219 research outputs found

    Breastfeeding and risk for ceasing in mothers of preterm infants-long-term follow-up

    Get PDF
    Breastfeeding is challenging for mothers of preterm infants. The aim of this paper is to describe risk factors for ceasing breastfeeding and methods of feeding until 12 months postnatal age in mothers who breastfed their preterm infants at discharge from neonatal intensive care units (NICUs). The data come from a randomised controlled trial, which evaluated the effectiveness on exclusive breastfeeding at 8 weeks of proactive telephone support compared to reactive support offered to mothers of preterm infants following discharge from NICU. Six NICUs across Sweden randomised a total 493 mothers. We used regression and survival analyses to assess the risk factors for ceasing breastfeeding and the long-term outcomes of the intervention. The results showed that 305 (64%) of the infants were breastfed at six months and 49 (21%) at 12 months. Partial breastfeeding at discharge, low maternal educational level and longer length of stay in the NICU increased the risk for ceasing breastfeeding during the first 12 months. Furthermore, the Kaplan-Meier analysis showed that the proportion of mothers who ceased breastfeeding did not differ between the intervention (n=231) and controls (n=262) during the first 12 months (Log rank test p=0.68). No difference was found between groups on method of feeding. More than 85% of the infants were fed directly at the breast. These findings provide important insights for health professionals who are supporting mothers of preterm infants to breastfeed long-term. Registered in www.clinicaltrials.gov (NCT01806480)

    Treatment Trials for Neonatal Seizures : The Effect of Design on Sample Size

    Get PDF
    Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (T-d) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7-40.0) across a range of AED protocols, Td and trial AED efficacy (pPeer reviewe

    Neonatal cerebral function monitoring – understanding the amplitude integrated EEG

    Get PDF
    Amplitude integrated electroencephalography (aEEG) is produced by cerebral function monitors (CFM), and is increasingly used in neonates following research into hypothermia for hypoxic ischaemic encephalopathy in term infants. Formal training packages in aEEG in term infants are limited. aEEG is used less often in clinical practice in preterm infants, and requires an understanding of the normal changes seen with increasing gestational age. A number of classifications for aEEG interpretation exist; some purely for term neonates born, and others encompassing both preterm and term neonates. This article reviews the basics of aEEG, its indications and limitations. We also discuss its role in prognostication in term and preterm infants

    Investigation of EEG activity compared with mean arterial blood pressure in extremely preterm infants

    Get PDF
    BackgroundCerebral electrical activity in extremely preterm infants is affected by various factors including blood gas and circulatory parameters.ObjectiveTo investigate whether continuously measured invasive mean arterial blood pressure (BP) is associated with electroencephalographic (EEG) discontinuity in extremely preterm infants.Study designThis prospective observational study examined 51 newborn infants born <29 weeks gestation in the first 3 days after birth. A single channel of raw EEG was used to quantify discontinuity. Mean BP was acquired using continuous invasive measurement and Doppler ultrasound was used to measure left ventricular output (LVO) and common carotid artery blood flow (CCAF).ResultsMedian gestation and birthweight were 25.6 weeks and 760 g, respectively. Mean discontinuity reduced significantly between days 1 and 3. EEG discontinuity was significantly related to gestation, pH and BP. LVO and CCAF were not associated with EEG discontinuity.ConclusionContinuously measured invasive mean arterial BP was found to have a negative relationship with EEG discontinuity; increasing BP was associated with lower EEG discontinuity. This did not appear to be mediated by surrogates of systemic or cerebral blood flow. Infants receiving inotropic support had significantly increased EEG discontinuity on the first day after birth

    Why monitor the neonatal brain-that is the important question

    Get PDF
    A key goal of neonatal neurocritical care is improved outcomes, and brain monitoring plays an essential role. The recent NEST trial(1) reported no outcome benefits using aEEG monitoring compared to clinical seizure identification among neonates treated for seizures. However, the study failed to prove the effects of monitoring on seizure treatment in the first place.Non peer reviewe

    Prevalence and etiology of false normal aEEG recordings in neonatal hypoxic-ischaemic encephalopathy.

    Get PDF
    BACKGROUND: Amplitude-integrated electroencephalography (aEEG) is a useful tool to determine the severity of neonatal hypoxic-ischemic encephalopathy (HIE). Our aim was to assess the prevalence and study the origin of false normal aEEG recordings based on 85 aEEG recordings registered before six hours of age. METHODS: Raw EEG recordings were reevaluated retrospectively with Fourier analysis to identify and describe the frequency patterns of the raw EEG signal, in cases with inconsistent aEEG recordings and clinical symptoms. Power spectral density curves, power (P) and median frequency (MF) were determined using the raw EEG. In 7 patients non-depolarizing muscle relaxant (NDMR) exposure was found. The EEG sections were analyzed and compared before and after NDMR administration. RESULTS: The reevaluation found that the aEEG was truly normal in 4 neonates. In 3 neonates, high voltage electrocardiographic (ECG) artifacts were found with flat trace on raw EEG. High frequency component (HFC) was found as a cause of normal appearing aEEG in 10 neonates. HFC disappeared while P and MF decreased significantly upon NDMR administration in each observed case. CONCLUSION: Occurrence of false normal aEEG background pattern is relatively high in neonates with HIE and hypothermia. High frequency EEG artifacts suggestive of shivering were found to be the most common cause of false normal aEEG in hypothermic neonates while high voltage ECG artifacts are less common

    Modulation of EEG spectral edge frequency during patterned pneumatic oral stimulation in preterm infants

    Get PDF
    Background—Stimulation of the nervous system plays a central role in brain development and neurodevelopmental outcome. Thalamocortical and corticocortical development is diminished in premature infants and correlated to electroencephalography (EEG) progression. The purpose of this study was to determine the effects of orocutaneous stimulation on the modulation of spectral edge frequency, fc=90% (SEF-90) derived from EEG recordings in preterm infants. Methods—Twenty two preterm infants were randomized to experimental and control conditions. Pulsed orocutaneous stimulation was presented during gavage feedings begun at around 32 weeks postmenstrual age (PMA). The SEF-90 was derived from 2-channel EEG recordings. Results—Compared to the control condition, the pulsed orocutaneous stimulation produced a significant reorganization of SEF-90 in the left (p = 0.005) and right (p \u3c 0.0001) hemispheres. Notably, the left and right hemisphere showed a reversal in the polarity of frequency shift, demonstrating hemispheric asymmetry in the frequency domain. Pulsed orocutaneous stimulation also produced a significant pattern of short term cortical adaptation and a long term neural adaptation manifest as a 0.5 Hz elevation in SEF-90 after repeated stimulation sessions. Conclusion—This is the first study to demonstrate the modulating effects of a servo-controlled oral somatosensory input on the spectral features of EEG activity in preterm infants
    • …
    corecore