1,241 research outputs found

    Evaluation of 3D Technologies In Dentistry

    Get PDF
    Quality of service, in terms of improvement in patient satisfaction, is an increasingly important objective in all medical fields, and is especially imperative in orthodontics due to the high numbers of patients treated. Information technology can provide a meaningful contribution to bettering treatment processes, and we maintain that systems such as CAD, CAM and CAE, although initially conceived for industrial purposes, should be evaluated, studied and customized with a view to use in medicine. The present study aims to evaluate Reverse Engineering (RE) and Rapid Prototyping (RP) in order to define an ideal chain of advanced technological solutions to support the critical processes of orthodontic activity

    Design of a Base-Board for arrays of closely-packed Multi-Anode Photo-Multipliers

    Full text link
    We describe the design of a Base-Board to house Multi-Anode Photo-Multipliers for use in large-area arrays of light sensors. The goals, the design, the results of tests on the prototypes and future developments are presented.Comment: 16 pages, 5 figures, submitted to Nucl. Instrum. and Meth.

    Auditory-Motor Learning during Speech Production in 9-11-Year-Old Children

    Get PDF
    BACKGROUND: Hearing ability is essential for normal speech development, however the precise mechanisms linking auditory input and the improvement of speaking ability remain poorly understood. Auditory feedback during speech production is believed to play a critical role by providing the nervous system with information about speech outcomes that is used to learn and subsequently fine-tune speech motor output. Surprisingly, few studies have directly investigated such auditory-motor learning in the speech production of typically developing children. METHODOLOGY/PRINCIPAL FINDINGS: In the present study, we manipulated auditory feedback during speech production in a group of 9-11-year old children, as well as in adults. Following a period of speech practice under conditions of altered auditory feedback, compensatory changes in speech production and perception were examined. Consistent with prior studies, the adults exhibited compensatory changes in both their speech motor output and their perceptual representations of speech sound categories. The children exhibited compensatory changes in the motor domain, with a change in speech output that was similar in magnitude to that of the adults, however the children showed no reliable compensatory effect on their perceptual representations. CONCLUSIONS: The results indicate that 9-11-year-old children, whose speech motor and perceptual abilities are still not fully developed, are nonetheless capable of auditory-feedback-based sensorimotor adaptation, supporting a role for such learning processes in speech motor development. Auditory feedback may play a more limited role, however, in the fine-tuning of children's perceptual representations of speech sound categories

    Bracket base remnants after orthodontic debonding

    Get PDF
    Objective: To evaluate whether the debonding procedure leads to restitutio ad integrum of the enamel surface by investigating the presence of enamel within the bracket base remnants after debonding. Materials and Methods: Sixty patients who completed orthodontic treatment with fixed appliances were included. A total of 1068 brackets were microphotographed; the brackets presenting some remnants on the base (n \u200a=\u200a 818) were selected and analyzed with ImageJ software to measure the remnant area. From this population a statistically significant sample (n \u200a=\u200a 100) was observed under a scanning electron microscope to check for the presence of enamel within the remnants. Energy dispersive x-ray spectrometry was also performed to obtain quantitative data. Results: Statistically significant differences in the remnant percentage between arches were observed for incisor and canine brackets (P < .0001 and P \u200a=\u200a .022, respectively). From a morphologic analysis of the scanning electron micrographs the bracket bases were categorized in 3 groups: group A, bases presenting a thin enamel coat (83%); group B, bases showing sizable enamel fragments (7%); group C, bases with no morphologic evidence of enamel presence (10%). Calcium presence was noted on all evaluated brackets under energy dispersive x-ray spectrometry. No significant difference was observed in the Ca/Si ratio between group A (16.21%) and group B (18.77%), whereas the Ca/Si ratio in group C (5.40%) was significantly lower than that of the other groups (P < .323 and P \u200a=\u200a .0001, respectively). Conclusion: The objective of an atraumatic debonding is not achieved yet; in some cases the damage could be clinically relevant

    The use of the laser confocal scanning microscopy to measure resin remnants on customized lingual bracket

    Get PDF
    Background: The study aimed to evaluate the permanence of resin and enamel remains on lingual brackets at the end of orthodontic treatment and after the debonding procedure. The evaluation of resin remnants on customized lingual brackets bases has never done before in other studies because they are curved, and traditional techniques are not applicable. Methods: The sample consisted of 100 lingual brackets (25 incisors, 25 canines, 25 premolars, 25 molars) scanned with a confocal laser microscope (OLS4000). We measured the brackets' surface and the area of resin remnants with the software of the microscope. Median and quartiles were presented to describe the data. ARI calculation was indirect for each tooth, measuring the resin remnants to the total surface of the bracket. The Kruskal-Wallis test and Fisher test were applied respectively to compare the percentages of remnants and the frequencies of the ARI between the four groups. Results: After the analyses, 13 brackets had no adhesive remnants (ARI 0), 29 brackets had less than 50% of resin remnants (ARI 1), 50 brackets had more than 50% of resin remnants (ARI 2), and 8 brackets had 100% of adhesive (ARI 3). Canines brackets presented the lower amount of resin followed by premolars, incisors, and molars. Conclusion: Lingual brackets showed a high frequency of ARI = 2. The median percentage of the bracket surface covered by resin was 41%. We observed a slight tendency of more resin remnants on molar brackets, due to half-pad configuration. The authors suggest paying attention during the debonding procedure of molar brackets since a stronger connection between the adhesive and the bracket mesh means a higher risk of enamel damage

    Analysis of antenal sensilla patterns of Rhodnius prolixus from Colombia and Venezuela

    Get PDF
    Antennal sensilla patterns were used to analyze population variation of domestic Rhodnius prolixus from six departments and states representing three biogeographical regions of Colombia and Venezuela. Discriminant analysis of the patterns of mechanoreceptors and of three types of chemoreceptors on the pedicel and flagellar segments showed clear differentiation between R. prolixus populations east and west of the Andean Cordillera. The distribution of thick and thin-walled trichoids on the second flagellar segment also showed correlation with latitude, but this was not seen in the patterns of other sensilla. The results of the sensilla patterns appear to be reflecting biogeographic features or population isolation rather than characters associated with different habitats and lend support to the idea that domestic R. prolixus originated in the eastern region of the Andes.Fil: Esteban, Lyda. Universidad Industrial de Santander; ColombiaFil: Angulo, VĂ­ctor Manuel. Universidad Industrial de Santander; ColombiaFil: Dora Feliciangeli, M.. Universidad de Carabobo; VenezuelaFil: Catala, Silvia Susana. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro Regional de Investigaciones CientĂ­ficas y Transferencia TecnolĂłgica de La Rioja. - Universidad Nacional de La Rioja. Centro Regional de Investigaciones CientĂ­ficas y Transferencia TecnolĂłgica de La Rioja. - Universidad Nacional de Catamarca. Centro Regional de Investigaciones CientĂ­ficas y Transferencia TecnolĂłgica de La Rioja. - SecretarĂ­a de Industria y MinerĂ­a. Servicio GeolĂłgico Minero Argentino. Centro Regional de Investigaciones CientĂ­ficas y Transferencia TecnolĂłgica de La Rioja. - Provincia de La Rioja. Centro Regional de Investigaciones CientĂ­ficas y Transferencia TecnolĂłgica de La Rioja; Argentin

    Extreme Energy Cosmic Rays (EECR) Observation Capabilities of an "Airwatch from Space'' Mission

    Get PDF
    The longitudinal development and other characteristics of the EECR induced atmospheric showers can be studied from space by detecting the fluorescence light induced in the atmospheric nitrogen. According to the Airwatch concept a single fast detector can be used for measuring both intensity and time development of the streak of fluorescence light produced by the atmospheric shower induced by an EECR. In the present communication the detection capabilities for the EECR observation from space are discussed.Comment: 3 pages (LaTeX). To appear in the Proceedings of TAUP'9

    Stress distribution patterns at mini-implant site during retraction and intrusion - a three-dimensional finite element study

    Get PDF
    Abstract Background The purpose of this study was to evaluate the stress patterns produced in mini-implant and alveolar bone, for various implant dimensions, under different directions of simulated orthodontic force, using a three-dimensional finite element method. Methods Eight finite element (FE) models of mini-implant and bone were generated with insertion angles of 30° and 60°, diameters of 1 and 1.3 mm, and lengths of 6 and 8 mm. A simulated constant orthodontic force of 2 N was applied to each of these FE models in three directions simulating anterior retraction, anterior intrusion and retraction, and molar intrusion. Results Comparison of the maximum von Mises stress in the mini-implant showed that the 1-mm diameter produced significantly high stress, and the amount of stress produced was more for a mini-implant inserted at an angle of 60°. The cortical bone showed that high stresses were generated for the 1-mm-diameter mini-implant and on increasing the insertion angulation from 30° to 60°, the stress produced increased as well. The comparison of von Mises stress in the cancellous bone was insignificant as the amount of stress transmitted was very low. Conclusions The 1-mm-diameter mini-implants are not safe to be used clinically for orthodontic anchorage. The 1.3 × 6 mm dimension mini-implants are recommended for use during anterior segment retraction and during simultaneous intrusion and retraction, and the 1.3 × 8 mm dimension mini-implant is recommended for use during molar intrusion. All mini-implants should be inserted at a 30° angle into the bone for reduced stress and improved stability

    Search for charginos in e+e- interactions at sqrt(s) = 189 GeV

    Full text link
    An update of the searches for charginos and gravitinos is presented, based on a data sample corresponding to the 158 pb^{-1} recorded by the DELPHI detector in 1998, at a centre-of-mass energy of 189 GeV. No evidence for a signal was found. The lower mass limits are 4-5 GeV/c^2 higher than those obtained at a centre-of-mass energy of 183 GeV. The (\mu,M_2) MSSM domain excluded by combining the chargino searches with neutralino searches at the Z resonance implies a limit on the mass of the lightest neutralino which, for a heavy sneutrino, is constrained to be above 31.0 GeV/c^2 for tan(beta) \geq 1.Comment: 22 pages, 8 figure
    • 

    corecore