166 research outputs found

    Mid-Infrared Instrumentation for the European Extremely Large Telescope

    Full text link
    MIDIR is the proposed thermal/mid-IR imager and spectrograph for the European Extremely Large Telescope (E-ELT). It will cover the wavelength range of 3 to at least 20 microns. Designed for diffraction-limited performance over the entire wavelength range, MIDIR will require an adaptive optics system; a cryogenically cooled system could offer optimal performance in the IR, and this is a critical aspect of the instrument design. We present here an overview of the project, including a discussion of MIDIR's science goals and a comparison with other infrared (IR) facilities planned in the next decade; top level requirements derived from these goals are outlined. We describe the optical and mechanical design work carried out in the context of a conceptual design study, and discuss some important issues to emerge from this work, related to the design, operation and calibration of the instrument. The impact of telescope optical design choices on the requirements for the MIDIR instrument is demonstrated.Comment: for publication in SPIE Proceedings vol. 6692, Cryogenic Optical Systems and Instrumentation XII, eds. J.B. Heaney and L.G. Burriesci, San Diego, Aug 200

    Wavelength calibration of the JWST-MIRI medium resolution spectrometer

    Full text link
    We present the wavelength and spectral resolution characterisation of the Integral Field Unit (IFU) Medium Resolution Spectrometer for the Mid-InfraRed Instrument (MIRI), to fly onboard the James Webb Space Telescope in 2014. We use data collected using the Verification Model of the instrument and develop an empirical method to calibrate properties such as wavelength range and resolving power in a portion of the spectrometer's full spectral range (5-28 microns). We test our results against optical models to verify the system requirements and combine them with a study of the fringing pattern in the instrument's detector to provide a more accurate calibration. We show that MIRI's IFU spectrometer will be able to produce spectra with a resolving power above R=2800 in the wavelength range 6.46-7.70 microns, and that the unresolved spectral lines are well fitted by a Gaussian profile.Comment: 12 pages, submitted to SPIE Proceedings vol. 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wav

    Polymer electrolytes based on modified natural rubber

    Get PDF
    Modified natural rubber polymer hosts having low transition glass temperatures have been investigated for use in polymer electrolytes. Two types of modified natural rubber, namely 25% epoxidised natural rubber (ENR-25) and 50% epoxidised natural rubber (ENR-50) were employed in conjunction with poly(ethylene oxide), PEO. Results are reported for ionic conductivity and thermal properties for both unplasticized and plasticized polymer electrolyte systems with lithium triflate. The samples were in the form of free standing films with the thickness 0.2–0.5 mm and mixtures of ethylene carbonate (EC) and propylene carbonate (PC) were used as plasticizers. Unplasticized modified natural rubber-based systems exhibit ionic conductivities in the range 10−6 to 10−5 S cm−1 at ambient temperatures. Incorporating 100% of EC/PC by weight fraction of polymer (ENR/PEO) to the systems yielded mechanically stable films and ionic conductivities in the range of 10−4 S cm−1 at ambient temperature

    Optical performance of the JWST MIRI flight model: characterization of the point spread function at high-resolution

    Get PDF
    The Mid Infra Red Instrument (MIRI) is one of the four instruments onboard the James Webb Space Telescope (JWST), providing imaging, coronagraphy and spectroscopy over the 5-28 microns band. To verify the optical performance of the instrument, extensive tests were performed at CEA on the flight model (FM) of the Mid-InfraRed IMager (MIRIM) at cryogenic temperatures and in the infrared. This paper reports on the point spread function (PSF) measurements at 5.6 microns, the shortest operating wavelength for imaging. At 5.6 microns the PSF is not Nyquist-sampled, so we use am original technique that combines a microscanning measurement strategy with a deconvolution algorithm to obtain an over-resolved MIRIM PSF. The microscanning consists in a sub-pixel scan of a point source on the focal plane. A data inversion method is used to reconstruct PSF images that are over-resolved by a factor of 7 compared to the native resolution of MIRI. We show that the FWHM of the high-resolution PSFs were 5-10% wider than that obtained with Zemax simulations. The main cause was identified as an out-of-specification tilt of the M4 mirror. After correction, two additional test campaigns were carried out, and we show that the shape of the PSF is conform to expectations. The FWHM of the PSFs are 0.18-0.20 arcsec, in agreement with simulations. 56.1-59.2% of the total encircled energy (normalized to a 5 arcsec radius) is contained within the first dark Airy ring, over the whole field of view. At longer wavelengths (7.7-25.5 microns), this percentage is 57-68%. MIRIM is thus compliant with the optical quality requirements. This characterization of the MIRIM PSF, as well as the deconvolution method presented here, are of particular importance, not only for the verification of the optical quality and the MIRI calibration, but also for scientific applications.Comment: 13 pages, submitted to SPIE Proceedings vol. 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wav

    The Origin of the Silicate Emission Features in the Seyfert 2 Galaxy, NGC 2110

    Full text link
    The unified model of active galactic nuclei (AGN) predicts silicate emission features at 10 and 18 microns in type 1 AGN, and such features have now been observed in objects ranging from distant QSOs to nearby LINERs. More surprising, however, is the detection of silicate emission in a few type 2 AGN. By combining Gemini and Spitzer mid-infrared imaging and spectroscopy of NGC 2110, the closest known Seyfert 2 galaxy with silicate emission features, we can constrain the location of the silicate emitting region to within 32 pc of the nucleus. This is the strongest constraint yet on the size of the silicate emitting region in a Seyfert galaxy of any type. While this result is consistent with a narrow line region origin for the emission, comparison with clumpy torus models demonstrates that emission from an edge-on torus can also explain the silicate emission features and 2-20 micron spectral energy distribution of this object. In many of the best-fitting models the torus has only a small number of clouds along the line of sight, and does not extend far above the equatorial plane. Extended silicate-emitting regions may well be present in AGN, but this work establishes that emission from the torus itself is also a viable option for the origin of silicate emission features in active galaxies of both type 1 and type 2.Comment: ApJL, accepte

    The Mid-Infrared Instrument for the James Webb Space Telescope, V: Predicted Performance of the MIRI Coronagraphs

    Full text link
    The imaging channel on the Mid-Infrared Instrument (MIRI) is equipped with four coronagraphs that provide high contrast imaging capabilities for studying faint point sources and extended emission that would otherwise be overwhelmed by a bright point-source in its vicinity. Such bright sources might include stars that are orbited by exoplanets and circumstellar material, mass-loss envelopes around post-main-sequence stars, the near-nuclear environments in active galaxies, and the host galaxies of distant quasars. This paper describes the coronagraphic observing modes of MIRI, as well as performance estimates based on measurements of the MIRI flight model during cryo-vacuum testing. A brief outline of coronagraphic operations is also provided. Finally, simulated MIRI coronagraphic observations of a few astronomical targets are presented for illustration

    Dust in the inner regions of debris disks around A stars

    Get PDF
    We present infrared interferometric observations of the inner regions of two A-star debris disks, beta Leo and zeta Lep, using the FLUOR instrument at the CHARA interferometer on both short (30 m) and long (>200 m) baselines. For the target stars, the short baseline visibilities are lower than expected for the stellar photosphere alone, while those of a check star, delta Leo, are not. We interpret this visibility offset of a few percent as a near-infrared excess arising from dust grains which, due to the instrumental field of view, must be located within several AU of the central star. For beta Leo, the near-infrared excess producing grains are spatially distinct from the dust which produces the previously known mid-infrared excess. For zeta Lep, the near-infrared excess may be spatially associated with the mid-infrared excess producing material. We present simple geometric models which are consistent with the near and mid-infrared excess and show that for both objects, the near-infrared producing material is most consistent with a thin ring of dust near the sublimation radius with typical grain sizes smaller than the nominal radiation pressure blowout radius. Finally, we discuss possible origins of the near-infrared emitting dust in the context of debris disk evolution models.Comment: 20 pages, 2 figures, to appear in the Astrophysical Journa

    E-ELT/METIS

    Full text link
    The Mid-infrared E-ELT Imager and Spectrograph (METIS) will be one of the first three scientific instruments on the European Extremely Large Telescope (E-ELT). It will be the only instrument to cover the thermal/mid-infrared wavelength range from 3-19 μm. METIS offers a number of scientifically important observing modes, including diffraction-limited imaging, low resolution slit spectroscopy, coronagraphy, and high resolution (R ˜ 100,000) integral field spectroscopy at very high sensitivity. This paper gives a brief summary of METIS and focuses on its unique discovery space in the area of protoplanetary disks, where METIS is quite complementary to ALMA and JWST

    The Mid-infrared E-ELT Imager and Spectrograph (METIS)

    Get PDF
    METIS will be among the first generation of scientific instruments on the E-ELT. Focusing on highest angular resolution and high spectral resolution, METIS will provide diffraction limited imaging and coronagraphy from 3-14um over an 20"x20" field of view, as well as integral field spectroscopy at R ~ 100,000 from 2.9-5.3um. In addition, METIS provides medium-resolution (R ~ 5000) long slit spectroscopy, and polarimetric measurements at N band. While the baseline concept has already been discussed, this paper focuses on the significant developments over the past two years in several areas: The science case has been updated to account for recent progress in the main science areas circum-stellar disks and the formation of planets, exoplanet detection and characterization, Solar system formation, massive stars and clusters, and star formation in external galaxies. We discuss the developments in the adaptive optics (AO) concept for METIS, the telescope interface, and the instrument modelling. Last but not least, we provide an overview of our technology development programs, which ranges from coronagraphic masks, immersed gratings, and cryogenic beam chopper to novel approaches to mirror polishing, background calibration and cryo-cooling. These developments have further enhanced the design and technology readiness of METIS to reliably serve as an early discovery machine on the E-ELT.Comment: 18 pages, 14 figures, paper presented at the conference 'Astronomical Telescopes and Instrumentation' in Montreal (2014

    Evidence for an Edge-On Disk around the Young Star MWC 778 from Infrared Imaging and Polarimetry

    Full text link
    MWC 778 is an unusual and little-studied young stellar object located in the IC 2144 nebula. Recent spectroscopy by Herbig and Vacca (2008) suggested the presence of an edge-on circumstellar disk around it. We present near-infrared adaptive optics imaging polarimetry and mid-infrared imaging which directly confirm the suspected nearly-edge-on disk around MWC 778 (i ~ 70-80 degrees) plus reveal a more extensive envelope pierced by bipolar outflow cavities. In addition, our mid-infrared images and near-infrared polarization maps detect a spiral-shaped structure surrounding MWC 778, with arms that extend beyond 6" on either side of the star. Although MWC 778 has previously been classified as an Herbig Ae/Be star, the properties of its central source (including its spectral type) remain fairly uncertain. Herbig & Vacca (2008) suggested an F or G spectral type based on the presence of metallic absorption lines in the optical spectrum, which implies that MWC 778 may belong to the fairly rare class of Intermediate-Mass T Tauri Stars (IMTTSs) which are the evolutionary precursors to Herbig Ae/Be objects. Yet its integrated bolometric luminosity, > 750 L_sun (for an assumed distance of 1 kpc) is surprisingly high for an F or G spectral type, even for an IMTTS. We speculate on several possible explanations for this discrepancy, including its true distance being much closer than 1 kpc, the presence of a binary companion, and/or a non-stellar origin for the observed absorption lines.Comment: Accepted to AJ. 11 pages, 3 figure
    corecore