199 research outputs found

    Pupil light reflex evoked by light-emitting diode and computer screen: methodology and association with need for recovery in daily life

    Get PDF
    Objectives: Pupil light reflex (PLR) has been widely used as a method for evaluating parasympathetic activity. The first aim of the present study is to develop a PLR measurement using a computer screen set-up and compare its results with the PLR generated by a more conventional setup using light-emitting diode (LED). The parasympathetic nervous system, which is known to control the ‘rest and digest’ response of the human body, is considered to be associated with daily life fatigue. However, only few studies have attempted to test the relationship between self-reported daily fatigue and physiological measurement of the parasympathetic nervous system. Therefore, the second aim of this study was to investigate the relationship between daily-life fatigue, assessed using the Need for Recovery scale, and parasympathetic activity, as indicated by the PLR parameters. Design: A pilot study was conducted first to develop a PLR measurement set-up using a computer screen. PLRs evoked by light stimuli with different characteristics were recorded to confirm the influence of light intensity, flash duration, and color on the PLRs evoked by the system. In the subsequent experimental study, we recorded the PLR of 25 adult participants to light flashes generated by the screen set-up as well as by a conventional LED set-up. PLR parameters relating to parasympathetic and sympathetic activity were calculated from the pupil responses. We tested the split-half reliability across two consecutive blocks of trials, and the relationships between the parameters of PLRs evoked by the two set-ups. Participants rated their need for recovery prior to the PLR recordings. Results: PLR parameters acquired in the screen and LED set-ups showed good reliability for amplitude related parameters. The PLRs evoked by both set-ups were consistent, but showed systematic differences in absolute values of all parameters. Additionally, higher need for recovery was associated with faster and larger constriction of the PLR. Conclusions: This study assessed the PLR generated by a computer screen and the PLR generated by a LED. The good reliability within set-ups and the consistency between the PLRs evoked by the set-ups indicate that both systems provides a valid way to evoke the PLR. A higher need for recovery was associated with faster and larger constricting PLRs, suggesting increased levels of parasympathetic nervous system activity in people experiencing higher levels of need for recovery on a daily basis

    Predictors of entering a hearing aid evaluation period: a prospective study in older hearing-help seekers

    Get PDF
    This study aimed to determine the predictors of entering a hearing aid evaluation period (HAEP) using a prospective design drawing on the health belief model and the transtheoretical model. In total, 377 older persons who presented with hearing problems to an ENT-specialist (n = 110) or a hearing aid dispenser (n = 267) filled in a baseline questionnaire. After four months, it was determined via a telephone interview whether or not participants had decided to enter a HAEP. Multivariable logistic regression analyses were applied to determine which baseline variables predicted HAEP status. A priori, candidate predictors were divided into ‘likely’ and ‘novel’ predictors based on the literature. The following variables turned out to be significant predictors: more expected hearing aid benefits, greater social pressure, and greater self-reported hearing disability. In addition, greater hearing loss severity and stigma were predictors in women but not in men. Of note, the predictive effect of self-reported hearing disability was modified by readiness such that with higher readiness, the positive predictive effect became stronger. None of the ‘novel’ predictors added significant predictive value. The results support the notion that predictors of hearing aid uptake are also predictive of entering a HAEP. This study shows that some of these predictors appear to be gender-specific or are dependent on a person’s readiness for change. After assuring the external validity of the predictors, an important next step would be to develop prediction rules for use in clinical practice, so that older persons’ hearing help seeking journey can be facilitated

    Hearing impairment and daily-life fatigue: a qualitative study

    Get PDF
    Objective: Hearing impairment is linked to increased fatigue, yet little is known about the real-world impact of this fatigue. This qualitative study investigated the experience of daily-life fatigue in people with a hearing impairment. Design: Individual face-to-face semi-structured interviews were conducted. Thematic analysis was then used to analyse the data. Study Sample: Fourteen hearing impaired participants (aged 44-70 years) who varied in terms of hearing loss, hearing aid status, age, and gender. Results: The themes and sub-themes that emerged from the transcripts were: Fatigue (effort-driven fatigue, emotion-driven fatigue, breaks and recovery, the perceived relationship between hearing impairment and fatigue and sleep), Effort (cognitive effort and physical effort), Coping Strategies (withdrawal, avoidance and planning), Relationships and Emotions, Hearing Aid Impact. Conclusions: The study highlights that hearing impairment-related fatigue is experienced by many but not all, and to different extents. Hearing aids were weakly linked to a beneficial effect on fatigue. In addition to the more widely researched effort-driven fatigue, participants described fatigue linked to the negative emotions related to having a hearing impairment. These findings, in conjunction with the widespread utilisation of different coping strategies, demonstrate that the experience of fatigue is varied and likely dependent on personal factors and lifestyle

    Impact of stimulus-related factors and hearing impairment on listening effort as indicated by pupil dilation

    Get PDF
    Previous research has reported effects of masker type and signal-to-noise ratio (SNR) on listening effort, as indicated by the peak pupil dilation (PPD) relative to baseline during speech recognition. At about 50% correct sentence recognition performance, increasing SNRs generally results in declining PPDs, indicating reduced effort. However, the decline in PPD over SNRs has been observed to be less pronounced for hearing-impaired (HI) compared to normal-hearing (NH) listeners. The presence of a competing talker during speech recognition generally resulted in larger PPDs as compared to the presence of a fluctuating or stationary background noise. The aim of the present study was to examine the interplay between hearing-status, a broad range of SNRs corresponding to sentence recognition performance varying from 0 to 100% correct, and different masker types (stationary noise and single-talker masker) on the PPD during speech perception. Twenty-five HI and 32 age-matched NH participants listened to sentences across a broad range of SNRs, masked with speech from a single talker (−25 dB to +15 dB SNR) or with stationary noise (−12 dB to +16 dB). Correct sentence recognition scores and pupil responses were recorded during stimulus presentation. With a stationary masker, NH listeners show maximum PPD across a relatively narrow range of low SNRs, while HI listeners show relatively large PPD across a wide range of ecological SNRs. With the single-talker masker, maximum PPD was observed in the mid-range of SNRs around 50% correct sentence recognition performance, while smaller PPDs were observed at lower and higher SNRs. Mixed-model ANOVAs revealed significant interactions between hearing-status and SNR on the PPD for both masker types. Our data show a different pattern of PPDs across SNRs between groups, which indicates that listening and the allocation of effort during listening in daily life environments may be different for NH and HI listeners

    Impact of SNR, masker type and noise reduction processing on sentence recognition performance and listening effort as indicated by the pupil dilation response

    Get PDF
    Recent studies have shown that activating the noise reduction scheme in hearing aids results in a smaller peak pupil dilation (PPD), indicating reduced listening effort, at 50% and 95% correct sentence recognition with a 4-talker masker. The objective of this study was to measure the effect of the noise reduction scheme (on or off) on PPD and sentence recognition across a wide range of signal-to-noise ratios (SNRs) from +16 dB to −12 dB and two masker types (4-talker and stationary noise). Relatively low PPDs were observed at very low (−12 dB) and very high (+16 dB to +8 dB) SNRs presumably due to ‘giving up’ and ‘easy listening’, respectively. The maximum PPD was observed with SNRs at approximately 50% correct sentence recognition. Sentence recognition with both masker types was significantly improved by the noise reduction scheme, which corresponds to the shift in performance from SNR function at approximately 5 dB toward a lower SNR. This intelligibility effect was accompanied by a corresponding effect on the PPD, shifting the peak by approximately 4 dB toward a lower SNR. In addition, with the 4-talker masker, when the noise reduction scheme was active, the PPD was smaller overall than that when the scheme was inactive. We conclude that with the 4-talker masker, noise reduction scheme processing provides a listening effort benefit in addition to any effect associated with improved intelligibility. Thus, the effect of the noise reduction scheme on listening effort incorporates more than can be explained by intelligibility alone, emphasizing the potential importance of measuring listening effort in addition to traditional speech reception measures

    Listening efficiency in adult cochlear-implant users compared with normally-hearing controls at ecologically relevant signal-to-noise ratios

    Get PDF
    Introduction: Due to having to work with an impoverished auditory signal, cochlear-implant (CI) users may experience reduced speech intelligibility and/or increased listening effort in real-world listening situations, compared to their normally-hearing (NH) peers. These two challenges to perception may be usefully integrated in a measure of listening efficiency: conceptually, the amount of accuracy achieved for a certain amount of effort expended. Methods: We describe a novel approach to quantifying listening efficiency based on the rate of evidence accumulation toward a correct response in a linear ballistic accumulator (LBA) model of choice decision-making. Estimation of this objective measure within a hierarchical Bayesian framework confers further benefits, including full quantification of uncertainty in parameter estimates. We applied this approach to examine the speech-in-noise performance of a group of 24 CI users (M age: 60.3, range: 20–84 years) and a group of 25 approximately age-matched NH controls (M age: 55.8, range: 20–79 years). In a laboratory experiment, participants listened to reverberant target sentences in cafeteria noise at ecologically relevant signal-to-noise ratios (SNRs) of +20, +10, and +4 dB SNR. Individual differences in cognition and self-reported listening experiences were also characterised by means of cognitive tests and hearing questionnaires. Results: At the group level, the CI group showed much lower listening efficiency than the NH group, even in favourable acoustic conditions. At the individual level, within the CI group (but not the NH group), higher listening efficiency was associated with better cognition (i.e., working-memory and linguistic-closure) and with more positive self-reported listening experiences, both in the laboratory and in daily life. Discussion: We argue that listening efficiency, measured using the approach described here, is: (i) conceptually well-motivated, in that it is theoretically impervious to differences in how individuals approach the speed-accuracy trade-off that is inherent to all perceptual decision making; and (ii) of practical utility, in that it is sensitive to differences in task demand, and to differences between groups, even when speech intelligibility remains at or near ceiling level. Further research is needed to explore the sensitivity and practical utility of this metric across diverse listening situations

    Hopes and Fears: Community cohesion and the ‘White working class’ in one of the ‘failed spaces’ of multiculturalism

    Get PDF
    Since 2001, community cohesion has been an English policy concern, with accompanying media discourse portraying a supposed failure by Muslims to integrate. Latterly, academia has foregrounded White majority attitudes towards ethnic diversity, particularly those of the ‘White working class’. Whilst questioning this categorisation, we present data on attitudes towards diversity from low income, mainly White areas within Dewsbury, West Yorkshire, a town portrayed in media discourse as one of the ‘failed spaces’ of multiculturalism. Drawing on mixed methods research, we present and discuss data that provide a complex message, seemingly confirming pessimistic analyses around ethnic diversity and predominantly White neighbourhoods but also highlighting an appetite within the same communities for greater and more productive inter-ethnic contact. Furthermore, anxieties about diversity and integration have largely failed to coalesce into broad support for organised anti-minority politics manifest in groups such as the English Defence League

    Ovine pedomics : the first study of the ovine foot 16S rRNA-based microbiome

    Get PDF
    We report the first study of the bacterial microbiome of ovine interdigital skin based on 16S rRNA by pyrosequencing and conventional cloning with Sanger-sequencing. Three flocks were selected, one a flock with no signs of footrot or interdigital dermatitis, a second flock with interdigital dermatitis alone and a third flock with both interdigital dermatitis and footrot. The sheep were classified as having either healthy interdigital skin (H), interdigital dermatitis (ID) or virulent footrot (VFR). The ovine interdigital skin bacterial community varied significantly by flock and clinical condition. The diversity and richness of operational taxonomic units was greater in tissue from sheep with ID than H or VFR affected sheep. Actinobacteria, Bacteriodetes, Firmicutes and Proteobacteria were the most abundant phyla comprising 25 genera. Peptostreptococcus, Corynebacterium and Staphylococcus were associated with H, ID and VFR respectively. Sequences of Dichelobacter nodosus, the causal agent of ovine footrot, were not amplified due to mismatches in the 16S rRNA universal forward primer (27F). A specific real time PCR assay was used to demonstrate the presence of D. nodosus which was detected in all samples including the flock with no signs of ID or VFR. Sheep with ID had significantly higher numbers of D. nodosus (104-109 cells/g tissue) than those with H or VFR feet

    Cigarette smoking among school-going adolescents in Lithuania: Results from the 2005 Global Youth Tobacco Survey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The majority of people who suffer morbidity due to smoking may have initiated smoking during adolescent period. The aim of this study is to determine the prevalence and associated factors for cigarette smoking among school-going adolescents in Lithuania.</p> <p>Findings</p> <p>Data from the Global Youth Tobacco Survey (GYTS) 2005 were used to conduct this study. Data were analyzed using SUDAAN software 9.03. Comparisons for categorical variables were done using the Pearson's Chi-square test. The cut of point for statistical significance was set at 5% level. Logistic regression analyses were conducted to determine factors associated with the outcome. Unadjusted odds ratios (OR) and adjusted odds ratios (AOR) together with their 95% confidence intervals (CI) are reported.</p> <p>Of the 1822 respondents, 35.8% males and 27.1% females reported being current cigarette smokers (p < 0.001). Having friends who smoke cigarettes was associated with smoking after controlling for age, gender, parental smoking status, and perception of risks of smoking (AOR = 3.76; 95% CI [2.33, 6.90] for some friends using tobacco; and AOR = 17.18; 95% CI [10.46, 28.21] for most or all friends using tobacco). Male gender and having one or both parents who smoke cigarettes were associated with smoking (AOR = 1.31; 95% CI [1.03, 1.66]) and AOR = 1.76; 95% CI [1.37, 2.27]) respectively).</p> <p>Conclusions</p> <p>There is a high prevalence of cigarette smoking among Lithuanian adolescents. Male adolescents and adolescents who have friends or parents who smoke should be the main target for tobacco control in Lithuania.</p

    The systematic guideline review: method, rationale, and test on chronic heart failure

    Get PDF
    Background: Evidence-based guidelines have the potential to improve healthcare. However, their de-novo-development requires substantial resources-especially for complex conditions, and adaptation may be biased by contextually influenced recommendations in source guidelines. In this paper we describe a new approach to guideline development-the systematic guideline review method (SGR), and its application in the development of an evidence-based guideline for family physicians on chronic heart failure (CHF). Methods: A systematic search for guidelines was carried out. Evidence-based guidelines on CHF management in adults in ambulatory care published in English or German between the years 2000 and 2004 were included. Guidelines on acute or right heart failure were excluded. Eligibility was assessed by two reviewers, methodological quality of selected guidelines was appraised using the AGREE instrument, and a framework of relevant clinical questions for diagnostics and treatment was derived. Data were extracted into evidence tables, systematically compared by means of a consistency analysis and synthesized in a preliminary draft. Most relevant primary sources were re-assessed to verify the cited evidence. Evidence and recommendations were summarized in a draft guideline. Results: Of 16 included guidelines five were of good quality. A total of 35 recommendations were systematically compared: 25/35 were consistent, 9/35 inconsistent, and 1/35 un-rateable (derived from a single guideline). Of the 25 consistencies, 14 were based on consensus, seven on evidence and four differed in grading. Major inconsistencies were found in 3/9 of the inconsistent recommendations. We re-evaluated the evidence for 17 recommendations (evidence-based, differing evidence levels and minor inconsistencies) - the majority was congruent. Incongruity was found where the stated evidence could not be verified in the cited primary sources, or where the evaluation in the source guidelines focused on treatment benefits and underestimated the risks. The draft guideline was completed in 8.5 man-months. The main limitation to this study was the lack of a second reviewer. Conclusion: The systematic guideline review including framework development, consistency analysis and validation is an effective, valid, and resource saving-approach to the development of evidence-based guidelines
    • …
    corecore