111 research outputs found

    Design, construction and testing of a COC 3D flow-over flow-through bioreactor for hepatic cell culture

    Get PDF
    In this poster, we present the joint development efforts for a 3D microfluidic bioreactor for hepatic cell cultures. Cyclic Olefin Copolymer (COC) was selected for constructing the bioreactor, since the material has good chemical resistance, low adsorption and good optical properties, including low auto-fluorescence. A downside of COC is that it is much more difficult to structure than more traditional microfluidic materials, such as PDMS, PMMA, … Two parallel approaches were developed for structuring the COC. In a first approach, mechanical micro-milling of the channels allows for extremely fast manufacturing of new design variations, at the expense of difficulties in scalability to mass-production and a channel surface that requires post-processing to achieve sufficient optical quality. In a second approach, hot embossing using epoxy molds allows for direct structuring of optical grade channels and is scalable to mass production, at the expense of longer cycle time in the development of new channel designs. To facilitate the handling of the bioreactor, a holder was designed to provide the fluidic connections to a pump,ensuring medium exchange and sampling to down-stream sensors connected to the outlets. The design of the bioreactor was intended to maintain and expose pre-formed hepatic co-culture spheroids to toxicants for more than a week. Once seeded, spheroids rest on a polycarbonate membrane with 12 µm pore size, allowing the medium to flow-through, while flow-over is maintained to avoid an excess pressure on the cells. In a single bioreactor, 9 wells are connected to a common inlet to provide the cells with fresh culture medium or test compounds. On a first cell culture trial, it was possible to visually detect the spheroids in the wells after seeding, however, after 1 week of culture there was no possibility to accurately detect the presence and viability of the cells. In the framework of HeMiBio, significant progress has been made towards producing a 3D COC-based bioreactor for hepatic cell culture, and most technological hurdles in producing prototype reactors have been overcome. Further testing is needed to see which improvements to the reactor or the flow conditions should be made to ensure cell viability

    Longitudinal Analysis using Personalised 3D Cardiac Models with Population-Based Priors: Application to Paediatric Cardiomyopathies

    Get PDF
    International audiencePersonalised 3D modelling of the heart is of increasing interest in order to better characterise pathologies and predict evolution. The personalisation consists in estimating the parameter values of an electromechanical model in order to reproduce the observed cardiac motion. However, the number of parameters in these models can be high and their estimation may not be unique. This variability can be an obstacle to further analyse the estimated parameters and for their clinical interpretation. In this paper we present a method to perform consistent estimations of electromechanical parameters with prior probabilities on the estimated values, which we apply on a large database of 84 different heartbeats. We show that the use of priors reduces considerably the variance in the estimated parameters, enabling better conditioning of the parameters for further analysis of the cardiac function. This is demonstrated by the application to longitudinal data of paediatric cardiomyopathies, where the estimated parameters provide additional information on the pathology and its evolution

    Increased copy number at 3p14 in breast cancer

    Get PDF
    INTRODUCTION: The present study was conducted to investigate if chromosome band 3p14 is of any pathogenic significance in the malignant process of breast cancer. Genetic studies have implicated a tumour suppressor gene on chromosome arm 3p and we have proposed LRIG1 at 3p14 as a candidate tumour suppressor. The LRIG1 gene encodes an integral membrane protein that counteracts signalling by receptor tyrosine kinases belonging to the ERBB family. LRIG1 mRNA and protein are expressed in many tissues, including breast tissue. METHODS: In the present report we analysed the LRIG1 gene by fluorescence in situ hybridisation (FISH), LRIG1 mRNA by quantitative RT-PCR, and LRIG1 protein by western blot analysis. Two tumour series were analysed; one series consisted of 19 tumour samples collected between 1987 and 1995 and the other series consisted of 9 tumour samples with corresponding non-neoplastic breast tissues collected consecutively. RESULTS: The LRIG1 gene showed increased copy number in 11 out of 28 tumours (39%) and only one tumour showed a deletion at this locus. Increased LRIG1 copy number was associated with increased levels of LRIG1 mRNA (two of three tumours) and protein (four of four tumours) in the tumours compared to matched non-neoplastic breast tissue, as assessed by RT-PCR and western blot analysis. CONCLUSION: The molecular function of LRIG1 as a negative regulator of ERBB receptors questions the biological significance of increased LRIG1 copy number in breast cancer. We propose that a common, but hitherto unrecognised, breast cancer linked gene is located within an amplicon containing the LRIG1 locus at 3p14.3

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Towards an ideal biomaterial for vitreous replacement: historical overview and future trends

    Get PDF
    corecore