4,364 research outputs found
The DL Advocate: Playing the devil's advocate with hidden systematic uncertainties
We propose a new method based on machine learning to play the devil's
advocate and investigate the impact of unknown systematic effects in a
quantitative way. This method proceeds by reversing the measurement process and
using the physics results to interpret systematic effects under the Standard
Model hypothesis. We explore this idea with two alternative approaches, one
relies on a combination of gradient descent and optimisation techniques, the
other employs reinforcement learning. We illustrate the potentiality of the
presented method by considering two examples, firstly the case of a branching
fraction measurement of a particle decay and secondly the determination of the
angular observable in decays. We find
that for the former, the size of a hypothetical hidden systematic uncertainty
strongly depends on the kinematic overlap between the signal and normalisation
channel, while the latter is very robust against possible mismodellings of the
efficiency.Comment: 21 pages, 7 figure
The DL Advocate: playing the devil’s advocate with hidden systematic uncertainties
We propose a new method based on machine learning to play the devil’s advocate and investigate the impact of unknown systematic effects in a quantitative way. This method proceeds by reversing the measurement process and using the physics results to interpret systematic effects under the Standard Model hypothesis. We explore this idea with two alternative approaches: the first one relies on a combination of gradient descent and optimisation techniques, its application and potentiality is illustrated with an example that studies the branching fraction measurement of a heavy-flavour decay. The second method employs reinforcement learning and it is applied to the determination of the angular observable in decays. We find that for the former, the size of a hypothetical hidden systematic uncertainty strongly depends on the kinematic overlap between the signal and normalisation channel, while the latter is very robust against possible mismodellings of the efficiency
Status Report of the DPHEP Study Group: Towards a Global Effort for Sustainable Data Preservation in High Energy Physics
Data from high-energy physics (HEP) experiments are collected with
significant financial and human effort and are mostly unique. An
inter-experimental study group on HEP data preservation and long-term analysis
was convened as a panel of the International Committee for Future Accelerators
(ICFA). The group was formed by large collider-based experiments and
investigated the technical and organisational aspects of HEP data preservation.
An intermediate report was released in November 2009 addressing the general
issues of data preservation in HEP. This paper includes and extends the
intermediate report. It provides an analysis of the research case for data
preservation and a detailed description of the various projects at experiment,
laboratory and international levels. In addition, the paper provides a concrete
proposal for an international organisation in charge of the data management and
policies in high-energy physics
Dark sectors 2016 Workshop: community report
This report, based on the Dark Sectors workshop at SLAC in April 2016,
summarizes the scientific importance of searches for dark sector dark matter
and forces at masses beneath the weak-scale, the status of this broad
international field, the important milestones motivating future exploration,
and promising experimental opportunities to reach these milestones over the
next 5-10 years
Efficiency of Finding Muon Track Trigger Primitives in CMS Cathode Strip Chambers
In the CMS Experiment, muon detection in the forward direction is accomplished by cathode strip chambers~(CSC). These detectors identify muons, provide a fast muon trigger, and give a precise measurement of the muon trajectory. There are 468 six-plane CSCs in the system. The efficiency of finding muon trigger primitives (muon track segments) was studied using~36 CMS CSCs and cosmic ray muons during the Magnet Test and Cosmic Challenge~(MTCC) exercise conducted by the~CMS experiment in~2006. In contrast to earlier studies that used muon beams to illuminate a very small chamber area (~m), results presented in this paper were obtained by many installed CSCs operating {\em in situ} over an area of ~m as a part of the~CMS experiment. The efficiency of finding 2-dimensional trigger primitives within 6-layer chambers was found to be~. These segments, found by the CSC electronics within ~ns after the passing of a muon through the chambers, are the input information for the Level-1 muon trigger and, also, are a necessary condition for chambers to be read out by the Data Acquisition System
Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter
The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS
Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4
The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile
Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters
Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%
Energy Resolution Performance of the CMS Electromagnetic Calorimeter
The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals
Measurement of the forward Z boson production cross-section in pp collisions at TeV
A measurement of the production cross-section of Z bosons in pp collisions at TeV is presented using dimuon and dielectron final states in LHCb data. The cross-section is measured for leptons with pseudorapidities in the range , transverse momenta GeV and dilepton invariant mass in the range GeV. The integrated cross-section from averaging the two final states is \begin{equation*}\sigma_{\text{Z}}^{\ell\ell} = 194.3 \pm 0.9 \pm 3.3 \pm 7.6\text{ pb,}\end{equation*} where the first uncertainty is statistical, the second is due to systematic effects, and the third is due to the luminosity determination. In addition, differential cross-sections are measured as functions of the Z boson rapidity, transverse momentum and the angular variable
- …
