306 research outputs found

    Whole Body Screening Using High-Temperature Superconducting MR Volume Resonators: Mice Studies

    Get PDF
    High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal. In this study, a whole new Bi2Sr2Ca2Cu2O3 (Bi-2223) superconducting saddle resonator (width of 5 cm and length of 8 cm) was designed for the magnetic resonance image of a mouse's whole body in Bruker 3 T MRI system. The experiment was conducted with a professionally-made copper saddle resonator and a Bi-2223 saddle resonator to show the difference. Signal-to-noise ratio (SNR) with the HTS saddle resonator at 77 K was 2.1 and 2 folds higher than that of the copper saddle resonator at 300 K for a phantom and an in-vivo mice whole body imaging. Testing results were in accordance with predicted ones, and the difference between the predicted SNR gains and measured SNR gains were 2.4%∼2.7%. In summary, with this HTS saddle system, a mouse's whole body can be imaged in one scan and could reach a high SNR due to a 2 folds SNR gain over the professionally-made prototype of copper saddle resonator at 300 K. The use of HTS saddle resonator not only improves SNR but also enables a mouse's whole body screen in one scan

    Magnetic field independence of the spin gap in YBa_2Cu_3O_{7-delta}

    Full text link
    We report, for magnetic fields of 0, 8.8, and 14.8 Tesla, measurements of the temperature dependent ^{63}Cu NMR spin lattice relaxation rate for near optimally doped YBa_2Cu_3O_{7-delta}, near and above T_c. In sharp contrast with previous work we find no magnetic field dependence. We discuss experimental issues arising in measurements of this required precision, and implications of the experiment regarding issues including the spin or pseudo gap.Comment: 4 pages, 3 figures, as accepted for publication in Physical Review Letter

    Signal enhancement in protein NMR using the spin-noise tuning optimum

    Get PDF
    We have assessed the potential of an alternative probe tuning strategy based on the spin-noise response for application in common high-resolution multi-dimensional biomolecular NMR experiments with water signal suppression on aqueous and salty samples. The method requires the adjustment of the optimal tuning condition, which may be offset by several 100 kHz from the conventional tuning settings using the noise response of the water protons as an indicator. Although the radio frequency-pulse durations are typically longer under such conditions, signal-to-noise gains of up to 22% were achieved. At salt concentrations up to 100 mM a substantial sensitivity gain was observed

    Current CONtrolled Transmit And Receive Coil Elements (C2ONTAR) for Parallel Acquisition and Parallel Excitation Techniques at High-Field MRI

    Get PDF
    A novel intrinsically decoupled transmit and receive radio-frequency coil element is presented for applications in parallel imaging and parallel excitation techniques in high-field magnetic resonance imaging. Decoupling is achieved by a twofold strategy: during transmission elements are driven by current sources, while during signal reception resonant elements are switched to a high input impedance preamplifier. To avoid B0 distortions by magnetic impurities or DC currents a resonant transmission line is used to relocate electronic components from the vicinity of the imaged object. The performance of a four-element array for 3 T magnetic resonance tomograph is analyzed by means of simulation, measurements of electromagnetic fields and bench experiments. The feasibility of parallel acquisition and parallel excitation is demonstrated and compared to that of a conventional power source-driven array of equivalent geometry. Due to their intrinsic decoupling the current-controlled elements are ideal basic building blocks for multi-element transmit and receive arrays of flexible geometry

    When learning becomes a fetish: the pledge, turn and prestige of magic tricks

    Get PDF
    It is our contention that the process of higher education could be read as a commodity and in both Marxian and Freudian assumptions, a fetish. Instrumental in this discussion are; Marx’s theorising of the commodity fetish (1867) that deceives by conflating the distinction between use and exchange value, and Freud’s (1927) re-visiting of his theory of fetishism, where he considers the fetish in the context of dealing with separation and loss in everyday life. This paper highlights how the consequence of fetishised behaviour has led to violent outcomes, such as the policy decision to introduce a ‘Teaching Excellence Framework’ (TEF). We argue that the TEF may bring about the death of learning in HE and diminish the role of academic staff. Nevertheless, influenced by Winnicott, Cixous and Biesta, we offer a more hopeful ‘Teaching that is Good Enough Framework’

    Nuclear Magnetic Resonance Imaging with 90 nm Resolution

    Full text link
    Magnetic resonance imaging, based on the manipulation and detection of nuclear spins, is a powerful imaging technique that typically operates on the scale of millimeters to microns. Using magnetic resonance force microscopy, we have demonstrated that magnetic resonance imaging of nuclear spins can be extended to a spatial resolution better than 100 nm. The two-dimensional imaging of 19F nuclei was done on a patterned CaF2 test object, and was enabled by a detection sensitivity of roughly 1200 nuclear spins. To achieve this sensitivity, we developed high-moment magnetic tips that produced field gradients up to 1.4x10^6 T/m, and implemented a measurement protocol based on force-gradient detection of naturally occurring spin fluctuations. The resulting detection volume of less than 650 zl represents 60,000x smaller volume than previous NMR microscopy and demonstrates the feasibility of pushing magnetic resonance imaging into the nanoscale regime.Comment: 24 pages, 5 figure

    Rapid Detection of Infestation of Apple Fruits by the Peach Fruit Moth, Carposina sasakii Matsumura, Larvae Using a 0.2-T Dedicated Magnetic Resonance Imaging Apparatus

    Get PDF
    Infestation of harvested apple fruits by the peach fruit moth (Carposina sasakii Matsumura) was studied using a dedicated magnetic resonance imaging (MRI) apparatus equipped with a 0.2-T permanent magnet. Infested holes on the three-dimensional (3-D) images tracked ecological movements of peach fruit moth larvae within the food fruits, and thus in their natural habitat. Sensitive short solenoid coil and surface coil detectors were devised to shorten measurement times. The short solenoid coil detected infestation holes at a rate of 6.4 s per image by the single-slice 2-D measurement. The multi-slice 2-D measurement provided six slice images of a fruit within 2 min taken by the two detectors. These results indicate that the 0.2-T MRI apparatus allows one to distinguish sound fruits from infested ones, and also as a means for plant protection and the preservation of natural ecological systems in foreign trade

    Sheep Updates 2006 - part 4

    Get PDF
    This session covers seven papers from different authors: MANAGEMENT 1. Wool and meat traits in Merino flocks in different regions, K.G. Geenty, A.A. Swan, A.J. Smith, J.L. Smith, Sheep CRC and CSIRO Livestock Industries, Armidale 2. Fat score or Condition score? - It all depends on what you want to do! Chris Oldham, Department of Agriculture and Food Western Australia 3. Sheep worm control - the latest for Western Australia, RG Woodgate, RA Love, E Dobbe, HM Hoult, J Pearson, S Hill, A van Burgel and RB Besier, Department of Agriculture and Food Western Australia PASTURES 4. Rethinking pasture production - STEPS to greater productivity with perennials, R. Warburton, Farmer, Mobrup, WA, L. Mathwin, Farmer Kojonup WA, D. Rogers, E. Crossley, Department of Agriculture and Food Western Australia 5. Sheep Returnes from Saltland Pastures, Allan Herbert, Department of Agriculture and Food Western Australia 6. Pasture legumes and grasses from saline land, Phil Nichols, Tony Albertsen, Darryl McClements, Department of Agriculture and Food Western Australia, & Cooperative Research Centre for Plant-based Management of Dryland Salinity MERINO INNOVATION DAY 7. Towards \u27clean, green and ethical\u27 sheep production, Graeme Martin, Penny Hawken, Carolina Viñoles, Beth Paganoni and Dominique Blache, School of Animal Biology, Faculty of Natural & Agricultural Sciences, The University of Western Australi

    Synchronous diversification of Sulawesi’s iconic artiodactyls driven by recent geological events

    Get PDF
    The high degree of endemism on Sulawesi has previously been suggested to have vicariant origins, dating back 40 Myr ago. Recent studies, however, suggest that much of Sulawesi’s fauna assembled over the last 15 Myr. Here, we test the hypothesis that more recent uplift of previously submerged portions of land on Sulawesi promoted diversification, and that much of its faunal assemblage is much younger than the island itself. To do so, we combined palaeogeographical reconstructions with genetic and morphometric data sets derived from Sulawesi’s three largest mammals: the Babirusa, Anoa, and Sulawesi warty pig. Our results indicate that although these species most likely colonized the area that is now Sulawesi at different times (14 Myr ago to 2-3 Myr ago), they experienced an almost synchronous expansion from the central part of the island. Geological reconstructions indicate that this area was above sea level for most of the last 4 Myr, unlike most parts of the island. We conclude that emergence of land on Sulawesi (~1–2 Myr) may have allowed species to expand synchronously. Altogether, our results indicate that the establishment of the highly endemic faunal assemblage on Sulawesi was driven by geological events over the last few million years

    Identification of Cellular Infiltrates during Early Stages of Brain Inflammation with Magnetic Resonance Microscopy

    Get PDF
    A comprehensive view of brain inflammation during the pathogenesis of autoimmune encephalomyelitis can be achieved with the aid of high resolution non-invasive imaging techniques such as microscopic magnetic resonance imaging (μMRI). In this study we demonstrate the benefits of cryogenically-cooled RF coils to produce μMRI in vivo, with sufficient detail to reveal brain pathology in the experimental autoimmune encephalomyelitis (EAE) model. We could visualize inflammatory infiltrates in detail within various regions of the brain, already at an early phase of EAE. Importantly, this pathology could be seen clearly even without the use of contrast agents, and showed excellent correspondence with conventional histology. The cryogenically-cooled coil enabled the acquisition of high resolution images within short scan times: an important practical consideration in conducting animal experiments. The detail of the cellular infiltrates visualized by in vivo μMRI allows the opportunity to follow neuroinflammatory processes even during the early stages of disease progression. Thus μMRI will not only complement conventional histological examination but will also enable longitudinal studies on the kinetics and dynamics of immune cell infiltration
    corecore