Enviratron are measured in situ—in that the rover takes sensors to the plants rather than moving plants to the sensors

    Evacetrapib and Cardiovascular Outcomes in High-Risk Vascular Disease

    Get PDF
    BACKGROUND: The cholesteryl ester transfer protein inhibitor evacetrapib substantially raises the high-density lipoprotein (HDL) cholesterol level, reduces the low-density lipoprotein (LDL) cholesterol level, and enhances cellular cholesterol efflux capacity. We sought to determine the effect of evacetrapib on major adverse cardiovascular outcomes in patients with high-risk vascular disease. METHODS: In a multicenter, randomized, double-blind, placebo-controlled phase 3 trial, we enrolled 12,092 patients who had at least one of the following conditions: an acute coronary syndrome within the previous 30 to 365 days, cerebrovascular atherosclerotic disease, peripheral vascular arterial disease, or diabetes mellitus with coronary artery disease. Patients were randomly assigned to receive either evacetrapib at a dose of 130 mg or matching placebo, administered daily, in addition to standard medical therapy. The primary efficacy end point was the first occurrence of any component of the composite of death from cardiovascular causes, myocardial infarction, stroke, coronary revascularization, or hospitalization for unstable angina. RESULTS: At 3 months, a 31.1% decrease in the mean LDL cholesterol level was observed with evacetrapib versus a 6.0% increase with placebo, and a 133.2% increase in the mean HDL cholesterol level was seen with evacetrapib versus a 1.6% increase with placebo. After 1363 of the planned 1670 primary end-point events had occurred, the data and safety monitoring board recommended that the trial be terminated early because of a lack of efficacy. After a median of 26 months of evacetrapib or placebo, a primary end-point event occurred in 12.9% of the patients in the evacetrapib group and in 12.8% of those in the placebo group (hazard ratio, 1.01; 95% confidence interval, 0.91 to 1.11; P=0.91). CONCLUSIONS: Although the cholesteryl ester transfer protein inhibitor evacetrapib had favorable effects on established lipid biomarkers, treatment with evacetrapib did not result in a lower rate of cardiovascular events than placebo among patients with high-risk vascular disease. (Funded by Eli Lilly; ACCELERATE ClinicalTrials.gov number, NCT01687998 .)

    Assessing plant performance in the Enviratron

    No full text
    Background: Assessing the impact of the environment on plant performance requires growing plants under controlled environmental conditions. Plant phenotypes are a product of genotype × environment (G × E), and the Enviratron at Iowa State University is a facility for testing under controlled conditions the effects of the environment on plant growth and development. Crop plants (including maize) can be grown to maturity in the Enviratron, and the performance of plants under different environmental conditions can be monitored 24 h per day, 7 days per week throughout the growth cycle. Results: The Enviratron is an array of custom-designed plant growth chambers that simulate different environmental conditions coupled with precise sensor-based phenotypic measurements carried out by a robotic rover. The rover has workflow instructions to periodically visit plants growing in the different chambers where it measures various growth and physiological parameters. The rover consists of an unmanned ground vehicle, an industrial robotic arm and an array of sensors including RGB, visible and near infrared (VNIR) hyperspectral, thermal, and time-of-flight (ToF) cameras, laser profilometer and pulse-amplitude modulated (PAM) fluorometer. The sensors are autonomously positioned for detecting leaves in the plant canopy, collecting various physiological measurements based on computer vision algorithms and planning motion via “eye-in-hand” movement control of the robotic arm. In particular, the automated leaf probing function that allows the precise placement of sensor probes on leaf surfaces presents a unique advantage of the Enviratron system over other types of plant phenotyping systems. Conclusions: The Enviratron offers a new level of control over plant growth parameters and optimizes positioning and timing of sensor-based phenotypic measurements. Plant phenotypes in the Enviratron are measured in situ—in that the rover takes sensors to the plants rather than moving plants to the sensors.This article is published as Bao, Yin, Scott Zarecor, Dylan Shah, Taylor Tuel, Darwin A. Campbell, Antony VE Chapman, David Imberti, Daniel Kiekhaefer, Henry Imberti, Thomas LĂŒbberstedt, Yanhai Yin, Dan Nettleton, Carolyn J. Lawrence‑Dill, Steven A. Whitham, Lie Tang, and Stephen H. Howell. "Assessing plant performance in the Enviratron." Plant Methods 15, no. 1 (2019): 117. DOI: 10.1186/s13007-019-0504-y. Posted with permission.</p

    Management of bleeding and reversal strategies for oral anticoagulants: Clinical practice considerations

    No full text
    PURPOSE: Currently available clinical data and optimal strategies for reversing oral anticoagulants in patients who are bleeding or need an urgent invasive procedure or operation are reviewed. SUMMARY: Bleeding from oral anticoagulants, including new target-specific oral agents (TSOAs), is a common cause of morbidity and mortality, especially in elderly patients. Limited clinical data are available to guide the reversal of warfarin or TSOAs in patients who are bleeding or need an urgent invasive procedure or operation. A panel of five experts with diverse backgrounds in anticoagulation therapy, cardiology, critical care, and emergency medicine and with experience in managing complications of anticoagulation therapy was convened to develop practical strategies for managing patients receiving oral anticoagulants who are bleeding or have an urgent need for an invasive procedure. The strategies were designed to guide clinicians in the acute care setting by providing efficient and potentially effective management concepts to avoid delays in initiating treatment that could adversely affect patient outcomes. The consensus of this expert panel is summarized herein. Recommendations are based on currently available evidence from a comprehensive review of the literature and other pertinent data, along with the experience and expert opinion of the panelists. CONCLUSION: Bleeding is a serious complication of the use of oral anticoagulants, and limited information is available to guide the reversal of warfarin or TSOAs in patients who are bleeding or are in need of an urgent invasive procedure. Use of a systematic approach to assessing and treating these patients based on available evidence and expert opinion can help avoid delays that could adversely affect patient outcomes
    corecore