91 research outputs found

    Effect of water immersion temperature on heart rate variability following exercise in the heat

    Get PDF
    This study compared the effect of passive rest (CON) and water immersion at 8.6±0.2°C (CWI9), 14.6±0.3°C (CWI15) and 35.0±0.4°C (thermoneutral water immersion [TWI]) on post-exercise heart rate variability (HRV) indices. In a climate chamber (32.8±0.4°C, 32±5% relative humidity), nine men completed 25 min of cycling at the first ventilatory threshold and repeated 30-second bouts at 90% of peak power followed by a 5-minute recovery treatment in a randomised crossover manner. All water immersion re-established the HRV indices (natural logarithm of the square root of the mean sum squared differences between RR intervals [ln rMSSD], low-frequency [lnLF] and high-frequency power densities [lnHF] and Poincaré plotderived measures [lnSD1 and lnSD2]) to the pre-exercise levels at 60 min post-immersion; however, only CWI9 accelerated parasympathetic reactivation during immersion. CWI9 increased lnLF and lnSD2 during immersion when compared with CON (p\u3c.05). Although CWI9 had a large positive effect size (ES\u3e0.80) on all HRV indices during immersion when compared with CON, between-conditions differences were observed only in lnLF and lnSD2 (p=.017-.023). CWI15 had a large positive ES on ln rMSSD and lnSD1 when compared with CON (both p=.064). Sympathovagal antagonism (i.e., SD ratio\u3c0.15) did not occur during CWI9 and CWI15. Hence, both CWI treatments are effective means of enhancing post-exercise parasympathetic reactivation, but CWI9 is likely to be more effective at increasing post-exercise cardiac vagal tone

    Effect of water immersion temperature on heart rate variability following exercise in the heat

    Get PDF
    This study compared the effect of passive rest (CON) and water immersion at 8.6±0.2°C (CWI9), 14.6±0.3°C (CWI15) and 35.0±0.4°C (thermoneutral water immersion [TWI]) on post-exercise heart rate variability (HRV) indices. In a climate chamber (32.8±0.4°C, 32±5% relative humidity), nine men completed 25 min of cycling at the first ventilatory threshold and repeated 30-second bouts at 90% of peak power followed by a 5-minute recovery treatment in a randomised crossover manner. All water immersion re-established the HRV indices (natural logarithm of the square root of the mean sum squared differences between RR intervals [ln rMSSD], low-frequency [lnLF] and high-frequency power densities [lnHF] and Poincaré plotderived measures [lnSD1 and lnSD2]) to the pre-exercise levels at 60 min post immersion; however, only CWI9 accelerated parasympathetic reactivation during immersion. CWI9 increased lnLF and lnSD2 during immersion when compared with CON (p0.80) on all HRV indices during immersion when compared with CON, between-conditions differences were observed only in lnLF and lnSD2 (p=.017-.023). CWI15 had a large positive ES on ln rMSSD and lnSD1 when compared with CON (both p=.064). Sympathovagal antagonism (i.e., SD ratio<0.15) did not occur during CWI9 and CWI15. Hence, both CWI treatments are effective means of enhancing post-exercise parasympathetic reactivation, but CWI9 is likely to be more effective at increasing post-exercise cardiac vagal tone

    Effect of ice slushy ingestion and cold water immersion on thermoregulatory behavior

    Get PDF
    Two studies were conducted to examine the effects of ice slushy ingestion (ICE) and cold water immersion (CWI) on thermoregulatory and sweat responses during constant (study 1) and self-paced (study 2) exercise. In study 1, 11 men cycled at 40–50% of peak aerobic power for 60 min (33.2 ± 0.3C, 45.9 ± 0.5% relative humidity, RH). In study 2, 11 men cycled for 60 min at perceived exertion (RPE) equivalent to 15 (33.9 ± 0.2C and 42.5 ± 3.9%RH). In both studies, each trial was preceded by 30 min of CWI (~22C), ICE or no cooling (CON). Rectal temperature (T re ), skin temperature (T sk ), thermal sensation, and sweat responses were measured. In study 1, ICE decreased T re- T sk gradient versus CON (p = 0.005) during first 5 min of exercise, while CWI increased T re- T sk gradient versus CON and ICE for up to 20 min during the exercise (p0.05). Increased T re -T sk gradient by CWI improved MPO while ICE reduced T re but did not confer any ergogenic effect. Both precooling treatments attenuated the thermal efferent signals until a specific body temperature threshold was reached. © 2019 Choo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

    Riverine sustainment 2012

    Get PDF
    Student Integrated ProjectIncludes supplementary materialThis technical report analyzed the Navy's proposed Riverine Force (RF) structure and capabilities for 2012. The Riverine Sustainment 2012 Team (RST) examined the cost and performance of systems of systems which increased RF sustainment in logistically barren environments. RF sustainment was decomposed into its functional areas of supply, repair, and force protection. The functional and physical architectures were developed in parallel and were used to construct an operational architecture for the RF. The RST used mathematical, agent-based and queuing models to analyze various supply, repair and force protection system alternatives. Extraction of modeling data revealed several key insights. Waterborne heavy lift connectors such as the LCU-2000 are vital in the re-supply of the RF when it is operating up river in a non-permissive environment. Airborne heavy lift connectors such as the MV-22 were ineffective and dominated by the waterborne variants in the same environment. Increase in manpower and facilities did appreciable add to the operational availability of the RF. Mean supply response time was the biggest factor effecting operational availability and should be kept below 24 hours to maintain operational availability rates above 80%. Current mortar defenses proposed by the RF are insufficient.N

    Numerical study on load-bearing capabilities of beam-like lattice structures with three different unit cells

    Get PDF
    The design and analysis of lattice structures manufactured using Additive Manufacturing (AM) technique is a new approach to create lightweight high-strength components. However, it is difficult for engineers to choose the proper unit cell for a certain function structure and loading case. In this paper, three beam-like lattice structures with triangular prism, square prism and hexagonal prism were designed, manufactured by SLM process using AlSi10Mg and tested. The mechanical performances of lattice structures with equal relative density, equal base area and height, and equal length for all unit cells were conducted by Finite Element Analysis (FEA). It was found that effective Young’s modulus is proportional to relative density, but with different affecting levels. When the lattice structures are designed with the same relative density or the same side lengths, the effective Young’s modulus of lattice structure with triangular prism exhibits the maximum value for both cases. When the lattice structures are designed with the same base areas for all unit cells, the effective Young’s modulus of lattice structures with square prism presents the maximum. FEA results also show that the maximum stress of lattice structures with triangular prisms in each comparison is at the lowest level and the stiffness-to-mass ratio remains at the maximum value, showing the overwhelming advantages in terms of mechanical strength. The excellent agreements between numerical results and experimental tests reveal the validity of FEA methods applied. The results in this work provide an explicit guideline to fabricate beam-like lattice structures with the best tensile and bending capabilities

    GDTN: Genome-Based Delay Tolerant Network Formation in Heterogeneous 5G Using Inter-UA Collaboration

    Get PDF
    This work was supported by ‘The Cross-Ministry Giga KOREA Project’ grant from the Ministry of Science, ICT and Future Planning, Korea. Also, it was in part supported by the Soonchunhyang University Research Fund.With a more Internet-savvy and sophisticated user base, there are more demands for interactive applications and services. However, it is a challenge for existing radio access networks (e.g. 3G and 4G) to cope with the increasingly demanding requirements such as higher data rates and wider coverage area. One potential solution is the inter-collaborative deployment of multiple radio devices in a 5G setting designed to meet exacting user demands, and facilitate the high data rate requirements in the underlying networks. These heterogeneous 5G networks can readily resolve the data rate and coverage challenges. Networks established using the hybridization of existing networks have diverse military and civilian applications. However, there are inherent limitations in such networks such as irregular breakdown, node failures, and halts during speed transmissions. In recent years, there have been attempts to integrate heterogeneous 5G networks with existing ad hoc networks to provide a robust solution for delay-tolerant transmissions in the form of packet switched networks. However, continuous connectivity is still required in these networks, in order to efficiently regulate the flow to allow the formation of a robust network. Therefore, in this paper, we present a novel network formation consisting of nodes from different network maneuvered by Unmanned Aircraft (UA). The proposed model utilizes the features of a biological aspect of genomes and forms a delay tolerant network with existing network models. This allows us to provide continuous and robust connectivity. We then demonstrate that the proposed network model has an efficient data delivery, lower overheads and lesser delays with high convergence rate in comparison to existing approaches, based on evaluations in both real-time testbed and simulation environment.Yeshttp://www.plosone.org/static/editorial#pee

    Screening ethnically diverse human embryonic stem cells identifies a chromosome 20 minimal amplicon conferring growth advantage

    Get PDF
    The International Stem Cell Initiative analyzed 125 human embryonic stem (ES) cell lines and 11 induced pluripotent stem (iPS) cell lines, from 38 laboratories worldwide, for genetic changes occurring during culture. Most lines were analyzed at an early and late passage. Single-nucleotide polymorphism (SNP) analysis revealed that they included representatives of most major ethnic groups. Most lines remained karyotypically normal, but there was a progressive tendency to acquire changes on prolonged culture, commonly affecting chromosomes 1, 12, 17 and 20. DNA methylation patterns changed haphazardly with no link to time in culture. Structural variants, determined from the SNP arrays, also appeared sporadically. No common variants related to culture were observed on chromosomes 1, 12 and 17, but a minimal amplicon in chromosome 20q11.21, including three genes expressed in human ES cells, ID1, BCL2L1 and HM13, occurred in >20% of the lines. Of these genes, BCL2L1 is a strong candidate for driving culture adaptation of ES cells

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P &lt; 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P &lt; 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk
    corecore